Mizoram Sorkar chuan Bairabi to Sairang BG Railway Line leh Rail Station a siam tur leh zauh tur chungchanga Social Impact Assessment Report leh Expert Group te recommendation te chu a hnuaia tarlan tehfung hmang hian ngun takin a en
The Mizoram Gazette EXTRA ORDINARY Published by Authority RNI No. 27009/1973 Postal Regn. No. NE-313(MZ) 2006-2008VOL - XLVI Aizawl, Friday 10.3.2017 Phalguna 17, S.E. 1938, Issue No. 105 NOTIFICATIONNo.K.12011/26(A)/2011-REV, the 2nd March, 2017.Mizoram (Land Acquisition, Rehabilita- tion & Resettlement) Act, 2016 hnuaia Section 8 (1)(2)(3) in a phut angin Mizoram Sorkar chuan Bairabi to Sairang BG Railway Line leh Rail Station a siam tur leh zauh tur chungchanga Social Impact Assessment Report leh Expert Group te recommendation te chu a hnuaia tarlan tehfung hmang hian ngun takin a en chhuak a : 1.He Bairabi to Sairang BG Railway Line leh Rail Station a siam tur leh zauh tur hi mipui tana thil tha leh tangkai tur a nih avangin a nghawng tur khuaa mipuite ram thahnem tak laksak a tul dawn a ni. 2.SIA Report in a tarlan angin he ruahmanna in nghawng tha a neih turte hi nghawng thalo a neih tur aiin a thahnem zawk hle a ni. 3.Ram laksak tur hi mamawh tlem thei ang ber a ni. 4.Heng lai hmunah hian ram lak tawh hman lova dah mai mai a awm lo. Mizoram Sorkar chuan he kawngin a paltlang a mi chengte tibuai lo thei ang ber leh khawtlang thil tichhe lo thei ang ber in leh ramsa, thing leh mau bakah mimal tinte tawrhna thlen lo thei ang bera hma la chungin heng Aizawl leh Kolasib District a Bairabi to Sairang BG Railway Line leh Rail Station a siam tur leh a zauh tur in a nghawng khua a mimal ram engemawzat lek (acquire) a tum a ni. Hei hi a nghawng tur mimal leh vantlang bakah he thila chanvo neitu (stakeholders) zawng zawngte lo hriat atan puanzar a ni e. Lalram Thanga, Principal to the Govt. of Mizoram, Land Revenue & Settlement Deptt. Published and Issued by the Controller, Printing & Stationery, Mizoram Printed at the Mizoram Government Press, Aizawl C-50
The Mizoram Gazette EXTRA ORDINARY Published by Authority RNI No. 27009/1973 Postal Regn. No. NE-313(MZ) 2006-2008VOL - XLVI Aizawl, Friday 10.3.2017 Phalguna 17, S.E. 1938, Issue No. 105 NOTIFICATIONNo.K.12011/26(A)/2011-REV, the 2nd March, 2017.Mizoram (Land Acquisition, Rehabilita- tion & Resettlement) Act, 2016 hnuaia Section 8 (1)(2)(3) in a phut angin Mizoram Sorkar chuan Bairabi to Sairang BG Railway Line leh Rail Station a siam tur leh zauh tur chungchanga Social Impact Assessment Report leh Expert Group te recommendation te chu a hnuaia tarlan tehfung hmang hian ngun takin a en chhuak a : 1.He Bairabi to Sairang BG Railway Line leh Rail Station a siam tur leh zauh tur hi mipui tana thil tha leh tangkai tur a nih avangin a nghawng tur khuaa mipuite ram thahnem tak laksak a tul dawn a ni. 2.SIA Report in a tarlan angin he ruahmanna in nghawng tha a neih turte hi nghawng thalo a neih tur aiin a thahnem zawk hle a ni. 3.Ram laksak tur hi mamawh tlem thei ang ber a ni. 4.Heng lai hmunah hian ram lak tawh hman lova dah mai mai a awm lo. Mizoram Sorkar chuan he kawngin a paltlang a mi chengte tibuai lo thei ang ber leh khawtlang thil tichhe lo thei ang ber in leh ramsa, thing leh mau bakah mimal tinte tawrhna thlen lo thei ang bera hma la chungin heng Aizawl leh Kolasib District a Bairabi to Sairang BG Railway Line leh Rail Station a siam tur leh a zauh tur in a nghawng khua a mimal ram engemawzat lek (acquire) a tum a ni. Hei hi a nghawng tur mimal leh vantlang bakah he thila chanvo neitu (stakeholders) zawng zawngte lo hriat atan puanzar a ni e. Lalram Thanga, Principal to the Govt. of Mizoram, Land Revenue & Settlement Deptt. Published and Issued by the Controller, Printing & Stationery, Mizoram Printed at the Mizoram Government Press, Aizawl C-50Construction of Bairabi to Sairang Railway BG Line by Northern Frontier Railways
The Mizoram Gazette EXTRA ORDINARY Published by Authority RNI No. 27009/1973 Postal Regn. No. NE-313(MZ) 2006-2008VOL - XLVI Aizawl, Friday 10.3.2017 Phalguna 17, S.E. 1938, Issue No. 106 NOTIFICATIONNo.K.12011/26(B)/2011-REV, the 2nd March, 2017.Whereas it appears to the Government of Mizoram that a total of 7.68 acres of land is required in the villages of Mualkhang in the District of Kolasib for public purpose, viz, Bairabi-Sairang Railway BG Line Project.Social Impact Assessment Study was carried out by State Institute of Rural Development & Panchayati Raj (SIRD & PR) and a report submitted as per Section 4 of the Mizoram (Land Acquisition, Rehabilitation & Resettlement) Act, 2016 (copy of SIA Report appended at Annexure-II). A total of 106 families are likely to be affected due to the land acquisition. The reason necessitating such affect is given below: “Construction of Bairabi to Sairang Railway BG Line by Northern Frontier Railways” Therefore, it is notified that for the above said project in the villages of the District of Kolasib land measuring 7.68 acres is under acquisition. This notification is made under the provisions of Section 11 (1) of the Mizoram (Land Acquisition, Rehabilitation & Resettlement) Act, 2016, to all whom it may concern. A plan of the land may be inspected in the office of the District Collector and Settlement Officer of concerned District on any working day during working hours. Objections, if any, to the acquisition regarding: iv)The area and suitability of land proposed to be acquired. v)Justification offered for public purpose. vi)The findings of the Social Impact Assessment Report. may be filed by the person interested within 60 (sixty) days from the date of publication of this notification as provided under Section 15 of the Act before the District Collector, Kolasib District. Lalram Thanga, Principal to the Govt. of Mizoram, Land Revenue & Settlement Deptt. Published and Issued by the Controller, Printing & Stationery, Mizoram Printed at the Mizoram Government Press, Aizawl C-50
The Mizoram Gazette EXTRA ORDINARY Published by Authority RNI No. 27009/1973 Postal Regn. No. NE-313(MZ) 2006-2008VOL - XLVI Aizawl, Friday 10.3.2017 Phalguna 17, S.E. 1938, Issue No. 106 NOTIFICATIONNo.K.12011/26(B)/2011-REV, the 2nd March, 2017.Whereas it appears to the Government of Mizoram that a total of 7.68 acres of land is required in the villages of Mualkhang in the District of Kolasib for public purpose, viz, Bairabi-Sairang Railway BG Line Project.Social Impact Assessment Study was carried out by State Institute of Rural Development & Panchayati Raj (SIRD & PR) and a report submitted as per Section 4 of the Mizoram (Land Acquisition, Rehabilitation & Resettlement) Act, 2016 (copy of SIA Report appended at Annexure-II). A total of 106 families are likely to be affected due to the land acquisition. The reason necessitating such affect is given below: “Construction of Bairabi to Sairang Railway BG Line by Northern Frontier Railways” Therefore, it is notified that for the above said project in the villages of the District of Kolasib land measuring 7.68 acres is under acquisition. This notification is made under the provisions of Section 11 (1) of the Mizoram (Land Acquisition, Rehabilitation & Resettlement) Act, 2016, to all whom it may concern. A plan of the land may be inspected in the office of the District Collector and Settlement Officer of concerned District on any working day during working hours. Objections, if any, to the acquisition regarding: iv)The area and suitability of land proposed to be acquired. v)Justification offered for public purpose. vi)The findings of the Social Impact Assessment Report. may be filed by the person interested within 60 (sixty) days from the date of publication of this notification as provided under Section 15 of the Act before the District Collector, Kolasib District. Lalram Thanga, Principal to the Govt. of Mizoram, Land Revenue & Settlement Deptt. Published and Issued by the Controller, Printing & Stationery, Mizoram Printed at the Mizoram Government Press, Aizawl C-50The composition of the Site Allotment Advisory Board and its functions are as given in Annexure I, II, III & IV.
The Mizoram Gazette EXTRA ORDINARY Published by Authority RNI No. 27009/1973 Postal Regn. No. NE-313(MZ) 2006-2008VOL - XLVI Aizawl, Friday 24.3.2017 Chaitra 3, S.E. 1939, Issue No. 122 NOTIFICATIONNo.H.11018/6/2008-REV/Pt, the 24th February, 2017.In exercise of the power conferred under sub- section (1) of Section 16 of the Mizoram (Land Revenue) Act, 2013 (Act No.5 of 2013) the Governor of Mizoram is pleased to constitute Site Allotment Advisory Board (SAAB) in each District, notified towns or sub-towns and in revenue villages as declared by the Government under rule 3(1) of the Mizoram (Land Survey and Settlement Operation) Rules, 2009 to ensure just and fair selection for allotment of any cat- egory of land to the deserving family or families or juristic person where suitable vacant land is available. The composition of the Site Allotment Advisory Board and its functions are as given in Annexure I, II, III& I V. This will supersede all previous Notifications issued with regard to constitution of Site Allotment Advisory Board. Lalram Thanga, Principal Secretary to the Govt. of Mizoram, Land Revenue & Settlement Department. Ex-122/2017 2 ANNEXURE - I COMPOSITION OF SAAB (In the District Headquarters) 1. Chairman- Deputy Commissioner of the District or his representative. 2. Member Secretary- Settlement Officer or Assistant Settlement Officer. 3. Members- 1)President o f Lo cal Co uncil/President Village Co uncil. 2)Representative of National Political parties and Recognised Po lit ical part ies o f t he Dist rict . 3)President Central Y.M.A./Sub Headquarters Y.M.A. 4)President M.U.P. headquarters/sub-headquarters. 5)The concerned Divisional Forest Officer. 6)Representatives of Chief Engineer, PWD, P&E, PHE not below the rank of S.E. ANNEXURE - II COMPOSITION OF SAAB (In the Sub-Division and Block Headquarters) 1. Chairman-S.D.O(Civil)/B.D.O. 2. Member Secretary-Headmaster Higher Secondary School or High School of Sub-Divisional or as Block Headquarters. 3. Members- 1)President Village Co uncil in t he Sub-Divisio n Hqrs. o r RD Block headquarters. 2)Representative of Political parties (Recognised and Na- t io nal). 3)President Joint Y.M.A. of the Sub-Division Hqrs. or RD Block headquarters concerned. 4)President , Mizo ram Upa Paw l ( MUP) o f t he Civil S ub- Division or RD Block Headquarters. 5)Prominent persons not more than 3 no minated by the Co m- mit t ee 6)D.F.O. of the concerned Civil Sub-Divisional or his repre- sentative not below the rank of R.O. 7)E.E, P.W.D, P&E, P.H.E. or their representatives not be- low the rank of SDO/JE of the Civil Sub-Division or RD Block Headquarter concerned. 8)Representative of Settlement Officer of the District con- cerned or Assistant Settlement Officer of the District con- cerned. ANNEXURE - III COMPOSITION OF SAAB (In the notified town and villages where Survey Operation have not yet done) 1. Chairman-President o f Jo int Village Co uncil o r Village Co uncil. 2. Member Secretary-Headmaster High School/Middle School. 3. Members- 1)Secretary, Village Council. 2)Representative of National Political Party and recognized po lit ical part y. 3)Representatives of PWD, PHE and P&E not below t he rank of J.E. 4)Represent ative o f Environment & Forest not below the rank of R.O. 5)President, Mizoram Upa Pawl. 6)Prominent person not more than 2(two). 7)President, Joint Y.M.A/Branch Y.M.A. 8)Representative of Settlement Officer of the District con- cerned or Assistant Settlement Officer of the District con- cerned.Ex-122/2017 3 ANNEXURE - IVFUNCTIONS AND TERMS OF REFERENCE OF THE SAAB.1.The Site Allotment Advisory Board will be the Screening Board in the matter of application for allotment of land for agricultural and non agricultural purposes. 2.The Board shall have to judiciously examine the applicant’s originality with reference to sub-section (16) and (45) of Section 2 of the Mizoram (Land Revenue) Act, 2013. If the condition in these provisions are not fulfilled by the applicant or applicants the Board shall have to reject outright. 3.The Board shall have its sitting at least twice in a year or as may be required and TA shall be given to the members of the Board if the place of its sitting is more than 8 (eight) kilometer from the headquarter of the Member. The Secretary SAAB shall issue Meeting Notice in consultation with the Chairman by giving at least 10(ten) days in advance to the member of SAAB. 4.All applications in prescribed Form for allotment of land in Village Plan area as referred in Explanation to Sub-rule(1) of Rule 14 and Rule 16 of the Mizoram (Land Revenue) Rules, 2013 read with Section 39 and 40 of the Act for any category or purpose must be submitted to the Settlement Officer or Assistant Settlement Officer if Chairman of SAAB is the Deputy Commissioner of the District. In case, Chairman of SAAB is SDO(C) or BDO or President Village Council the application for land allotment of any category must be submitted to the concerned Chairman. 5.The Board shall make initial screening of the application with regard to location of the applied site. After a summary screening, the Board shall place the matter for demarcation of land by Surveyor, Revenue Department in the presence of the applicant, the concerned VC and neighbouring land holder, if any. Measurement of land should be accurate and NOC is as prescribed by Revenue Department. 6.The demarcation report of the Surveyor duly vetted by Assistant Survey Officer shall be scrutinized by the Board carefully. The recommendation of the meeting of Board shall be submitted t o t he concerned District Officer for furt her submission to the Government through the Director, Land Revenue and Settlement, Aizawl Mizoram for decision of the Govern- ment. 7.In case there are more than one applicant for one plot or one area at SAAB will make recommendation such names in order of priority. 8.The SAAB shall have to examine whether allotment of land will interfere or infringe upon public safety and security or general public health or public inconvenience or adverse im- Ex-122/20174 pact on environment or natural beauty of the area or potential obstruction to future infra- structure development work of the Government. It shall also take into account that the allotment of land shall not violate the provisions of the Mizo ram (Prevention of Go vern- ment Land Encroachment) Act, 2001 as amended from time to time. 9.The term of the Board shall be three years. The Government may, however, dissolve at any time or extend as it may deem necessary in the interest of public.Ex-122/2017 5 Published and Issued by the Controller, Printing & Stationery, Mizoram Printed at the Mizoram Government Press, Aizawl C-50
The Mizoram Gazette EXTRA ORDINARY Published by Authority RNI No. 27009/1973 Postal Regn. No. NE-313(MZ) 2006-2008VOL - XLVI Aizawl, Friday 24.3.2017 Chaitra 3, S.E. 1939, Issue No. 122 NOTIFICATIONNo.H.11018/6/2008-REV/Pt, the 24th February, 2017.In exercise of the power conferred under sub- section (1) of Section 16 of the Mizoram (Land Revenue) Act, 2013 (Act No.5 of 2013) the Governor of Mizoram is pleased to constitute Site Allotment Advisory Board (SAAB) in each District, notified towns or sub-towns and in revenue villages as declared by the Government under rule 3(1) of the Mizoram (Land Survey and Settlement Operation) Rules, 2009 to ensure just and fair selection for allotment of any cat- egory of land to the deserving family or families or juristic person where suitable vacant land is available. The composition of the Site Allotment Advisory Board and its functions are as given in Annexure I, II, III& I V. This will supersede all previous Notifications issued with regard to constitution of Site Allotment Advisory Board. Lalram Thanga, Principal Secretary to the Govt. of Mizoram, Land Revenue & Settlement Department. Ex-122/2017 2 ANNEXURE - I COMPOSITION OF SAAB (In the District Headquarters) 1. Chairman- Deputy Commissioner of the District or his representative. 2. Member Secretary- Settlement Officer or Assistant Settlement Officer. 3. Members- 1)President o f Lo cal Co uncil/President Village Co uncil. 2)Representative of National Political parties and Recognised Po lit ical part ies o f t he Dist rict . 3)President Central Y.M.A./Sub Headquarters Y.M.A. 4)President M.U.P. headquarters/sub-headquarters. 5)The concerned Divisional Forest Officer. 6)Representatives of Chief Engineer, PWD, P&E, PHE not below the rank of S.E. ANNEXURE - II COMPOSITION OF SAAB (In the Sub-Division and Block Headquarters) 1. Chairman-S.D.O(Civil)/B.D.O. 2. Member Secretary-Headmaster Higher Secondary School or High School of Sub-Divisional or as Block Headquarters. 3. Members- 1)President Village Co uncil in t he Sub-Divisio n Hqrs. o r RD Block headquarters. 2)Representative of Political parties (Recognised and Na- t io nal). 3)President Joint Y.M.A. of the Sub-Division Hqrs. or RD Block headquarters concerned. 4)President , Mizo ram Upa Paw l ( MUP) o f t he Civil S ub- Division or RD Block Headquarters. 5)Prominent persons not more than 3 no minated by the Co m- mit t ee 6)D.F.O. of the concerned Civil Sub-Divisional or his repre- sentative not below the rank of R.O. 7)E.E, P.W.D, P&E, P.H.E. or their representatives not be- low the rank of SDO/JE of the Civil Sub-Division or RD Block Headquarter concerned. 8)Representative of Settlement Officer of the District con- cerned or Assistant Settlement Officer of the District con- cerned. ANNEXURE - III COMPOSITION OF SAAB (In the notified town and villages where Survey Operation have not yet done) 1. Chairman-President o f Jo int Village Co uncil o r Village Co uncil. 2. Member Secretary-Headmaster High School/Middle School. 3. Members- 1)Secretary, Village Council. 2)Representative of National Political Party and recognized po lit ical part y. 3)Representatives of PWD, PHE and P&E not below t he rank of J.E. 4)Represent ative o f Environment & Forest not below the rank of R.O. 5)President, Mizoram Upa Pawl. 6)Prominent person not more than 2(two). 7)President, Joint Y.M.A/Branch Y.M.A. 8)Representative of Settlement Officer of the District con- cerned or Assistant Settlement Officer of the District con- cerned.Ex-122/2017 3 ANNEXURE - IVFUNCTIONS AND TERMS OF REFERENCE OF THE SAAB.1.The Site Allotment Advisory Board will be the Screening Board in the matter of application for allotment of land for agricultural and non agricultural purposes. 2.The Board shall have to judiciously examine the applicant’s originality with reference to sub-section (16) and (45) of Section 2 of the Mizoram (Land Revenue) Act, 2013. If the condition in these provisions are not fulfilled by the applicant or applicants the Board shall have to reject outright. 3.The Board shall have its sitting at least twice in a year or as may be required and TA shall be given to the members of the Board if the place of its sitting is more than 8 (eight) kilometer from the headquarter of the Member. The Secretary SAAB shall issue Meeting Notice in consultation with the Chairman by giving at least 10(ten) days in advance to the member of SAAB. 4.All applications in prescribed Form for allotment of land in Village Plan area as referred in Explanation to Sub-rule(1) of Rule 14 and Rule 16 of the Mizoram (Land Revenue) Rules, 2013 read with Section 39 and 40 of the Act for any category or purpose must be submitted to the Settlement Officer or Assistant Settlement Officer if Chairman of SAAB is the Deputy Commissioner of the District. In case, Chairman of SAAB is SDO(C) or BDO or President Village Council the application for land allotment of any category must be submitted to the concerned Chairman. 5.The Board shall make initial screening of the application with regard to location of the applied site. After a summary screening, the Board shall place the matter for demarcation of land by Surveyor, Revenue Department in the presence of the applicant, the concerned VC and neighbouring land holder, if any. Measurement of land should be accurate and NOC is as prescribed by Revenue Department. 6.The demarcation report of the Surveyor duly vetted by Assistant Survey Officer shall be scrutinized by the Board carefully. The recommendation of the meeting of Board shall be submitted t o t he concerned District Officer for furt her submission to the Government through the Director, Land Revenue and Settlement, Aizawl Mizoram for decision of the Govern- ment. 7.In case there are more than one applicant for one plot or one area at SAAB will make recommendation such names in order of priority. 8.The SAAB shall have to examine whether allotment of land will interfere or infringe upon public safety and security or general public health or public inconvenience or adverse im- Ex-122/20174 pact on environment or natural beauty of the area or potential obstruction to future infra- structure development work of the Government. It shall also take into account that the allotment of land shall not violate the provisions of the Mizo ram (Prevention of Go vern- ment Land Encroachment) Act, 2001 as amended from time to time. 9.The term of the Board shall be three years. The Government may, however, dissolve at any time or extend as it may deem necessary in the interest of public.Ex-122/2017 5 Published and Issued by the Controller, Printing & Stationery, Mizoram Printed at the Mizoram Government Press, Aizawl C-50State Level Advisory Committee to monitor implementation of the said Rules with the following members
The Mizoram Gazette EXTRA ORDINARY Published by Authority RNI No. 27009/1973 Postal Regn. No. NE-313(MZ) 2006-2008VOL - XLVI Aizawl, Friday 24.3.2017 Chaitra 3, S.E. 1939, Issue No. 123 NOTIFICATIONNo.C.18011/9/2001 - FST, the 15th March, 2017.As per provision of Rule 16 of the Plastic Waste Management Rules, 2016 and in the interest of public service, the Governor of Mizoram is pleased to constitute the Sta te Level Advisory Committee to monitor implementation of the said Rules with the following member s :- 1.Secretary, Urban Development & Poverty Alleviation Department. -Chairman 2.Chief Conservator of Forests (Admn.), Environment, Forests &-Member Climate Change Department. 3.Member Secretary, Mizoram State Pollution Control Board-Member 4.Municipal Commissioner/CEO, Aizawl Municipal Corporation-Member 5.Sr. Sanitation Officer, Urban Development & Poverty Alleviation-Member Department. 6.Commissioner of Taxes, Taxation Department-Member 7.Dir ector, Commerce & Industries Department.-Member 8.President, Mizoram Chamber of Commerce-Member 9.Head of Department, Department of Biochemistry,-Member Mizoram University. 10. Joint Controller, Food & Drugs, Health & Family Welfare-Member Department. 11. Director, Urban Development & Poverty Alleviation Department.-Convener This notification supersedes earlier notification for constitution of State Level Advisory Body under Plastic Waste (Management & Handling) Rules, 2011. Lalram Thanga, Principal Secretary to the Govt. of Mizoram, Environment, Forests & Climate Change Department. Published and Issued by the Controller, Printing & Stationery, Mizoram Printed at the Mizoram Government Press, Aizawl C-50
The Mizoram Gazette EXTRA ORDINARY Published by Authority RNI No. 27009/1973 Postal Regn. No. NE-313(MZ) 2006-2008VOL - XLVI Aizawl, Friday 24.3.2017 Chaitra 3, S.E. 1939, Issue No. 123 NOTIFICATIONNo.C.18011/9/2001 - FST, the 15th March, 2017.As per provision of Rule 16 of the Plastic Waste Management Rules, 2016 and in the interest of public service, the Governor of Mizoram is pleased to constitute the Sta te Level Advisory Committee to monitor implementation of the said Rules with the following member s :- 1.Secretary, Urban Development & Poverty Alleviation Department. -Chairman 2.Chief Conservator of Forests (Admn.), Environment, Forests &-Member Climate Change Department. 3.Member Secretary, Mizoram State Pollution Control Board-Member 4.Municipal Commissioner/CEO, Aizawl Municipal Corporation-Member 5.Sr. Sanitation Officer, Urban Development & Poverty Alleviation-Member Department. 6.Commissioner of Taxes, Taxation Department-Member 7.Dir ector, Commerce & Industries Department.-Member 8.President, Mizoram Chamber of Commerce-Member 9.Head of Department, Department of Biochemistry,-Member Mizoram University. 10. Joint Controller, Food & Drugs, Health & Family Welfare-Member Department. 11. Director, Urban Development & Poverty Alleviation Department.-Convener This notification supersedes earlier notification for constitution of State Level Advisory Body under Plastic Waste (Management & Handling) Rules, 2011. Lalram Thanga, Principal Secretary to the Govt. of Mizoram, Environment, Forests & Climate Change Department. Published and Issued by the Controller, Printing & Stationery, Mizoram Printed at the Mizoram Government Press, Aizawl C-50The Mizoram State Social Welfare Board with the following members for a period of 3 (three) years or until further orders with immediate effect.
The Mizoram Gazette EXTRA ORDINARY Published by Authority RNI No. 27009/1973 Postal Regn. No. NE-313(MZ) 2006-2008VOL - XLVI Aizawl, Friday 24.3.2017 Chaitra 3, S.E. 1939, Issue No. 124 NOTIFICATIONNo.B.12012/1/2009-SWD, the 15th March, 2017.In supersession of this Department’s Notification of even No. dt.11.12.2009 and in pursuance of the Central Social Welfare Board’s letter No.F.1-20/96- Recon-SBA-Mizoram/301 dt.10.01.2016, the Governor of Mizoram is pleased to reconstitute the Mizoram State Social Welfare Board with the following members for a period of 3(three) years or until further orders with immediate effect. The terms of member is co-terminus with term of the Chairperson, Social Welfare Board. Chairperson : 1.Dr. Lalkailiani D/o K.L. Hnuna (already appointed) Ex-Officio members : 1.Pi Vanlalawmpuii Chawngthu, M.L.A., Dawrpui Vengthar, Aizawl. 2.Dir ector, Socia l Welfare Department. 3.Director, Health Services, Mizoram. 4.Director, Industries, Mizoram. 5.Registrar, Mizoram University. 6.Director, School Education, Mizoram. 7.Director, Rural Development, Mizoram. Non-Official members : 1.Pi Boichhingpuii 2.Dr. Lalthanpuii Hnamte 3.Angela Ch. Ralte 4.Pi Liansangluri 5.Pi Ngurmawii Sailo 6.Pi Lalsangpuii Vanchhawng P. Lalchhuanga, Secretary to the Govt. of Mizoram, Socia l Welfare Department. Published and Issued by the Controller, Printing & Stationery, Mizoram Printed at the Mizoram Government Press, Aizawl C-50
The Mizoram Gazette EXTRA ORDINARY Published by Authority RNI No. 27009/1973 Postal Regn. No. NE-313(MZ) 2006-2008VOL - XLVI Aizawl, Friday 24.3.2017 Chaitra 3, S.E. 1939, Issue No. 124 NOTIFICATIONNo.B.12012/1/2009-SWD, the 15th March, 2017.In supersession of this Department’s Notification of even No. dt.11.12.2009 and in pursuance of the Central Social Welfare Board’s letter No.F.1-20/96- Recon-SBA-Mizoram/301 dt.10.01.2016, the Governor of Mizoram is pleased to reconstitute the Mizoram State Social Welfare Board with the following members for a period of 3(three) years or until further orders with immediate effect. The terms of member is co-terminus with term of the Chairperson, Social Welfare Board. Chairperson : 1.Dr. Lalkailiani D/o K.L. Hnuna (already appointed) Ex-Officio members : 1.Pi Vanlalawmpuii Chawngthu, M.L.A., Dawrpui Vengthar, Aizawl. 2.Dir ector, Socia l Welfare Department. 3.Director, Health Services, Mizoram. 4.Director, Industries, Mizoram. 5.Registrar, Mizoram University. 6.Director, School Education, Mizoram. 7.Director, Rural Development, Mizoram. Non-Official members : 1.Pi Boichhingpuii 2.Dr. Lalthanpuii Hnamte 3.Angela Ch. Ralte 4.Pi Liansangluri 5.Pi Ngurmawii Sailo 6.Pi Lalsangpuii Vanchhawng P. Lalchhuanga, Secretary to the Govt. of Mizoram, Socia l Welfare Department. Published and Issued by the Controller, Printing & Stationery, Mizoram Printed at the Mizoram Government Press, Aizawl C-50Obituary of Pu J.F. Lalramnghaka, Sub Divisional Officer, Chawngte Sub Division, Public Health Engineering Department at 00:45 AM on 15.3.2017
The Mizoram Gazette EXTRA ORDINARY Published by Authority RNI No. 27009/1973 Postal Regn. No. NE-313(MZ) 2006-2008VOL - XLVI Aizawl, Friday 24.3.2017 Chaitra 3, S.E. 1939, Issue No. 125 OBITUARYWith profound grief and sorrow, the Gover nment of Mizora m has learnt t he sad a nd untimely demise of Pu J.F. Lalr amngha ka, Sub Divisional Officer, Chawngte Sub Division, Public Health Engineering Department at 00:45 AM on 15.3.2017. Pu J.F Lalr amnghaka was born on 7.5.1965 and entered into Government service as Junior Engineer under Public Healt h Engineering Department on 22.2.1988. He was promoted to Ju nior Grade of MES (AE/SDO) on 25.4.2012. During his entire tenure of 29 years, he had been serving in various capacities as Junior Engineer and Assistant Engineer/SDO under Public Health Engineering Depa rtment. And he was posted as Sub Divisional Officer, Chawngte Sub Division where he served till he drew his last breath. He served the Government of Mizoram with utmost sincerity and devot ion and endea red himself to all his collea gues. He always proved himself to be a conscientious officer. The Government of Mizoram places on record its appreciation of the sincere services rendered by Pu J.F. Lalramnghaka, Sub Divisional Officer, Chawngte Sub Division, Public Health Engineering Depa rtment a nd conveys its heartfelt sympa thy and condolence to his bereaved family. ‘May his soul rest in peace’. V.Lalremthanga, Secr etary to the Govt. of Mizoram, Public Health Engineering Department.Published and Issued by the Controller, Printing & Stationery, Mizoram Printed at the Mizoram Government Press, Aizawl C-50
The Mizoram Gazette EXTRA ORDINARY Published by Authority RNI No. 27009/1973 Postal Regn. No. NE-313(MZ) 2006-2008VOL - XLVI Aizawl, Friday 24.3.2017 Chaitra 3, S.E. 1939, Issue No. 125 OBITUARYWith profound grief and sorrow, the Gover nment of Mizora m has learnt t he sad a nd untimely demise of Pu J.F. Lalr amngha ka, Sub Divisional Officer, Chawngte Sub Division, Public Health Engineering Department at 00:45 AM on 15.3.2017. Pu J.F Lalr amnghaka was born on 7.5.1965 and entered into Government service as Junior Engineer under Public Healt h Engineering Department on 22.2.1988. He was promoted to Ju nior Grade of MES (AE/SDO) on 25.4.2012. During his entire tenure of 29 years, he had been serving in various capacities as Junior Engineer and Assistant Engineer/SDO under Public Health Engineering Depa rtment. And he was posted as Sub Divisional Officer, Chawngte Sub Division where he served till he drew his last breath. He served the Government of Mizoram with utmost sincerity and devot ion and endea red himself to all his collea gues. He always proved himself to be a conscientious officer. The Government of Mizoram places on record its appreciation of the sincere services rendered by Pu J.F. Lalramnghaka, Sub Divisional Officer, Chawngte Sub Division, Public Health Engineering Depa rtment a nd conveys its heartfelt sympa thy and condolence to his bereaved family. ‘May his soul rest in peace’. V.Lalremthanga, Secr etary to the Govt. of Mizoram, Public Health Engineering Department.Published and Issued by the Controller, Printing & Stationery, Mizoram Printed at the Mizoram Government Press, Aizawl C-50Change Name of John Engmuankima, Forest Guard S/o Sawiluaia presently posted at WPO(N), Aizawl is allowed to change his name as John Engmuankima Ralte.
The Mizoram Gazette EXTRA ORDINARY Published by Authority RNI No. 27009/1973 Postal Regn. No. NE-313(MZ) 2006-2008VOL - XLVI Aizawl, Friday 24.3.2017 Chaitra 3, S.E. 1939, Issue No. 126 OFFICE ORDERSubj : Change of Name. No.A.20030/300/86-PCCF/68, the 17th March, 2017.In pursuance of Office Memorandum No.A.47012/1/2016-P&AR(GSW) Dt. 17.1.2017,John Engmuankima, Forest Guard S /o Sawiluaia presently posted at WPO(N), Aizawlis allowed to change his name as John Engmuankima Ralte. Henceforth, he shall be known asJohn Engmuankima Ralte, and his name shall be written as such in his service records, all Offcial documents and correspondence, and necessary entries shall be made in his Service Book/records. Lalram Thanga, Principal Chief Conservator of Forests, Environment, Forests & Climate Change, Mizo ram : Aizawl. Published and Issued by the Controller, Printing & Stationery, Mizoram Printed at the Mizoram Government Press, Aizawl C-50
The Mizoram Gazette EXTRA ORDINARY Published by Authority RNI No. 27009/1973 Postal Regn. No. NE-313(MZ) 2006-2008VOL - XLVI Aizawl, Friday 24.3.2017 Chaitra 3, S.E. 1939, Issue No. 126 OFFICE ORDERSubj : Change of Name. No.A.20030/300/86-PCCF/68, the 17th March, 2017.In pursuance of Office Memorandum No.A.47012/1/2016-P&AR(GSW) Dt. 17.1.2017,John Engmuankima, Forest Guard S /o Sawiluaia presently posted at WPO(N), Aizawlis allowed to change his name as John Engmuankima Ralte. Henceforth, he shall be known asJohn Engmuankima Ralte, and his name shall be written as such in his service records, all Offcial documents and correspondence, and necessary entries shall be made in his Service Book/records. Lalram Thanga, Principal Chief Conservator of Forests, Environment, Forests & Climate Change, Mizo ram : Aizawl. Published and Issued by the Controller, Printing & Stationery, Mizoram Printed at the Mizoram Government Press, Aizawl C-50The Mizoram Home (Police) Department (Group ‘A’ posts) Recruitment Rules, 2016
The Mizoram Gazette EXTRA ORDINARY Published by Authority RNI No. 27009/1973Postal Regn. No. NE-313(MZ) 2006-2008NOTIFICATIONNo.A.l2018/15(7)/2016-P&AR(GSW), the 15th March, 2017.In ex ercis e of t he powers conferr ed by the proviso to Article 309 of t he Constitution of India, the Governor of Mizoram is pleased to make the following r ules regulating the method of recr uitment to the posts ofSuperintendent of P olice (Ministerial) and Additional Superintendent of Police (Ministerial) u nderHome (Police) Depar tment, Government of Mizor am namely :- 1.Shor t title and (1) These Rules may be called the Mizoram Home (Police) Department commencement (Group ‘A’ posts) Recruitment Rules, 2016 (2) These Rules shall come into force from the date of their publication in the Official Gazette. 2. Application These Rules shall apply to the posts specified in Column I of Annexure-I her et o a nnex ed. 3. Number of posts, The number of the said post(s), classification and the Pay Ba nd & classification and Grade Pay/scale of pay attached t hereto shall be as specified in scale of pay/Pay Column 2 to 4 of the aforesaid Annexure-I Band & Grade Pay 4. Method of r ecruitment, The method of recruitment, age limit, qualifications and other ma tters age limit and other relating to the said post shall be as specified in Column 5 to 14 of qualifications Annexure-I. Provided that the upper age limit prescribed for direct recruitment may be relaxed in t he case of candidates belonging to the Scheduled Castes or the Scheduled Tribes and other special categories of persons in accordance with the orders issued by the Central Government or Government of Mizoram from time to t ime. 5. Disqualification No per son – (a ) Who has entered int o or contracted a mar riage with a person having a spouse living; or VOL - XLVI Aizawl, Friday 24.3.2017 Chaitra 3, S.E. 1938, Issue No. 127 - 2 - Ex-127/2017 (b) Who, having a spouse living, ha s entered into or contracted a marriage with any person shall be eligible for appointment to the said post(s); Provided that the Governor may, if satisfied that such marriage is permissible under the personal law applicable to such person and to the other party to the marriage and that there are other valid grounds for doing so, exempt a ny such person from the operation of these Rules. 6.Training and Every Gover nment s ervant recruit ed under these Rules shall undergo such Departmental training or pass such Departmental Examina tion as may be prescribed Ex amination fr om time to time. 7. Power to transfer Notwithstanding anything contained in these Rules, the Governor of Mizora m, in public interest , shall have the right and power to transfer any officers, so recruited under these Rules to any other post or position which is equivalent in ra nk or gr ade. 8. Power to relax Wher e the Governor is of the opinion that it is necessary or exp edient to do so, he may, by order and for reasons to be recorded in writing in consultation with the Mizoram Public S ervice Commission, through the Depa r t ment of P ersonnel & Administr ative R efor ms, rela x any of the provisions of these Rules with respect to any class or category of persons. 9. Reservation and Nothing in these Rules shall affect any reservations, relaxation of age limit other concessions and other concessions required to be provided for the Scheduled Castes or the Scheduled Tribes and other categories of persons in accordance with the order issued by Central Government or Government of Mizoram from time to time in this regard. 10. Repeal & Savings All Rules framed by the Government of Mizoram pertaining to the post of (i) Superintendent of Police (Ministerial) notified vide No. A. 12018/46/ 2004-P&AR(GSW) dated 16.09.2005 and published in the Mizoram Gazette extraordinary issue No. 253 dated 20.09.2005; and (ii) Additional Superintendent of Police (Ministerial) notified vide No. A. 12018/9/80-APT(B) dated 25.01.1990 and published in the Mizoram Gazette extraordinary issue No. 7 dated 25.01.1990 stands hereby repealed with effect from the dat e of commencement of t hese Ru les. Provided that any order made or a nything done or any action taken under the rules so repealed or under any general order ancillary thereto, shall be deemed to have been made, done or taken under the corresponding provisions of these r ules. By order, etc Lalrinsanga, Joint Secretary to the Govt. of Mizoram. - 3 -Ex-127/2017 ANNEXURE - I (See Rule 2, 3 & 4) RECRUITMENT RULES FOR GROUP ‘A’ POSTS IN HOME (POLICE) DEPARTMENTName of PostNo. of PostClassificationPay Band & Grade Pay/ Scale of PayWhether Selection or Non-Selection posts12345 Selection Superintendent of Police (Ministerial)1 (one) post or as sanctioned by the Govt. from time to timeGeneral State Service (Group ‘A’ Gazetted) (Ministerial Uniformed Ca dre)PB-3 : ^ 15,600 - 39,100 + ^ 7,600 GPWhether benefit of added years of service admissible under Rules 30 of the CCS (Pension) Rules, 1972Age limit for direct recruitmentEducational and other qualif ication required for direct recruitmentWhether the age and educational qualification prescribed for direct recruitmen ts will apply in the case of promotionPeriod of probation, if any67 8910 N.AN.A N.A N.A N.ASelection Additional Superintendent of Police (Ministerial)2 (two) posts or as sanctioned by the Govt. from time to timeGeneral State Service (Group ‘A’ Gazetted) (Ministerial Uniformed Ca dre)PB-3 : ^ 15,600 - 39,100 + ^ 6,600 GPN.AN.A N.A N.A N.AMethod of recruitment whether by direct recruitment or by promotion or by deputation/transfer and percentage of the sanctioned posts to be filled by various methods11121314100% promotion failing which by deputationIn case of recruitment by promotion/transfer/deputation, gra de f rom which promotion/ deputation/transfer to be madeIf DPC exists, what is its composition ?Circumstances in which MPSC is to be consulted in making recruitment As per MPSC (Limitation of Functions) Regulations, 1994 as amended from time to time Mizoram Public Service Commission PROMOTION : From Additional Superintendent of Police (M inisterial) with not less than 5 years of regular service in the grade failing which from Additional Superinten dent of Police (Ministerial) with not less than 20 years of regular service calculated from the date of entry into the post of Sub- Inspector of Police (Ministerial). DEPUTATION : From Officers holding analogous posts under Central/Sta te Government. Period of deputation shall ordinarily not exceed 3 years which may be extended up to 5 years in deserving cases. - 4 - Ex-127/2017Method of recruitment whether by direct recruitment or by promotion or by deputation/transfer and percentage of the sanctioned posts to be filled by various methods11121314100% promotion failing which by deputationIn case of recruitment by promotion/ transfer/deputation, grade from which promotion/deputation/ transfer to be madeIf DPC exists, what is its composition ?Circumstances in which MPSC is to be consulted in making recruitment As per MPSC (Limitation of Functions) Regulations, 1994 as amended from time to time Mizoram Public Service Commission PROMOTION : From Deputy Superinten dent of Police (Ministerial) with not less than 5 years of regular service in the grade DEPUTATION : From Officers holding analogous posts under Central/Sta te Government. Period of deputation shall ordinarily not exceed 3 years which may be extended up to 5 years in deserving cases.Published and Issued by Controller, Printing & Stationery Department, Government of Mizoram Printed at the Mizoram Government Press, Aizawl. C/100
The Mizoram Gazette EXTRA ORDINARY Published by Authority RNI No. 27009/1973Postal Regn. No. NE-313(MZ) 2006-2008NOTIFICATIONNo.A.l2018/15(7)/2016-P&AR(GSW), the 15th March, 2017.In ex ercis e of t he powers conferr ed by the proviso to Article 309 of t he Constitution of India, the Governor of Mizoram is pleased to make the following r ules regulating the method of recr uitment to the posts ofSuperintendent of P olice (Ministerial) and Additional Superintendent of Police (Ministerial) u nderHome (Police) Depar tment, Government of Mizor am namely :- 1.Shor t title and (1) These Rules may be called the Mizoram Home (Police) Department commencement (Group ‘A’ posts) Recruitment Rules, 2016 (2) These Rules shall come into force from the date of their publication in the Official Gazette. 2. Application These Rules shall apply to the posts specified in Column I of Annexure-I her et o a nnex ed. 3. Number of posts, The number of the said post(s), classification and the Pay Ba nd & classification and Grade Pay/scale of pay attached t hereto shall be as specified in scale of pay/Pay Column 2 to 4 of the aforesaid Annexure-I Band & Grade Pay 4. Method of r ecruitment, The method of recruitment, age limit, qualifications and other ma tters age limit and other relating to the said post shall be as specified in Column 5 to 14 of qualifications Annexure-I. Provided that the upper age limit prescribed for direct recruitment may be relaxed in t he case of candidates belonging to the Scheduled Castes or the Scheduled Tribes and other special categories of persons in accordance with the orders issued by the Central Government or Government of Mizoram from time to t ime. 5. Disqualification No per son – (a ) Who has entered int o or contracted a mar riage with a person having a spouse living; or VOL - XLVI Aizawl, Friday 24.3.2017 Chaitra 3, S.E. 1938, Issue No. 127 - 2 - Ex-127/2017 (b) Who, having a spouse living, ha s entered into or contracted a marriage with any person shall be eligible for appointment to the said post(s); Provided that the Governor may, if satisfied that such marriage is permissible under the personal law applicable to such person and to the other party to the marriage and that there are other valid grounds for doing so, exempt a ny such person from the operation of these Rules. 6.Training and Every Gover nment s ervant recruit ed under these Rules shall undergo such Departmental training or pass such Departmental Examina tion as may be prescribed Ex amination fr om time to time. 7. Power to transfer Notwithstanding anything contained in these Rules, the Governor of Mizora m, in public interest , shall have the right and power to transfer any officers, so recruited under these Rules to any other post or position which is equivalent in ra nk or gr ade. 8. Power to relax Wher e the Governor is of the opinion that it is necessary or exp edient to do so, he may, by order and for reasons to be recorded in writing in consultation with the Mizoram Public S ervice Commission, through the Depa r t ment of P ersonnel & Administr ative R efor ms, rela x any of the provisions of these Rules with respect to any class or category of persons. 9. Reservation and Nothing in these Rules shall affect any reservations, relaxation of age limit other concessions and other concessions required to be provided for the Scheduled Castes or the Scheduled Tribes and other categories of persons in accordance with the order issued by Central Government or Government of Mizoram from time to time in this regard. 10. Repeal & Savings All Rules framed by the Government of Mizoram pertaining to the post of (i) Superintendent of Police (Ministerial) notified vide No. A. 12018/46/ 2004-P&AR(GSW) dated 16.09.2005 and published in the Mizoram Gazette extraordinary issue No. 253 dated 20.09.2005; and (ii) Additional Superintendent of Police (Ministerial) notified vide No. A. 12018/9/80-APT(B) dated 25.01.1990 and published in the Mizoram Gazette extraordinary issue No. 7 dated 25.01.1990 stands hereby repealed with effect from the dat e of commencement of t hese Ru les. Provided that any order made or a nything done or any action taken under the rules so repealed or under any general order ancillary thereto, shall be deemed to have been made, done or taken under the corresponding provisions of these r ules. By order, etc Lalrinsanga, Joint Secretary to the Govt. of Mizoram. - 3 -Ex-127/2017 ANNEXURE - I (See Rule 2, 3 & 4) RECRUITMENT RULES FOR GROUP ‘A’ POSTS IN HOME (POLICE) DEPARTMENTName of PostNo. of PostClassificationPay Band & Grade Pay/ Scale of PayWhether Selection or Non-Selection posts12345 Selection Superintendent of Police (Ministerial)1 (one) post or as sanctioned by the Govt. from time to timeGeneral State Service (Group ‘A’ Gazetted) (Ministerial Uniformed Ca dre)PB-3 : ^ 15,600 - 39,100 + ^ 7,600 GPWhether benefit of added years of service admissible under Rules 30 of the CCS (Pension) Rules, 1972Age limit for direct recruitmentEducational and other qualif ication required for direct recruitmentWhether the age and educational qualification prescribed for direct recruitmen ts will apply in the case of promotionPeriod of probation, if any67 8910 N.AN.A N.A N.A N.ASelection Additional Superintendent of Police (Ministerial)2 (two) posts or as sanctioned by the Govt. from time to timeGeneral State Service (Group ‘A’ Gazetted) (Ministerial Uniformed Ca dre)PB-3 : ^ 15,600 - 39,100 + ^ 6,600 GPN.AN.A N.A N.A N.AMethod of recruitment whether by direct recruitment or by promotion or by deputation/transfer and percentage of the sanctioned posts to be filled by various methods11121314100% promotion failing which by deputationIn case of recruitment by promotion/transfer/deputation, gra de f rom which promotion/ deputation/transfer to be madeIf DPC exists, what is its composition ?Circumstances in which MPSC is to be consulted in making recruitment As per MPSC (Limitation of Functions) Regulations, 1994 as amended from time to time Mizoram Public Service Commission PROMOTION : From Additional Superintendent of Police (M inisterial) with not less than 5 years of regular service in the grade failing which from Additional Superinten dent of Police (Ministerial) with not less than 20 years of regular service calculated from the date of entry into the post of Sub- Inspector of Police (Ministerial). DEPUTATION : From Officers holding analogous posts under Central/Sta te Government. Period of deputation shall ordinarily not exceed 3 years which may be extended up to 5 years in deserving cases. - 4 - Ex-127/2017Method of recruitment whether by direct recruitment or by promotion or by deputation/transfer and percentage of the sanctioned posts to be filled by various methods11121314100% promotion failing which by deputationIn case of recruitment by promotion/ transfer/deputation, grade from which promotion/deputation/ transfer to be madeIf DPC exists, what is its composition ?Circumstances in which MPSC is to be consulted in making recruitment As per MPSC (Limitation of Functions) Regulations, 1994 as amended from time to time Mizoram Public Service Commission PROMOTION : From Deputy Superinten dent of Police (Ministerial) with not less than 5 years of regular service in the grade DEPUTATION : From Officers holding analogous posts under Central/Sta te Government. Period of deputation shall ordinarily not exceed 3 years which may be extended up to 5 years in deserving cases.Published and Issued by Controller, Printing & Stationery Department, Government of Mizoram Printed at the Mizoram Government Press, Aizawl. C/100The Aizawl Municipal Corporation hereby renamed Chaltlang North Local Council to Chaltlang Lily Veng Local Council.
The Mizoram Gazette EXTRA ORDINARY Published by Authority RNI No. 27009/1973Postal Regn. No. NE-313(MZ) 2006-2008NOTIFICATIONNo. M. 33029/1/2012-AMC, the 17th March, 2017. In exercise of the powers conferred by Section 2 3(3) of the Mizor am Municipalities Act, 2007 and in pursuance of the resolution of the Board of Councillors, Aizawl Municipal Corporation (AMC) in its meeting dt. 8.3.2017, the Aizawl Municipal Corporation hereby renamed Chaltlang North Loca l Council to Chaltlang Lily Veng Loca l Council. Henceforth, a ll official communications should be addressed to Cha lt lang Lily Veng with immediate effect from the date of issue of this Notification. DR. H. Lalthlangliana, Municipal Commissioner, Aizawl Municipal Corporation. VOL - XLVI Aizawl, Friday 24.3.2017 Chairtra 3, S.E. 1939, Issue No. 128Published and Issued by Controller, Printing & Stationery Department, Government of Mizoram Printed at the Mizoram Government Press, Aizawl. C/50
The Mizoram Gazette EXTRA ORDINARY Published by Authority RNI No. 27009/1973Postal Regn. No. NE-313(MZ) 2006-2008NOTIFICATIONNo. M. 33029/1/2012-AMC, the 17th March, 2017. In exercise of the powers conferred by Section 2 3(3) of the Mizor am Municipalities Act, 2007 and in pursuance of the resolution of the Board of Councillors, Aizawl Municipal Corporation (AMC) in its meeting dt. 8.3.2017, the Aizawl Municipal Corporation hereby renamed Chaltlang North Loca l Council to Chaltlang Lily Veng Loca l Council. Henceforth, a ll official communications should be addressed to Cha lt lang Lily Veng with immediate effect from the date of issue of this Notification. DR. H. Lalthlangliana, Municipal Commissioner, Aizawl Municipal Corporation. VOL - XLVI Aizawl, Friday 24.3.2017 Chairtra 3, S.E. 1939, Issue No. 128Published and Issued by Controller, Printing & Stationery Department, Government of Mizoram Printed at the Mizoram Government Press, Aizawl. C/50Changing Name of Zohmingthanga, Peon Mizoram Legislative Assembly Secretariat
The Mizoram Gazette EXTRA ORDINARY Published by Authority RNI No. 27009/1973Postal Regn. No. NE-313(MZ) 2006-2008OFFICE ORDERNo. LA/ESTT. 15/96/106, the 21st March, 2017. On the written request of Zohmingthanga, Peon Mizoram Legislative Assembly Secreta riat, his name which is recorded as Zohmingthanga in his Service Books etc. is changed to C. Zohmingthanga with immediate effect. Ngurtha nzuala, Secretary. VOL - XLVI Aizawl, Friday 24.3.2017 Chairtra 3, S.E. 1939, Issue No. 129Published and Issued by Controller, Printing & Stationery Department, Government of Mizoram Printed at the Mizoram Government Press, Aizawl. C/50
The Mizoram Gazette EXTRA ORDINARY Published by Authority RNI No. 27009/1973Postal Regn. No. NE-313(MZ) 2006-2008OFFICE ORDERNo. LA/ESTT. 15/96/106, the 21st March, 2017. On the written request of Zohmingthanga, Peon Mizoram Legislative Assembly Secreta riat, his name which is recorded as Zohmingthanga in his Service Books etc. is changed to C. Zohmingthanga with immediate effect. Ngurtha nzuala, Secretary. VOL - XLVI Aizawl, Friday 24.3.2017 Chairtra 3, S.E. 1939, Issue No. 129Published and Issued by Controller, Printing & Stationery Department, Government of Mizoram Printed at the Mizoram Government Press, Aizawl. C/50Changing Name of Pu Mohan Thapa, Hindi Teacher at Aided Middle School, Keitum
The Mizoram Gazette EXTRA ORDINARY Published by Authority RNI No. 27009/1973Postal Regn. No. NE-313(MZ) 2006-2008NOTIFICATIONNo. B. 13011/1/2012-EDN/59, the 22nd March, 2017. The name of Pu Mohan Thapa, Hindi Teacher a t Aided Middle School, Keitum u nder S chool Educa tion Depar tment is hereby cha nged to Pu Vanlalhruaia. Henceforth, his name shall be written as such in all his service records and all other official documents. Khianglianmawii, Under Secretary to the Govt. of Mizoram, School Education Department. VOL - XLVI Aizawl, Friday 24.3.2017 Chairtra 3, S.E. 1939, Issue No. 130Published and Issued by Controller, Printing & Stationery Department, Government of Mizoram Printed at the Mizoram Government Press, Aizawl. C/50
The Mizoram Gazette EXTRA ORDINARY Published by Authority RNI No. 27009/1973Postal Regn. No. NE-313(MZ) 2006-2008NOTIFICATIONNo. B. 13011/1/2012-EDN/59, the 22nd March, 2017. The name of Pu Mohan Thapa, Hindi Teacher a t Aided Middle School, Keitum u nder S chool Educa tion Depar tment is hereby cha nged to Pu Vanlalhruaia. Henceforth, his name shall be written as such in all his service records and all other official documents. Khianglianmawii, Under Secretary to the Govt. of Mizoram, School Education Department. VOL - XLVI Aizawl, Friday 24.3.2017 Chairtra 3, S.E. 1939, Issue No. 130Published and Issued by Controller, Printing & Stationery Department, Government of Mizoram Printed at the Mizoram Government Press, Aizawl. C/50Affidavit of Shri K. Lalhmingsanga alias Lalhmingsanga Khithie S/o K. Tohao, service by occupation and a permanent resident of Laki Village, P.O - Tipa, Siaha District, Mizoram
The Mizoram Gazette EXTRA ORDINARY Published by Authority RNI No. 27009/1973Postal Regn. No. NE-313(MZ) 2006-2008AFFIDAVIT FOR ONE AND SAME PERSONI, Shri K. Lalhmingsanga alias Lalhmingsanga Khithie S/o K. Tohao, service by occupation and a permanent resident of Laki Village, P.O - Tipa, Siaha District, Mizoram do hereby solemnly affirm and declare as follows :- *That I am a bonafide citizen of India by birth belongs to the Scheduled Tribe of Lakher/Mara community as enshrined under Constitution of India. *That I had presented myself as Lalhmingsanga Khithie S/o K. Tohao in all my educational documents and certificates up to my graduation from NEHU. *That I had also presented myself as K. Lalhmingsanga S/o K. Tohao in all my other official documents like birth certificate, Appointment Order etc and in all my training certificates from various institutions. *That though I had presented myself as K. Lalhmingsanga in my official documents as stated above in para 3, the initial in my name ‘K’ stand for Khithie, which I had written in all my educational documents and certificates. *That this affidavit is solely for the purpose of declaring that I am one and the same person having two names as stated above and these two names does not signify two different persons. *That now I solemnly swear this affidavit before the Chief Judicial Magistrate at Siaha that the contents of the above paras are true and correct to the best of my knowledge and belief. In witness whereof I here put my hand and signature on this the 21st day of March, 2017 in the presence of the Magistrate a t Sia ha Court premises. Sd/- DEPONENT Identified by meSworn befor me Sd/-Sd/- Noel L. KompaChief Judicial Magistrate AdvocateSaiha District, Saiha VOL - XLVI Aizawl, Monday 27.3.2017 Chaitra 6, S.E. 1939, Issue No. 131Published and Issued by Controller, Printing & Stationery Department, Government of Mizoram Printed at the Mizoram Government Press, Aizawl. C/50
The Mizoram Gazette EXTRA ORDINARY Published by Authority RNI No. 27009/1973Postal Regn. No. NE-313(MZ) 2006-2008AFFIDAVIT FOR ONE AND SAME PERSONI, Shri K. Lalhmingsanga alias Lalhmingsanga Khithie S/o K. Tohao, service by occupation and a permanent resident of Laki Village, P.O - Tipa, Siaha District, Mizoram do hereby solemnly affirm and declare as follows :- *That I am a bonafide citizen of India by birth belongs to the Scheduled Tribe of Lakher/Mara community as enshrined under Constitution of India. *That I had presented myself as Lalhmingsanga Khithie S/o K. Tohao in all my educational documents and certificates up to my graduation from NEHU. *That I had also presented myself as K. Lalhmingsanga S/o K. Tohao in all my other official documents like birth certificate, Appointment Order etc and in all my training certificates from various institutions. *That though I had presented myself as K. Lalhmingsanga in my official documents as stated above in para 3, the initial in my name ‘K’ stand for Khithie, which I had written in all my educational documents and certificates. *That this affidavit is solely for the purpose of declaring that I am one and the same person having two names as stated above and these two names does not signify two different persons. *That now I solemnly swear this affidavit before the Chief Judicial Magistrate at Siaha that the contents of the above paras are true and correct to the best of my knowledge and belief. In witness whereof I here put my hand and signature on this the 21st day of March, 2017 in the presence of the Magistrate a t Sia ha Court premises. Sd/- DEPONENT Identified by meSworn befor me Sd/-Sd/- Noel L. KompaChief Judicial Magistrate AdvocateSaiha District, Saiha VOL - XLVI Aizawl, Monday 27.3.2017 Chaitra 6, S.E. 1939, Issue No. 131Published and Issued by Controller, Printing & Stationery Department, Government of Mizoram Printed at the Mizoram Government Press, Aizawl. C/50The Governor of Mizoram is pleased to notify Mizoram Electrical Licensing Regulations 2017 with immediate effect.
The Mizoram Gazette EXTRA ORDINARY Published by Authority RNI No. 27009/1973 Postal Regn. No. NE-313(MZ) 2006-2008VOL - XLVI Aizawl, Wednesday 8.3.2017 Phalguna 17, S.E. 1938, Issue No. 62 NOTIFICATIONNo.B.16013/24/2013-P&E, the 28th February, 2017.In compliance with the decision taken by Coun- cil of Ministers in its meeting held on 8th Feb. 2017 the Governor of Mizoram is pleased to notify Mizoram Electrical Licensing Regulations 2017 with immediate effect. This issues with the concurrence of Finance Department vide their I.D. No.FIN(E) 596/2016 dt.12.12.2016 and Law & Judicial Department vide their I.D No.LJD-33/2016/96 dt.13.7.2016. C. Lalhmachhuana, Secretary to the Govt. of Mizoram, Power & Electricity Department. Ex-62/20172 NOTIFICATION No B.16013/24/2013-P&E the 28th Feb. 2017. The Governor of Mizoram is pleased to order that grant of Licences to Electrical Contractors, Certificates of competency to Electrical Supervisors and Permits to Electrical Wor kmen shall be governed by the Mizoram Electr ical Licensing Regulation 2017 framed in accordance with Regulation 29 of Central Electricity Authority (Measures relating to Safety and Electric Supply) R egulations, 2010 namely - The Mizoram Electrical Licensing Regulations, 2017 1.Short title, extent and commencement: 1)These Regulations shall be called the Mizoram Electrical Licensing Regulations, 2017. 2)They shall extend to the whole of Mizoram. 3)They shall come into force from the date of publication in the official Gazette. 4)The words used in these Regulations shall have the same meaning as defined and assigned to them in the Electricity Act, 2003 and Central Electricity Authority (Measures relating to Safety and Electric Supply) Regulations, 2010. 2.Abbreviation and Definitions: 1)Chairman means Chair man of Mizoram Electrical Licensing Board. 2)Vice Chairman means Vice Chairma n of Mizoram Electrica l Licensing Board. 3)Secr etary means Secretary to the Mizoram Electrical Licensing Board. 4)Assistant Secretary means Assistant Secretary to the Mizoram Electrical Licensing Board. 5)Boar d means Mizoram Electrical Licensing Board. 6)MELB means M izoram Electrical Licensing Board. 7)Examination means examination conducted by Mizora m Electr ical Licensing Board for Supervisors Certificate and Workma n’s Permit. 8)MELR means Mizoram Electrical Licensing R egulations. 9)JERC means Joint Electricity Regulatory Commission for Manipur & Mizoram. 3.Constitution of Licensing Board: For carrying out the purposes of these Regulations, a Licensing Board namely “ the Mizoram Electrical Licensing Board” hereinafter r eferred to as “ the Boar d” shall be constituted by the State Government of Mizoram. 4.Members of the Licensing Board: The Board shall consist of the following members:- 1)The Secreta ry to t he Government of Mizor am, P&E Department-Chairman (Ex-officio) 2)The Joint Secretary (Technical) to the Government of Mizoram,-ViceChairman P&E Depart ment(Ex-officio) 3)The Chief Electrica l Inspector, Government of Mizoram-Secretary (Ex- officio) 4)The Electrical Inspector, Government of Mizoram- Asst. Secretary (Ex –officio) 5)Principal, Industrial Training Institute, Aizawl-Member 6)Repr esentative of Public Works Department, Mizoram to be nominated by the Department- Member 7)Repr esentat ive of Power & Elect ricity Department, Mizoram to be nominated by the Department- Member 8)Repr esentative of Pu blic Hea lth Engineering Department,- Member Mizoram to be nominated by the Department 9)General Manager, Dir ectorate of Indust ries-Member The State Government may add or r educe number of the members of the Board, other than the Ex-officio members. The Board shall have powers to act not withstanding any vacancy in its membership. 5.Place of office: The office of the Board s hall be situa ted in the sta te capital. 6.Functions of the Board: The functions of t he Boar d shall be - 1)to grant Licences to Elect rical C ontract ors; 2)to conduct examination for Electr ical Supervisors and Electrical Workman; 3)to grant Certifica tes to Electrical Supervisor and Permit to Electrical Workman; 4)to enquire into allegations of incompetence, negligence, violation of the Central Electricity Authority (Measures relating to Safety and Electric S upply) Regulations, 2010 or malpractice on the part of Workman/Supervisor/Contractor holding Permits/Certificates/Licences gra nted by t he Board or breach of conditions as may be considered necessary; 5)generally t o carry out the provisions of these R egulations; 6)to decide on the ca ses of violation of a ny of the provision of these regulations on any person/ group of people, Electrica l Contra ctors, Workman and Supervisor s as per Regula tion No 39; 7)to advise the State Government regarding all matter related to issue of licences, cer tificate or permits and any other matter; 8)to make Amendment of some or all of Mizora m Electrical Licensing Regulation. 7.Meeting of the Board and Quorum: 1)The Board s hall meet once in a year and at such times when the Secr etary feels necessary for transaction of business. 2)The Chairman or Vice Chair man and Secreta ry, together with three other members shall form a quorum at any meeting of the Board. 3)In t he absence of the Cha irman the Vice Chairma n will preside over the meeting. 8.Duties of the Chairman: The duties of the Chairma n shall be:- 1)to preside over meetings of the Board; 2)to take necessary actions to implement decisions of the Board; 3)to keep liaison between the Board and the Government. 9.Duties of t he Vice Chairman: to preside over the meetings of the Boar d in the absence of the Chairman. 10.Duties of the Secretary: The duties of the Secretar y shall be:- 1)to call a meeting of the Board in consultation with the Chair man; 2)to take necessary actions to implement decisions of the Board; 3)to r eceive applica tions of Contr actor ’s Licence, Supervisor ’s Certificate, Workman’s Permit and process them including conduct of examinations; 4)to sign and issue Contractor ’s Licence, Supervisor ’s Certificate, a nd Workman’s Permit . In case of new Licence, Certificate and Permit, Secretar y will issue after obtaining Chairman’s approval; 5)to maintain Registers of Contractor ’s Licence, Supervisor ’s Certificate and Workman’s Permit;Ex-62/2017 3 6)to make all correspondences on behalf of the Board regarding issues/r enewal/ allega tion etc, in r esp ect of Licences , Certif icates and Permits; 7)to place before the Boa rd/Chairman any matter regarding violation of C entral Electricity Authority (Measures relating to Sa fety and Electr ic Supply) Regulations, 2010 or condition of Licences/Certificates/P ermits by Contr actors/ Supervisors/Wor kmen or execution of works by person/contra ctor without valid licence issued by Mizoram Electrical Licensing Board, and can take appropriate action in accordance with the decision of t he Boar d to the viola tors of Mizoram Electrical Licensing Regulations. 11.Duties of the Assistant Secretary: The duties of the Assistant Secretary shall be:- 1)to assist the Secr etary in discha rge of his duties; 2)to act as Secretary in the absence of the Secretary. 12. Electrical Contractor’s Licence: 1)No electrical insta llation work shall be underta ken except by an Electrical Contract or licensed under these regulations read with Regulation 29 of Centr al Electricity Authority (Measures relating to Safety and Electric Supply) Regulations, 2010. 2)An Electrical Contr actor ’s Licence shall be granted only to a person/firmappr oved by the Board who:- a) himself holds an Electrica l Supervisor ’s Certificate or who ha s in his employ at least one S upervisor for Class – I and one Supervisor for class - II holding a valid Certificate granted by the Board a nd who is not a full time employee of a Government or a ny other agency; b)has in his employ at least two Electrical Workmen for class - I and one Electrical Workman for Class - II holding a valid Permit granted by the Board and who is not a full time employee of a Government or any other agency; c)is a permanent resident of Mizora m and not below 18 years of age; d)has in his possession the instruments prescribed for the class of contra ctor which he proposes to apply; e)has the following documents: The Electr icity Act 2003. The C entral Electricity Authority (Installation and Operation of Meters) Regulations, 2006. The Central Electricit y Authority (Measures relating to Sa fety and Electric Supply) Regulations, 2010. The Int imation of Accidents (Form and Time of Service of Notice) Rules, 2005. Mizoram Electrical Licensing Regulations, 2017. The relevant Joint Electricity Regulator y Commission for Manipur & Mizor am Regulations viz:- Electricity Supply Code and any other Notifications regarding regulations of electric supply issued by JERC for Mizoram and Manipur from time to time. f)Fulfill the condit ion laid down in the a pplication for m and pays the prescr ibed initial fee just after the application is approved by the Board. g)any other r equirement that the Board may prescr ibe from time to time such as proof of address of the Contractor ’s establishment, Financial capability, etc. Provided that the Board ma y refuse to gr ant such licence to any person (or firm/ body) who (or which) in the opinion of the Board, is not fit to hold such licence. The Electr ical Contractor ’s Licence is not tra nsfera ble. Ex-62/20174 13. Classes of Electrical Contractors: 1)There shall be three classes of Licensed Electrical Contractors namely Class - I, Class - II and Special Class (Tempora ry). 2)Class –I Electrical Contractor shall be eligible to undertake and carry out all types of Electrical works irrespective of voltage limit, subject to the limit of the Supervisor Certificate held by him or the Supervisor employed by him. The Scope of the wor k may be increased when the limit of the Certificate is increased by paying t he pres cribed fees. A Class - I Contractor ’s Licence may be granted to a person/firm/body who himself holds a valid Certificate of Competency issued under the regulations and a ctually works as a full time Supervisor in r espect of the works undertaken by him and at least two Workmen, each holding a valid permit issued under these Regulations, under his full time employment or to a person or a firm having at least one Supervisors, holding a valid Certificate of Competency issued under these Regulations and at least two Workmen, holding a valid permit issued under these Regulations under his or its fulltime employment provided such person or firm has in his/its possession a ll the instruments and tools of the B.I.S. standard in adequate number for carrying out the test and exa minations . 3)The Contractor should possess at least the following instruments: 1) Insulation Tester: 500V, 1000V, and 2500V- 1 No ea ch. 2) Earth Tester with accessories (0-10) Ohms- 1 No 3) Voltmeter 0-600V- 1 No 4) Tong Tester with Ammeter 300V- 1 No 5) Phase Sequence Indicator- 1 No 6) Crimpling tool with Dye set- 1 No 7) Suitable Rubber hand Gloves- 1 pair for each wor kman 8) Porta ble drilling machine- 1 No In addit ion to the above, the Contract or should have in his/its possession all the instruments and tools of B.I.S Standard in adequa te number for car rying out the execution, tests a nd inspections of all classes of wor ks authorized as specified by the Board. 4)Class-II Electrical Contractor shall be eligible to carr y out electrical wiring and installa tion works up to 650 Volts, subject to the class limits of the Certificate of the Electrical Supervisor employed. The scope of the works may be increased when the limit of the Certificate is increased by paying t he prescribed fees. A Class-II Contractor ’s L icense may be granted to a person who himself holds a valid certificate of Competency issued under these r egulations and actually works as a full time Supervisor in respect of the works underta ken by him and has at least one Workman, holding a valid Permit issued under these regulations, under his or its full time employment or to a person or a firm having a t least one Supervisor holding valid Certificate of Competency issued under these regulations and at least one workman each holding a valid P ermit issued under these regulations, under his or its full time employment provided such person or firm has in his or its possess ion all the instruments and tools of the B.I.S standard in adequate number for carrying out the test s and examination as required under the Rules. 5)The contractor should possess at least the following Instruments: 1)Insulation Tester: 500V- 1 No 2)Earth Tester with accessories (0-10) Ohms- 1 No 3)Voltmeter 0-600V- 1 NoEx-62/2017 5 4)Tong Tester with Ammeter, 300V- 1 No 5)Porta ble drilling machine- 1 No 6)Phase Sequence indicator- 1 No In a ddition to the above, the Contractor should have in his/its possession a ll the instruments and tools of BIS Standard in adequate number for carrying out the execution, tests and inspections of all classes of wor ks authorised as specified by the Board. 6)Special Class (Temporary): In addition to the above two general classes, there may be a Special Class (Temporary) Contractor ’s Licence which is non-renewable a nd shall be issued for a period of six months only under very special circumstances. Depending upon the limit of Supervisors and Workmen employed by the Contr actor a nd the availability and Capacity of the testing instruments in his possess ion, this class of Contractor shall be eligible to undertake all t ypes of works ca pable of being carried out by either Class-I or Cla ss-II C ontract ors. Provided that the Board may also grant Non-Renewable Certificate of competency for six months at a time to a Supervisor engaged by such firm or person on t he strength of the Certificate of competency issued by competent authority of any other St ate. 14.When Electrical Contractor’s License shall not be granted: An Electrical Contractor ’s Licence shall not be granted to a ny holder of a n Electrical Supervisor ’s Certificate or any holder of an Electrical Workman’s Permit while he is the employee of another Electrical Contractor. 15.Application for Electrical Contractor’s licence: Application for Electrica l Contr actor ’s licence shall be made to the Secretary in Form - A by pa ying the schedule of fees in Annexure -1. 16.Forms of Electrical Contractor’s Licence: An Electrica l Contra ctor ’s Licence shall be issued in Form - D 17.Cancellation of Electrical Contractor’s Licence. 1)If the Electrica l Supervisor /Workman, on the strength of whoman Electrical Contract or ’s Licence has been granted, leaves the service of such E lectrical Contractor, such C ontract or ’s Licence sha ll be deemed to have been su spended. If such Elect rical Contract or fails to employ an Electrical Supervisor/Electrical Workman within one month from the date on which the Electrical S upervisor and Electrical Workman had left such Electrical Contractor ’s service, such Electr ical Contractor ’s Licence shall be cancelled. 2)If a n Electrical Supervisor/Workma n to whom an Electr ical Contractor ’s licence has been granted accepts employment under a ny other Electr ical Contractor, the Contract or ’s Licence granted to such Electrica l Supervisor/Workman shall be automa tically cancelled. 3)The Board may, at any time cancel an Electrica l Contr actor ’s Licence if the person (or firm) to whom the Licence has been granted is in the opinion of the Board, not fit to hold the Licence. F or this purpose the Board may take into consideration, a mongst others, the provisions cont ained in Regulation 38. 18. Renewal of Electrical Contractor ’s Licence: 1)Every Electrica l Contr actor ’s Licence granted under these Regula tions shall be renewed annually. A licence which is not r enewed after expiry will become invalid from the date of expiry. Application for renewal in Form - J together with the Licence and Non-Refundable prescribed fees shall be submitted to the Secretary at least one month before the date of expiry of the Licence. Ex-62/20176 Provided that if t he application for renewal as aforesaid is r eceived within one month from the date of expiry of the Licence, it may be renewed on payment of the prescr ibed annu al renewal fee and prescribed fee for la te renewa l of the Licenc e. The date of next ex pir y will be twelve months from the date of last expiry. 2)Electrical Contract or ’s Licence, which is not renewed within one month from the date of expiry, will be automatica lly cancelled. Fresh initial fee with an application in Form - A must be furnished as in case of fresh application befor e a new Licence is granted. 3)The Licence shall automatically b ecome invalid after its expiry till renewal and no electr ical work shall be done by the Contractor while the Licence is inva lid. 19. Forms to be maintained: All Licensed Electr ical Contractor s are required to maintain the following Forms and s ubmit to the Secretary, Mizoram Electrical Licensing Board along with applications for renewal of their respective Licences. (a) Form - H details of Supervisor, Workman and Apprentices. (b) Form - I Yearly return of work done. 20. Register of Contractors: A register of all Electrical Contractor s Licence under these Regula tions shall be mainta ined by the Secr etary, Mizoram Electr ical Licensing Board and published from time to time. 21.Electrical Contractor to keep instruments in good condition: 1)All Electrical Contractors, to whom Licences have been granted, shall keep all the prescribed instruments in good condition. 2)The instruments in the possession of every Licensed Electrical Contra ctor ma y be inspected fr om time to time by the Secretary or his repr esentatives. 22. Notice of termination of service: If a n Electrical Supervisor/Workman in the employment of a Licensed Electrica l Contra ctor leaves his service, the termination of the service sha ll be notified in writing to the Secretary, both by the Electrical C ontract or and t he Electrical S upervisor/ Workman. 23. Work Execution: a)All electrical ins tallation works are to be car ried out by Electrica l Contr actor having valid licence under the direct supervision of the Electrical Supervisor holding va lid licence and by a Workman holding a valid permit issued by the Board. b)The contractor shall submit notice before commencement of work to the SDO (P&E) concerned, the Electrical Inspectorate in Form – K wherever a new work is taken up by him; provided notice for interna l wiring works upto 20kw load may be given to the SDO (P&E) concerned o nl y. c)No electrical installation work which has been carried out in contra vention of sub-regula tion (a) shall either be energized or connected to the works of any energy supplier. [Regulation 29 (2) Central Electricity Authority (Measures relating to Safety and Electric Supply) Regulation, 2010]. 24. Test Reports: 1)For all electrical installation works car ried out as per Regula tion 29 of The Central Electricity Authority (Measures relating to Safety and Electric Supply) Regulations, 2010, Test reports shall be submitted by the Licensed Electrical Contractor to the Electrical Energy Supplier/Ex-62/2017 7 Supplier of energy concerned in the form approved by Electrical Inspector under Regula tion 31 of The Central Electr icity Authorit y (Measures r elating to Safety and Elect ric Supply) Regulations, 2010. 2)After carrying out all the necess ary test s of all elect rical installation wor ks, the test report shall be filled up and signed by the Electrica l Supervisor under whose supervision the works have been ca rried out. All the test results should be sa tisfact ory and within permissible limits. The Test Report shall be counter signed by the Licensed Electrical Contractor. 3)The Licensed Electrical Contract or and Electrical Supervisor shall be jointly resp onsible for the due execution of all the electrical installation works and the materials used and the Electrical Supervisor shall be present at the time of testing by the Electrical Energy Supplier/Supplier of Energy concerned. 25. Examination: 1)Examination shall be held for Supervisor s and Workman b y the Board at such places and on such dates a s may b e notified by t he Secretary from time to time in loca l Newspa per. 2)Every examination shall be of such nature as to test the practical knowledge of the candidate and to ascertain his competency a nd the adequacy of his practical experience to the satisfaction of the Board for the purpose of gr anting Permits and Certificates under these Regulations. 3)Every examination shall be conducted in a pla ce where the ca ndidate’s knowledge can be practically tested and each candidate sha ll be tested with written and viva-voce. 4)The examina tions a nd test shall be held in English or in the officia l Language depending upon the choice of the candidate. 5)The Board s hall hold examinations normally twice a year on dates to be circulated by the Secr etary of the Board. 6)The fees pa id by a candida te, whose application for admission to an examination has been accepted, s hall not be refunded on any account. If the candidate fails to appear in examination, fees paid will be for feited. 26. Qualification: To appear in the exa mination, a candidate should be as under – 1)In r espect of Elec trical Supervisor ’s C ertific ate: Candidates for exa mination of Electrica l Supervisor ’s Certificate shall be person who- (i)have passed class X. (ii)are permanent residents of Mizor am and not below 18 year of age. (iii)have passed the examination for Electr ical Workman and have at least 5 year s practical experience, of which not less tha n two years should be a fter passing Wor kman’s Permit Examina tion 2)In r espect of Electrical Workma n’s Permit: Candidates for examination of Electrical Workman’s Permit shall be a person who - (i)have passed class VIII (ii)are permanent residents of Mizor am and not below 18 years of age (iii)have worked on wiring and electr ical installation work as an apprentice for at least two years under Licensed Electrical Contractor, or (iv)have passed other electrical training or practica l experience in electr ical installation works, which is regarded, satisfa ctory by the Board. 27. Full Marks: Full Marks would b e as under- Ex-62/20178 1)For Electrical Supervisor ’s Certificate: a. Written - 100 b. Viva Voce- 100 2)For Workman’s Permit: a. Written - 100 b. Viva Voce- 100 28. Pass Marks: Electrical Supervisor ’s Certificate and Electrical Wor kman’s permit will not be granted unless a candidate secures 50% of total marks each in written examination and viva voce. Candidates who are exempt ed from written examination also ha ve to secure a t least 50% marks in viva voce. 1)The Board may grant Electrical Supervisor ’s certificate in any class commensurate with practical knowledge and experience to a candida te who holds a Degree or diploma in Electr ical Engineering, Electrica l & Electronic Engineering, Electronic Engineering, Mechanical Engineering, Electronic a nd Communication Engineering and Electronic and Telecommunication Engineer ing without requiring him to sit for written examina tion, based on viva-voce, after paying the prescribed initial fee. 2)The Board ma y also grant Supervisor ’s Certificate for Cla ss–I – C lass–IV to a Degree Or Diploma candidates of retired Electrica l Engineers, Electrica l and Electronic Engineers, Mechanical Engineering, Electronic Engineers, Electronic and Communication Engineers and Electr onic and Telecommunica tion Engineers of P &E Depar tment, Mizoram aft er passing viva -voce examination and after paying initial fee. 29. Examination for Electrical Supervisor’s Certificate: 1)A ca ndidate for Electrical Supervisor ’s Certificate examination must apply to the S ecretar y in prescribed form (Form-B) with the following docu ments and pay the examination fee: i) Attested copy of Voter ’s ID. ii) Certificate from Contractor in Form ‘G’ - appended to these R egulations. iii) Electrical Workman’s Permit, if any. iv) Certificate of technical qua lifications (attested copy) v) Two copies of recent passport size photographs, all of which shall bear the applicant’s name on the back. 2)Candidate for examination of Electrical Supervisor ’s Certifica te shall be examined by a written paper and by Oral t ests. Candidate will normally be examined thr ough the medium of English language but the Board may permit a candidate to be exa mined through any other medium as may be possible for the Board to arra nge. 3)The syllabus of the several parts of the examinations is set out in Annexur e - II. Candidates may appear in examinations for any class. The class to be passed to qualify for different Classes of Certificates are as below: 4)For the purpose of these Regulations all Electrical installation works shall be divided in cla sses as shown below: ClassesCertificate for Part compulsory Class-IWiring for system not exceeding 650 Volts- 1,2,3,4 Class-IIOverhead lines and installationsnot exceeding 33,000volts- 1,4,5,6,7,9 Class - III Underground Cable not exceeding 33,000volts- 1,7,8 Class-IVOverhead lines and installations exceeding 33,000 volts - 1,4,5,6,7,9,10Ex-62/2017 9 30.Grant of Electrical Supervisor’s Certificate: 1)Every candidate who passed the examinations for Electrical Supervisor will be granted a certificate for the installation works of differ ent cla sses which he passed a s set ou t in Form - E, a fter pa ying the prescr ibed initial fee within one (1) year from the date of declaration of examination result. 2)The Board ma y also grant Electrica l Supervisor ’s certificate in any class commensurate with practical knowledge and experience to a candida te who holds a Degree or diploma in Electr ical Engineering, Electrica l & Electronic Engineering, Electronic Engineering, Mechanical Engineering, Electronic a nd Communication Engineering and Electronic and Telecommunication Engineer ing without requiring him to sit for written examina tion, based on viva-voce, after paying the prescribed initial fee. 3)The Board may also grant S upervisor ’s Certifica te for Class-I – Class–IV to a Degree or Diploma candidates of retired Electrical Engineers, Electrical and Electronic Engineers, Mechanical Engineering, Electronic Engineers, Electronic and Communication Engineers and Electr onic and Telecommunica tion Engineers of P &E Depar tment, Mizoram aft er passing viva – voce examina tion and after paying initial fee. 31. Renewal of Electrical Supervisor’s Certificate: 1)Ever y Electr ical S u pervisor ’s Cert ificate gr anted under these Regula tions sha ll be renewed ever y year or three years a t a time after paying prescribed fees shown in Annexure - I. Any Certificate, which is not r enewed after expiry will become invalid from the date of exp iry. Application for renewal in Form - L together with the Supervisor ’s Certificate and non- refundable prescribed fees shall be submitted to the Secretary within one month before the date of exp iry of the Certificates. Provided tha t if the application for renewal as a foresaid is received within twelve- months from the date of expiry of the Certificate, it may be renewed on p ayment of the prescrib ed r enewal fee and pres cribed fee for la te renewa l of the Certific ate. The date of renewal after expiry will be the date on which the Certificate is renewed. The date of next expiry will be one year or three years or from the date of last expiry. 2)Electrical S upervisor Certificate, which has not been renewed within twelve months from the date of expiry, will be automatically cancelled and fresh initial fee with an applica tion in Form - B must be fu rnished as in case of fresh application before a new Supervisor ’s certificate will be granted. 3)The Board may, at any time cancel an Electrical Supervisor ’s certificate if the per son to whom the Certificate has been gr anted is in the opinion of the Board, not fit to hold such Certificate. For this purpose the Board may take into consideration, amongst other, the Provisions contained in Regulation 31. 32. Examination for Electrical Workman’s Permit: 1)A ca ndidate for exa mination of Electrical Workma n’s Permit must apply to the Secretar y in prescribed form For m - C with the following documents and pay the examination fee: i)Attested copy of Voter ’s ID. ii)Certificate from Contract or in F orm - G appended to these Regulations. iii)Electrical Workman’s Permit, if any. iv)Certificate of technical qua lifications (attested copy) v)Two copies of recent passport size photographs, all of which s hall bear the a pplicant’s name on the back. 2)Candidate for examinations of Electrical Workman’s Permit shall be examined by a written paper and by Oral t ests. Candidate will normally be examined thr ough the medium of English language but the Board may permit a candidate to be exa mined through any other medium as may be possible for the Board to arra nge. Ex-62/201710 3)The syllabus of the severa l parts of the examinations is set out in Annexure - III. Candidates may appear in examinations for any class. The class to be passed to qualify for different Classes of Permit are as below: 4)For the purpose of these Regulations all Electrical installation works shall be divided in cla sses as shown below: ClassesCertificate forPart compulsory Class-I:Wir ing for system not exceeding 650 Volts- 1,2,3,4 Class-II:Overhead lines & installations not exceeding 33,000volts- 1,4,5,6,7,9 Class - III :Underground Cable not exceeding 33,000volts- 1,7,8 Class-IV:Overhead lines & installations exceeding 33,000 volts- 1,4,5,6,7,9,10 33. Grant of Electrical Workman’s Permit: 1)Every candidate who passed the examinations for electrical Workman shall be granted a Permit for the installation works of different classes which he passed as set out in For m - F a fter paying the prescribed initial fee within one (1 ) year from the date of declaration of result. 2)The Board may also grant a Permit to any candidate who ha s passed I.T.I from any recognized institute in the trade of Electrician, Wireman, Mechanic Refrigerator and A/C, Mechanic Radio and Television, Electronic Mechanic, Information Technology and Electr onic System Maintenance whose qualification and pra ctical experience are such a s to justify the grant of Workman permit of the appropriate class after passing Viva-Voce, without written examination, after paying the prescribed initial fee” 34. Renewal of Electrical Workman’s Permit: 1)Every Electr ical Workman’s Permit granted under these Regulations shall be renewed every year or three years at a time after paying prescribed fees shown in Annexure -I. Any Permit, which is not renewed after expiry will, become invalid fr om the date of expiry. Applica tion for renewal in Form - L together with the Workma n’s Permit and non- refundable prescr ibed fees shall be submitted to the Secretary within one month before the da te of expiry of the Permit. Provided tha t if the application for renewal as a foresaid is received within twelve- months from the date of expiry of the Permit , it may be renewed on payment of the prescribed renewal fee and prescribed fee for la te r enewa l of the Permit . The dat e of r enewa l a fter ex pir y will be the date on which the Permit is renewed. T he date of next expiry will be one year or three years from the date of la st exp iry. 2)Electrical Workman‘s Permit, which has not been renewed within twelve months from the date of expiry, will be automatically cancelled and fresh initial fee with an applica tion in Form - C must be fu rnished as in case of fresh a pplication before a new Workman’s Permit will be granted. 3)The Board ma y, at a ny time cancel an Electrical Workman’s Permit if the person to whom the Permit has been gra nted is in the opinion of the Board, not fit to hold such Permit. For this purpose the Board may take into considera tion, a mongst other, the Provisions contained in Regulation 31. 35. Grant of Duplicate Licence, Certificate or Permit: On being sa tisfied that an original Licence, Certificate or Permit gr anted under these regulations has been lost or destroyed, the Secretary may, on request in writing by the application, grant a duplicate. A duplicate of Licence, Certifica te or Permit gr anted under these Regulations shall be issued on payment of the pres cribed fee.Ex-62/2017 11 36. Restriction of employment for Electrical Supervisors and Electrical Workmen: 1)A person holding Electrical Supervisor ’s Certificate should not be an employee of more than two different Elect rical Licensed Contract ors within the same period. 2)A person holding E lectrica l Workman’s Permit should not be an employee of more than one Electrical Licensed Contractor within the same period 3)An Electrical Supervisor/Workman employed by a Licensed Electr ical Contractor should not be a regular/Work charged/officiating/contract/muster roll employee of a Central or State Government or a Government undertaking or a regular/full time employee of any other Compa ny or Firm or Agency. 4)A person holding both Supervisor ’s Certificate a nd Contractor ’s Licence should not be an employee of a ny other Contractor. 37. Report of negligence: 1)When a situation a rises in which a Licensee or a person for whom any elect rical installa tion work is being or has been carried out by an Electrical Contractor licensed under these Regulations, is, in the opinion of the licensee or a person, not in conformity with the Central Electricity Authority (Measures relating to safety and Electric Supply) Regulations, 2010 and Licensee or person desires to bring the facts to the notice of the Board, he shall make a report in writing to the Secretary. 2)A report ma de to t he Secretary under these regulations by a person other tha n a Licensee shall be accompanied by a deposit of Rs. 500.00 or such larger amount as the Board may fix by special order in any case. If in the opinion of the Boa rd, the charge contained in the repor t is not substantiated, the Board may direct that the deposit shall be forfeited, if the report is substantiated, the deposit shall be retur ned. 3)If electrical insta llation work has been being or has been car ried out by Electrical Contra ctor licensed under these regulations is actually not in conformity with the Central Electricity Authority (measures relating to Safety and Electric Supply) Regulation, 2010, the Board may take action as deemed fit, which may enta il imposition of cancellation or suspension of licence. Decision of the Board will be final. 4)If any person holding an Electrical Wor kma n’s Permit or a Supervisor ’s cer tifica te or an Electr ical Contractor ’s L icence is found by the Boar d to be guilty of negligence, misrepresentation or delibera te suppr ession of facts, incompetence or breach of these Regulations or of t he conditions of his P ermit, Certificate or Licence. The Board may take action as deemed fit which may entail suspension or cancella tion of licence. The decision of the Board in these regar ds shall be final. 5)If a ny mutilation or defacement of, or any unauthorized entry in any E lectrica l Workman’s Permit or Electrical Supervisor ’s Certificate or Electrical Contract or ’s Licence is found the Boar d may take act ion as deemed fit which may entail cancellation. The Board’s decision will be final. 38. Electrical Licensee to obtain Contractor ’s Licence: No electrica l installation work shall be ca rried out by a person licensed under P art - IV of the Electricity Act 2003 or an Electricity Board or a State Government Depa rtment responsible for the distribution of energy, in a premises beyond the point of commencement of supply unless he has obta ined an Electrical Contractor ’s Licence and employs staff of Electrical Supervisors and Electr ical Workman in conformity with these R egulations. 39. Cancellation of Contractor’s Licence granted to Electrical Licensee: An Electrical Contr actor ’s Licence granted under Part - IV of the Electricity Act, 2003 shall be liable to be withdr awn or cancelled if in the opinion of the Board pr eferential treatment r esulting in unfa ir competition with local contractors is given to prospective consumers. Ex-62/201712 40. Amendment of Annexure: Schedule of fees contained in Annexure-I, Syllabus for Electrical Supervisor ’s Certificate Examinations contain in Annexure-II, Syllabus for Electrical Workman’s Permit Examinations contain in Annexure-III and Forms contained in Annexure-IV and remuneration for examiners etc may be amended by the Board from time to time. 41. General Provisions for Appeals: 1)An appeal against a n order made under these regulations shall lie to the State Government. 2)Every appeal made under sub-regulation (1) shall be in writing accompanied by a cop y of the order appealed against and shall be presented within 3 months of the date on which such order ha d been made. 42. Remuneration for Examiners and invigilators: An Examiner shall r eceive the remuneration as pr escribed by the Sta te Government from time to time. 43. Mode of Contract:- 1)Every Elect rical installation work under taken by a Contractor shall be recor ded in writing and the Contractor shall be held responsible for the workma nship and qualit y of all materia ls supplied by him and used in the wor k for the proper execution of the Contractor. All the installation work shall be recor ded as per Form - I as prescr ibed in the schedule of Form and shall be opened for Inspection. 2)No Electrical installation works including additions, alteration repair and adjustments to existing installation, excepting such replacement of lamps, fans, fuses, switches and other components/ parts of the installations which, in no way alteration of its capacity or character, shall be commenced by a Contractor without notifying the Secretary and the Electrica l Inspector ha ving jurisdiction and the concerned Electrical supply authorit y in Form - K a s prescribed in the form. Provided that notice for int ernal wiring works upto 20kW load may be given to the SDO (P&E) concerned only. Before the commencement of the actual work, the Contractor shall obtain the approved copies of the electrical drawings (approved by the concerned Electric Supply Authority) from the occupier or owner or of Supplier of the works. T he works shall be car ried out in accor dance with the approved drawing of the insta llation or the work complying with relevant provisions of the Regulations and the recommendations of the Indian Standard Code of practice. 3)For every Electrical Installation work carried out under regulation 29 of Central Electricity Authority (Measures relating to Safety and Electric S upply) Regulations, 2 010, a Test – Report with relevant dra wing shall be submitted by the Contra ctor to the concerned Electric Supply Author ity. The test shall be carried out in the presence of the Supervisor and the Test- Report shall be signed by the Supervisor under whose supervision the work had been carried out and shall be countersigned by the Contractor. T he Supervisor shall be wholly responsible for the correct execution of the electr ical installation work as per the relevant pr ovision of the Regula tions a nd the recommendation made from time to time by the Indian Standard Instit utes. In addit ion, the Contra ctor shall fur nish a copy of the Test-Report to the electric supply authority as well as to the Electrical Inspector having jurisdiction. Provided tha t notice for internal wiring works upto 20kW load may be given to the SDO (P&E) concerned only.Ex-62/2017 13 44. Change of name(Firm/Body): 1)Any firm or body holding a Contractor ’s License of any class may make an application to the Secr etary along with the fee prescribed in the Schedule of fees appearing in Annexure- I for effecting a ny change in the name of the firm or body and the Secreta ry may, with t he appr oval of t he Chairman, a llow such change provided it does not involve any transfer of assignment of the License to any other person, firm or body. 2)Where any change is a llowed under the pr oceeding Sub - R egulation, the Secreta ry sha ll make endorsement to this effect under his hand and sea l with date in the License as well a s in the r ecords of the Board. 45. Suspension, Revocation of certificate/Licence: The Board ma y direct the su spension or revocation of a certifica te/Licence/Permit, if the Boar d is satisfied that the holder:- a) has committed a breach of a ny of these conditions or : b) has committed a breach of any conditions stated in the Certificate/Licence/Permit as the case may be; or c) has failed to furnish any information or record to the Electrical Inspector which he has required for the purpose of satisfying himself whether any provision of the aforesaid condit ions ha s been complied with or whether any order of the Electrical Inspector has been car ried out or d) has been guilty of such mis-conduct as t o render the suspension or revocation of the certificate/license/permit is justified and desirable in public interest or: e) has shown inefficiency or negligence in the execution of electr ical works. 46. Board Decision to be final: The decision of the Board in all matters relating to the examination of candidates for grant of Permit, Certificate of competency and to issue renewal, suspension and revocation of Permit/Certificate of competency/ Electrical Contractor ’s Licence, imposition of penalty, etc. shall be final. 47. Matter not specified in the Regulation: The Board may cons ider and make suitable decision in matters which are not clearly specified in the Regu la tion. 48.Repeal and Saving: On a nd from the commencement of these regulations, T he Mizoram Electr ical Licensing Regulations 2003 published in the Mizoram Gazette Extra Ordinary Issue No. 243, dt 1.9.2003 under Notification No. B.16012/24/2000-P&E, dt.27.8.2003 (As amended in 2010) shall stand repealed. Provided that any order made or anything done or any action taken under the Regulations so repealed shall deemed to have been done or taken under the corresponding provisions or these r egulations. 49. Accounts : 1.The financial year of the accounts shall be from 1st Apr il to the following 31st Ma rch. 2.The Board shall, in respect of the Licensed Contractor/Supervisor/Workman, keep such acou nting records a s would be required so that the revenue cost, assets, liabilities, reserve and the provisions for, or resonably attributa ble to the Licensed Contractor /Supervisor/Wor kman are separately identifiable in the book of the Electr ical Licensing Board, and 3.The Board shall, upon the request by any person/authorized body, make available a cop y of each accounting statement a t a price not exceeding its photo copying charges. Secr etary to the Government of Mizoram, Power & Electricity Department, Aizawl, Mizoram. Ex-62/201714 ANNEXURE-I SCHEDULE 0F FEES(See regulation 15) 1. Fees for Electrical Contractor’s License: Class ofInitialRenewalLateDuplicateIncrease ofChangeContractorfeefeerenewalLicense feescopeoffee perfeenamemonthClass-IRs 4,000Rs. 1,500Rs. 500Rs. 1,000-Rs. 1,500 Class-IIRs 3,000Rs 1,000Rs. 500Rs 1,000Rs.1,000Rs.1,500 2. Special Class (Temporary) Electrical Contractor ’s License: Class of WorkInitial FeeDuplicate License feeUp to 650 VRs. 5,0002,000 Above 650 v & up to 33KVRs.10,0002,000 Above 33 KV Rs.15,0002,000 3.Fees for Electrical Supervisor’s Certificate ( S ee Regulation 29,30 & 31): Initial feeExaminatio n feeRenewal feeLate renewalDuplicatemonthfor each class per year fee perCertificate feeRs.500Rs.150Rs.200Rs.100Rs.300 4.Fees for Electrical Workman’s Permit (See regulation 32, 33 & 34): InitialExaminationRenewal feeLate renewalDuplicatefeefee for eachclassper yearfee permonth Permit feeRs.350Rs.100Rs.150Rs.100Rs.250 Notes:- 1.An Electrical Contractor holding a valid License granted under these Regulations and desires to increase the scope of his wor k shall submit a fresh application in Form - A 2.Should a passed candidate desires to qualify, subsequently for a class other tha n that for whic h a cer t ifica t e or p er mit ha s b een gr a nt ed, h e will b e p er mit t ed t o a p p ea r in t he ex a mina t ion for the parts concerned. S imilarly, those who apply for exemption from examina tion and who have been granted a Permit/ Certificate for one class or more classes may apply with the requisite fee for examina tion in any other additional class or Classes. 3.All Fees levied under these Regulations shall be paid to the Secretary. 4.Printed copies of these regulations may be obtained from the Secretary, on payment of the cost. 5.Forms of applications may be obtained from the Secretary, Mizoram Electrical Licensing Boa rd.Ex-62/2017 15 ANNEXURE-II [See regulation 29 (3)] SYLLABUS FOR ELECTRICAL SUPERVISOR’S CERTIFICATES EXAMINATIONS Part-1 ELEMENTARY PRINCIPLES1.Principles of Electricity: Electric pr essure, current and r esistance, Ohm’s Law, Kirchhoff ’s La w, calculation of voltage drop, series and parallel circuits, unit of voltage, current, resistance, power and energy, relation between electrical unit (kW) and mechanical power unit (HP), inductance, capacitance, reactance and impeda nce. 2.Electromagnetism: Flux, flux density, magnetic field strength, permeability, magnetic circuits; reluctance, calcula tion of MMF, effect of air gap, hysteresis loop of magnetic materials, Electroma gnetic Inducta nce, production of EMF, Fleming’s Hand Rules, Faraday’s Laws, Lenz’s Law, Self and Mutual Inductance, Coupling coefficient, magnetic properties of materials, Electro-magnets and their applications. 3.Materials: Conductors, non-conductor s, insulators, insulating materia ls a nd their utilit ies, tr ansformer oil, effect of heat and moistur e on insulation, dielectric, permittivity, different types of wir es, cables, switches, circuits breakers, fuses. 4.Generation of Electricity: Method of genera tion of electric power, block s chematic layout of generating station; Hydro - electric, T hermal and Nuclear sta tion. Non-conventional Energy sources, solar power, wind power. 5.Acts and Regulatio ns: Wor king knowledge of: 1)The Electricity Act, 2003. 2)The Central Electricity Authority (Measures relating to Safety and Electric Supply) Regulations, 2010. 3)The Mizoram Electr ical Licensing Regulations, 2 017. 4)The relevant Joint Electr icity Regulatory Commission for Manipur & Mizoram Regulations such as: i)Electricity Supply Codeii) Consumers Grievances Redressal Regula t ions iii)Prevailing Power Tar iff. Part-2 WIRING FOR SYSTEM NOT EXCEEDING 250 VOLTS1.Do mestic Installation: Various types of LT wiring - cleat, casing and capping, metal sheathed, condu it, types of wires, cables and their standard sizes with current carrying capacities, estimates of materials and cost of different types of installations, load survey, connected load, maximum demand, main switch board, distribution board, location of switch board, distribution layout a nd circuit dia gram, s election of fuses, M.C.C.B.(Moulded Case Circuit Breaker) Ex-62/201716 2.Illumination: Char acteristics of different types of lamps, inca ndescent lamps, fluorescent lamps, vapors la mps, HPSV (High Pressure Sodium Vapour), LPSV (Low Pressure Sodium Vapour), LED (Light Emitting Doide), magnetic induction lamp, energy efficient lamps, photometric unit and their measurement. 3.Earthing : Resistivity of soil and their measurement, computation of ear th resistance, differ ent materials used for earthing conductors, corrosion fact or, determination of size of earth bus, pla te, pipe and s trip earthing. 4.Installation testing and measurement: Insu la tion tester, earth t ester, ammeter, voltmeter, wattmeter, ener gy meter with M DI (Max imum Dema nd Indicator) facility, recommended va lue of insulation resistance, earth r esistance, pola rity test, continuity test, insulation test, earth resistance test, detection and location of faults. Part-3 WIRING FOR SYSTEM NOT EXCEEDING 650 VOLTS1.A.C. Circuits : Alternating current fundamentals, gener ation of alt ernating cu rrent, different wave forms, frequency, time period, average value, rms value and form factor, phasor representation of alternating quantities, rectangular, polar and exponential forms, analysis of simple AC circuits with resistance, induct ance and capacitance, concept of impedance a nd admittance, phasor representation, power and power fact or in AC circuits, active and reactive component, solution of R-L (Resistance-Indu ctance), R-C (Resistance-Capacitance), and R-L-C (Resistance-Inductance-Capacitance) circuits, series, parallel and series-parallel circuits. 2.Three phase system : Star and Delta connection, relationship between p hase and line value of voltage and current, phase repr esentation, solution of bala nce and un-bala nce thr ee phase circu its. 3.Symbols: List of symbols, preparation of electrical wiring diagram and electr ical cir cuit diagrams, reading of electrical diagrams. 4.Special types of equipments: X-Ra y, Neon-sign, lift, escalators, cinema installation, relevant rules, cir cuitry, safety precaution, earthing, fire precautiona ry measures for the above inst allation. IS 4878/91-C ode of practice for cinema installation. Part-4 AC& DC APPARATUS NOT EXCEEDING 650 V1.AC Generators (Alternators) : Basic principles, detail construction a nd essential component, volta ge regulation, method of voltage control a nd frequency contr ol, synchronizing of alternators, syncroscope, bright lamp and dark lamp method, associated switch board and its a ccessor ies.Ex-62/2017 17 2.DC Generators: Basic principles, detail construction and essentia l component, shunt, series and compound generators and their cha racteristics, commuta tors and their maintenance, car bon brushes-their adjustments and care, voltage regulation, par allel operation, associated switch board and its a ccessor ies. 3.Batteries: Primary cell, dry cell, Lead acid and Nickel-Cadmium batteries, construction, characteristic, charging and discharging. Charging circuits and their calculation, series and parallel circuits. Specifications, maintenance, storage of batteries, use of hydrometers, battery charging equipment and their operation. 4.AC Motors: Three phase induct ion motors, construct ion principle of opera tion speed, fr equency, slip, star-delta star ting. Single phase induction motors, construction, different method of star ting. Squirrel cage induction motors, slip ring induct ion motors. Synchronous motor s, gener al principle of operation, uses, insta llation method of star ting and speed control and reversal of direction, commuta tor motors. 5.DC Motors : Motor principle, series, shunt and compound wound type motor, their uses, installation, method of star ting, speed control, reversal of direction. 6.Control Gears: Various type of switches, fuses, starters, contr ollers, regulators-their uses and installation. Earthing of motors and generators. 7.Conversion: Principle of opera tion of motors and generators. Rotar y or Synchronous converters. Mercury-Arc rectifiers, inverters. Thyr istors and other static devices. Filtering-Half wave, Full Wave, Br idge rectifier. Part-5 OVERHEAD LINES NOT EXCEEDING 650 VOLTS1.Cons tructio n of lines: Construction of low and medium voltage lines, size of conductor, length of span, sags, strength of poles, different types of poles. S pacing of conductor s, cross arms, effect of tempera ture, wind pressure, ice and snow. Tension of wire, insulators, bracket, stays, struts, guard wires, protective device. Ear thing, lightning arrestors and lightning conductors and their test ing. 2.Operation: Test ing and fault location, methods of working on overhead lines, inspection of distribution lines. Three wires and four wires system. Power in three phase system. Phase sequence. Measurement of active and reactive power in single phase and three phase sys tem. 3.Clearances: Statutory clearances of live parts from ground and building. Sectional clearances, equipment clea rances. Cleara nce of switch board, oil containing equipment, indoor and outdoor equip ment clea ra nc es . Ex-62/201718 Part-6 OVERHEAD LINES NOT EXCEEDING 33,000 VOLTS1.Cons tructio n of lines: Construction of high volta ge lines. Sizes of conductor with cur rent ca rrying capacity. Length of span, sags, strength of the poles, differ ent type of poles. Design of different type of tower and their constr uction, erection and str inging of conduct or . Spacing of conduct or, cr oss arm, effects of temperature, wind pressure, ice and snow. Tension of wires, insulators, vibration dampers, brackets, stays, struts, guar d wires, protective devices. Earthing, lightning a rrestor and lightning conduct ors, and their testing. 2.Clearance: Statutory clearance of the live pa rts from ground and bu ildings . Sectional clearance, equipments, oil containing equipments. Indoor and outdoor equipment cleara nce. 3Operation: Methods of working on over head lines. Equipments used for r eplacement of insulators, their rating, method of r eplacement of insulators. Inspection of Tra nsmission lines. Line consta nts, determina tion of voltage drop. Voltage regulations. Effect of power factors and their improvement. 4.Transmission: Bulk Transmission of electric power. Typical power transmission scheme. Need for high transmission volt age. Pr imary and secondary tr ansmission systems. Part-7 UNDERGROUND CABLES FOR VOLTAGE UP TO 650 VOLTSBasic knowledge of different types of cables- PVC (Poly Vinyl Chloride), APVC. Genera l pract ical knowledge of laying cables; direct in ground, in troughs and in pipes, handling, bending, jointing, plumbing. Underground and above ground junction boxes. Distr ibution boxes and pillars. Joint box compounds, melting of compounds, fillings boxes with compounds. Part-8 UNDERGROUND CABLES FOR VOLTAGE UP TO 33,000 VOLTSBasic knowledge of different type of cables-AYFY, XLPE (Cross linked Poly Ethylene), oil filled, gas filled and any other t ypes. Testing and fault location, Murray Va rley loop test s. Current ratings- shor t time ratings and continuous rating. Dera ting factors of cables. Calculation of voltage drop. Alluminium and copper cable jointing- types, precaution, termination. I.S. Regulations regar ding cables. Part-9 INSTALLATIONS NOT EXCEEDING 33,000 VOLTS1.Switch Gear and Protection: Knowledge of various type of switches, protective fuses. Circuit breakers- OCB (Oil Circuit Breaker), VCB (Vacuum Circuit Breaker), ACB (Air Circuit Breaker), MCCB (Moulded Case Circuit Breaker), SF 6 (Sulphur Hexa F louride) Breakers, thermal and magnetic release Relays,Ex-62/2017 19 Buchholtz Relays, IDMT (Inverse Definite Minimum Time Relay), Instantaneous type. Over current, eart h fault and ea rth lea ka ge relays, t ime and current setting. HRC fuses, paper b arrel a nd HV fuse- use and construction. Lightning arresters, isolators Bus bar, D.O. (Drop-Out)cum Gang Switch, hook sticks. Earthing of S ub-Stations. 2.Transformers: Tra nsformer s – construction, use a nd maintena nce. Voltage and cu r rent r elations. Losses andefficiency. Par allel operation of three pha se transformers. Three phase transformer connections- Star/Star, Delta/Delta, Star/Delta, Delta/Star. Auto transformers, transformer tappings. 3.Instrument Transformers: Curr ent transformers (CT); specifications and err or fact ors. Potential transformers (P Ts). 4.Selection of Equipments: Different types of breakers- OCB, VCB, ACB, MCCB, MCB, SF 6 Breakers. Contactors, Breaking capa city, Ma king Ca pacity, Selection of Br eakers. Select ion of switches; Short time and continuous ratings. Power Factor cor rection by ca pacitor s. Shunt React ors. 5.Connections: Method of connection of special t ype Transformers, Rectifier tr ansformers. Welding tr ansformers. Determination of capacity, load segregation, Double bus system. Change over arrangements. Preparation of schematic diagra m of Sub- Station. 6.Energy Measurements: Measurement of power, Watt meters, Energy meters, Trivect or meters. Computation of Energy. 7.Clearances: Statutory clearances of live parts from ground. Sectional clearances, equipment clearances. Clearances of oil containing equipments. Part – 10 VOLTAGE RANGE: EXCEEDING 33,000VOLTSType of installation : Overhead lines and installations a voltages exceeding high pressure 33,000 volts. 1.General : Knowledge of conductors, supports, cross a rms, insulator s and other lines accessories used in H.T. Line constr uctions, application a nd uses, making bills of materials, basic knowledge of common types of ra ting of transformers used in power supply system- types, r ating, used of common Sub- Sta tion equipment such as cir cuit breakers, distr ibution pillars, lightning arrestors, bushing for transformers and other equipment, CTs and PTs. 2.Cons truction : Methods of construction of overhead line exceeding 33,000 volt s; conductor, jointing, jumpering and knowledge of configuration of conductors, clearances, sag, spans etc. insta llation of pole and floor mounted transformers and associated sub-sta tion equipment, installation of circu it breakers, isolators, gang operated switches and fuses, etc. Ex-62/201720 3.Service connection at high Voltage: Use and installation of CTs & PTs for High Pressure Metering. 4.Testing : Methods of t esting overhead lines and sub–station equipments, fault testing, location a nd rectification. 5.Earthing: Knowledge of practices and procedures of earthing for H.T. (High Tension) Overhead line equipment and sub-stations. 6.Working procedures : Line cleara nce procedures – safe working practices for High Voltage overhead line installations, intimate knowledge of electrical shock treatment methods and procedures. 7.Maintenance : Methods of maintenance of overhead lines, sub-sta tions, sub-sta tion equipment, transformers - oil test ing and filtration. 8.Regulations and codes of practice: Familiarity with the relevant Central Electricity Authority (Measures relating to Safety and Electric Supply) Regulations,2010 a nd National Codes of practice, R.E.C. standa rds and Codes of pract ice. ANNXURE-III [see regulation 32 (3)] SYLLABUS FOR ELECTRICAL WORKMAN’S PERMIT EXAMINATIONS Part-1 ELEMENTARY PRINCIPLES1.Principles of Electricity: Concept of voltage, current, resistance, inductance, capacitance, reactance, power, energy and power fact or. Comparison between series and para llel connection of loa ds. Simple calculation of curr ent, power energy and voltage drop. Units of voltage, current, resistance, power and energy. 2.Materials: Properties of conductors, non- conductors and insulators. Properties of copper and aluminum conductor. Insulating materials a nd their utilit ies such as PVC, rubber and porcelain. Different types of wires, ca bles, s witches , cir cu it brea ker, fu ses. 3.Drawing and Circuits: Reading of schematic diagram for internal wirings and control circu its. St andard symbols of var ious types of electrical equipments. Wir eman tools and accessor ies. 4.Safety measures: Safety measures to be observed while working on live parts. Devices used for wirema n’s safety. Action to be taken in case of electrical accidents. 5.Rules and standards: Knowledge of prevailing power tariff. Procedure for availing electric supply to consumers. Submission of test reports/Completion reports.Ex-62/2017 21 Part-2 WIRING FOR SYSTEM NOT EXCEEDING 250 VOLTS1.Domestic installations: Various types of wiring – cleat, casing and ca pping, metal sheathed, conduit. Types of wires, ca bles and their standard sizes with curr ent carr ying ca pacities. Main switch board, distribution boa rds, loca tion and clear ance of switchboards. Distribution layout and cir cuit diagram. Different types of fittings, a nd switches; use of test lamp. Connection and diagra m of distribution boar ds, ceiling rose, plugs and sockets, lamp holders- incandescent and fluorescent la mps, fa ns with regulators, two way switches. 2.Protection: Overload protection, earth leakage protection, permissible load, select ion of fuses-r ewirable and HRC (High Rupturing Capacity) types. Circuit Breakers, M.C.C.B. 3.Illumination: Characteristics of different types of lamps. Incandescent lamps, fluorescent lamps, compact fluorescent lamps (CFL), LED. 4.Earthing: Earthing of systems. Necessity of earthing .Types of ear thing. Selection and location of earthing .Types of size of earthing conductor. 5.Installation testing and measurements: Insulation tester, Earth tester, energy meter with MDI. Recommended values of insulation resistance, earth resistance. Polarity test, Continuity test, Insulation test, Earth resistance test. Part-3 WIRING FOR SYSTEM NOT EXCEEDING 650 VOLTS1.Three phase system: Relationship between phase and line values of voltage a nd current. Wir ing of three phase sys tem. Star and delta connection. Selection and identification of different cables and conductor. Protective system used in internal wiring. Use of b ell and battery for sorting out in circuits. Method of testing pola rity and phasing out circu its. 2.Jointing and soldering: Making straight and T joints in solid and stranded conductors a nd soldering them. Soldering p lugs and sockets, wires and ca bles and insulating t hem. 3.Symbols: List of symbols. Prepara tion of simple electr ical wiring diagrams and electrical circuit diagr ams. Reading of s imple electrica l circuit diagr ams. 4.Tariffs: Knowledge of prevailing power tar iff. 5.Special type of equipments: X-Ra y, Neon- sign, lift, Escalators,Cinema insta llations: Circuitry, Safety Pr ecaution, Earthing, Fire Precaution measure for the above installa tion. Wiring of specia l equipment like UPS, Inverters, Stand by for computers, etc. Essential factor for wiring High Rise Building. Ex-62/201722 Part-4 AC& DC APPARATUS NOT EXCEEDING 650V1.AC&DC Generations: Basic principle, construction and components. Commutators and their maintenance. Carbon brushes- their adjustments and care. 2.Batteries: Primary cell, Dry cell, lead a cid a nd Nickel – Ca dmium batteries; constr uctions, charging and discharging. Maintenance of storage of batteries. Use of hydrometers. 3.AC Motors: Three phase induction motors, construction, principle of operation. St arters- Direct on line and star- Delta starting. Single pha se induction motors-construct ion. Different types of fan regulators- resistant and electronic types. Pr inciple of opera tion of fra ctional Horse Power motors used in appliances, such as mixers, washing machines, etc. 4.DC Motors: Motor principle, their uses, installations, methods of starting, reversal of direction. Part-5 OVERHEAD LINES NOT EXCEEDING 650 VOLTS1.Cons tructio n of lines: Construction of low and medium voltage lines, use of safety and protective devices. Size of conductor, length of span, sa gs. Different types of poles, pole concreting and erection. Spacing of conduct ors, fixing of cross ar ms. Jointing a nd binding of conduct ors. Fitting of different types of insulators, brackets, stays, struts, guard wires. Earthing of over head lines, fitting of light ning ar restors and lightning conductors and their importa nce, service connections. 2.Operation: Methods of working on over head lines. Ins pection of dis tribution lines. Three wire and four wire systems. 3.Clearances: Statutory clearances of live parts from ground and buildings. Sectional clearances, equipment clearances. Clearance of switch boa rds. Part-6 OVERHEAD LINES NOT EXCEEDING 33,000 VOLTS1.Construction of Lines : Construction of high voltage lines. Use of safety and protective devices. S izes of conductor, length of span, sa gs. Different types of poles, strength of poles, pole concreting and er ection. Spacing of conductors, tension of wir e, fitting of cross a rms, fitting of insulators, vibration damper brackets, fitting of s tays, struts, guard wires. Ea rthing, fitting of lightning arrestor s and lightning conductors and their testing. 2.Clearances : Statutory clearances of live parts from ground and buildings. Sectional clearances, equipment clea rances. Cleara nce of oil containing equipments.Ex-62/2017 23 3.Operation: Methods of working on overhead lines. Equipment u sed for replacement of insulators, their ratings. Methods of replacement of insulators. 4.Transmission: Bulk transmission of electric power. Typical power tr ansmission scheme. Need for high transmission volta ge. Part-7 UNDERGROUND CABLES FOR VOLTAGE UP TO 650 VOLTSBasic knowledge of different types of cables- PVC, APVC. General practical knowledge of laying ca bles direct in ground, in troughs and in pipes, handling, bending, jointing, plumbing. Underground and above junction boxes. Distribution boxes and pillars, joint box compounds, melting of compounds, filling boxes with compounds. Part-8 UNDERGROUND CABLES FOR VOLTAGE UP TO 33,000 VOLTS Basic knowledge of differ ent types of ca bles – AYFY, XLPE, oil filled, gas filled and any other types. Current rating – short time rating and continuous rating. Calculation of voltage drop. Aluminium a nd copper cable jointing- types, precautions, termination. I.S. Regulations regar ding cables. Part-9 INSTALLATIONS NOT EXCEEDING 33,000 VOLTS1.Switch Gear and Protection: Knowledge of various types of switches, protective fuses, circuit breakers- OCB, VCB, ACB, MCCB, MCB, SF 6 Breakers. Over cur rent, earth fa ult and earth leakage relays and their settings. HRC fuses, paper barrel and fuses – use and construction. Lightning Arresters, isolators, bus bar, D.O. cum Ga ng Switch, hook stick. Earthing of sub-stations. 2.Transformers: Transformers- construction, use and maintenance. Voltage and current relation. Three phase transformer connections- Star/Star, Delta/Delta, Star/Delta, Delta/Star. Transformer tappings. 3.Instrument Transformers: Curr ent transformers, CT specifica tion. P otential Transformers, PTs. 4.Energy Measurements: Measurement of power, Watt meters, Energy meters, Trivector meters. Computation of energy. 5.Clearances: Statutory clearance of live parts from ground. Sectional clearance, equipment clearance. Clear ance of oil cont aining equipment. Ex-62/201724 Part – 10 VOLTAGE RANGE : EXCEEDING 33,000 VOLTS. Types of installation :Overhead lines and installa tions at voltages exceeding 33,000 volts. 1.General: Knowledge of conductors, supports, cross arms, insulators and other line accessories used in H.T.line cons tructions, application and uses, making bills of ma terials. Basic knowledge of common types and rating of transformers used in power supply system-types, ratings and use of common sub- station equipments such as isolators, circuit breakers, distribution pillars, lightning arrestors, bushing for transformers a nd other equipment –CTs and PTs. 2.Construction: Methods of construction of overhead lines exceeding 33, 000 volts, conductor, jointing, jumpering and knowledge of configura tion of conductors, clearances, sag, spans etc. erection of poles and floor mounted transformer and associated sub-station equipment, installation of circu it breakers, isola tor s. 3.Service connection at high voltage : Use and installation of CTs & PTs for high pressure metering. 4.Testing : Methods of testing overhead lines and sub-station equipment, fault testing, location and rectifica tion. 5.Earthing : Knowledge of pract ice and procedures for H.T. overhead line equipment and sub-stations. 6.Working procedure : Line cleara nce procedures- safe working pra ctice for high volt age over head lines insta lla tion. Intimate knowledge of Electrical shock t reatment methods and procedures. 7.Maintenance : Methods of maintenance of overhead lines, sub-station, sub-sta tion equipment, transformer -oil, test ing and filtration. 8.Regulations and Code of practice: Familiar ity with the relevant Central Electricity Authority (Measur es relating to Safety and Electric Supply) Regulations, 2010 and National Codes of practice, R.E.C. standards and code of practice.Ex-62/2017 25 ANNEXURE-IV FORMS FORM-A [See regulation 15] APPLICATION FOR ELECTRICAL CONTRACTOR’S LICENCE (For new Licence/Special Class/Increase in scope of work) 1.Name of fir m in which an Electr ical: …………………………………………… Contractor ’s License is applied 2.Business a ddress with phone number: ………………………………………..…. …………………………………….…….. 3.Full name of the proprietor: ……………………………………….….. (in capital lett ers) 4.Home address with phone number: …….………………………………..….... …………………………………………… 5.Date of Birth of proprietor: Date………. Month …….… Year………. (Attested photocopy to be enclosed for Proof of a ge) 6.Class of License applied for: ……………………………………………. Class-I or II/Special Class 7.Previous License No., if any:…………………………………………….. 8.a)Existing class of work ……………………………………………. b)Increase in scopes of work applied for ………………………………...…………. 9.For Special Class Electrical Contractor’s License only a) Name and location of work for which the License is applied for : …….……………………………………… b) Expected duration of completion of the work ……………………………………….. c) Duration / period for which License is required …………………………………..... 10. Deta ils of Electrica l Supervisors holding : 1)Name ………………………………… valid certificate in theCertificate No………………………..… employ of the applicantDate of expiry:………………………… 11. Deta ils of Electrica l Workmen holding : 1)Name:…………………………………... valid permit in the sole and wholePermit Number:………………………… time employ of the applicantDate of expiry:………………………….. 2)Name:…………………………………... Permit Number:…….………………… Date of expiry:………………………......…Recent passport size photo Ex-62/201726 12. Paid Rs ……….… vide receipt No……...…….. Dt……/...../… to the Secretary 13.Instrument in my possess ion are as follows: Sl. NoName of instr umentMaker’s nameSerial numberRemar ks 12345 I……………………………………….hereby declare that the particulars stated above are correct to best of my knowledge. I fully understand the Terms and Conditions under which a n Electrical C ontract or ’s License is granted, a breach of which will render the license liable to cancellation. Signature Date ……………………………Name:……………………… Note: 1)The applicant shall submit attested photocopy of Voters ID Card/Electricity Bill/ Telephone Bill/ Bank Pass Book/Ration card for proof of addr ess. 2)Any person who make or assist in making false representation for the purpose of obtaining an Electrical C ontract or ’s License himself is liable to be prosecuted. 3)Two copies of recent passport size photographs of the a pplicant should accompany the applica tion DECLARATION BY ELECTRICAL SUPERVISORThis is to declare that I (name in capital letters) …………………………………………… holding valid Electrical Supervisor ’s Certificate No …………………………is not regular/work-charged/officiating/ cont ract/ muster roll employee of any Government Department/undertaking or regular or full t ime employee of any company or firm. I am willing to work under (name or firm)s…………………………………...…as an Electrical Supervisors. Signature Date:…………………Full name……………………………………. DECLARATION BY ELECTRICAL WORKMANThis is to declare that I (name in capital letters) ……………………………………………… holding valid Elect rical Workman Permit No……………………………. is not a regular/work-charged/contr act/ muster roll employee of a ny Government department/Undertaking or a regular or full time employee of any company or firm. I am willing to work under (name of firm) M/s……………………………..……as an Electrical Workman. Signature Date………………..Full Name…………………………………….Ex-62/2017 27 FORM-B [See regulation 29 (1)] APPLICATION FOR ELECTRICAL SUPERVISOR’S CERTIFICATE EXAMINATION 1.Full name of the applicant (in capital letters):……………..………………. 2.Father’s name:……………………………… 3.Date of birth: Date…....... Month ........… Year…....… 4.Perma nent address in full:.……………………………… with phone no……………………………….. 5.Present addr ess in full with phone no.:……………………………… 6.Deta ils of technical qua lifica tion:………………………………. 7.Fees payable: 1) Initial fee – Rs. 500.00 2) Examination fee Rs.150 for each class: Receipt No…...........dt…............. 8.Class for Examina tion:………………………………. I hereby declare that the particulars stated a bove ar e correct and true to the best of my knowledge and believe. Date…………………. Signature of Applicant Note: 1)Attested cop y of document showing date of birth should b e submitted with the a pplication. 2)Attested copy of the technical qualification to be submitted with t he application. 3)Original copy of the certificate should be produced at the time of interview. 4)Two copies of recent passport size photographs of the applicant with name and signature on the back should accompa ny the application. 5)Any person making false statement shall render himself liable for prosecution. 6)Selected Ca ndidates will have to pay initial fee for obtaining Supervisor ’s C ertificate. INCOMPLETE APPLICATION WILL BE REJECTED.Recent passport size photoEx-62/201728 FORM-C [See regulation 32 (1)] APPLICATION FOR ELECTRICAL WORKMAN’S PERMIT EXAMINATION 1. Full name of the applicant (in capital letters) :…………….……………………….… 2. Father’s name:…………..………………………..….. 3. Date of birth: Date…………Month…….. Year……. 4. P ermanent address in full with phone no:……………………………….……….. 5. P resent address in full with phone no.:………………………………….……... 6. Details of technical qualifica tion:…………………………………………. 7. Fees payable :1) Initial fee – Rs.350.00 2) Examination fee Rs.100 for each class Receipt No……….. dt. ………….... 8. Class for Examination :……….……… I hereby declare that the particulars stated above are corr ect and true to the best of my knowledge and believe. Date…………………. Signature of Applicant Note: 1)Attested cop y of document showing date of birth should b e submitted with the a pplication. 2)Attested cop y of the technical qua lification to be submitted with the application. 3)Original copy of the certificate should be produced at the time of interview. 4)Two copies of recent passport size photographs of the applica nt with name and signa ture on the back should accompa ny the application. 5)Any person making false statement shall render himself liable for prosecution. 6)Selected Ca ndidates will have to pay initial fee for obtaining Supervisor ’s C ertificate. INCOMPLETE APPLICATION WILL BE REJECTED.Recent passport size photoEx-62/2017 29 Form D (See Regulation 16) Sample of Electrical Contractor’s Licence Front Page GOVERNMENT OF MIZORAM MIZORAM ELECTRICAL LICENSING BOARD ELECTRICAL CONTRACTOR’S LICENSE No. MELB/C-……/………./…… Firm : ……………………… Pr opr ietor : ……………………. Date of birth : …………../……./………….. Address :………………………………. Valid up to : ……./………../20……. Back page CLASS AUTHORISED TO WORK Secretary MIZORAM ELECTRICAL LICENSING BOARDRecent passport size photo withNote :- In case of new Electrical C ontract or License, Secretary will issue after obtaining approval of the Chairman through file.Ex-62/201730 Form E [see regulation 30 (1)] Sample of Electrical Supervisor’s Certificate Front Page GOVERNMENT OF MIZORAM MIZORAM ELECTRICAL LICENSING BOARD ELECTRICAL SUPERVISOR’S CERTIFICATE MELB No …. /S/……/….. Name:................................................. Date of birth:........................./.........../.................... Address:.......................................................... Valid up to:.............../................./20.................. . Back page CLASS AUTHORISED TO WORK Secretary MIZORAM ELECTRICAL LICENSING BOARDRecent passport size photo with signatureEx-62/2017 31 Form F [see regulation 33 (1)] Sample of Electrical Workman’s Permit Front Page GOVERNMENT OF MIZORAM MIZORAM ELECTRICAL LICENSING BOARD ELECTRICAL WORKMAN’S PERMIT N0.MELB …../W/……/…… Name: ……………………… Date of birth : …………../……./………….. Address:………………………………. Valid up to: ……./………../20……. Back page CLASS AUTHORISED TO WORK Secretary MIZORAM ELECTRICAL LICENSING BOARDRecent passport size photo signatureEx-62/201732 Form G [see regulation 32(1)(ii)] Certificate to be granted to Electrical Staff for admission to Electrical Workman’s and Electrical Supervisor ’s examination. 1.Name of Employee ( in capital letters ) : 2.Date of Employment: 3.Date of discharge, if discha rged : 4.Nature or Work in which engaged : 5.Skill in t he work in which engaged: 6.Conduct : 7.General Remarks : I here by declare that the particulars stated a bove ar e correct and true to the best of my knowledge. Date:……………Signature of Employee / Licensed Electrical Contractor Seal Note :- 1)This Certificate should b e granted only to persons who are or have been actually employed on Electrical Wiring and installation works and whose names are entered in the regist er of wiring staff in F orm - H mainta ined by every Licensed Electrical Contractor. 2)Issue of false Certificate will render the Licensed Electrical C ontract or and t he person concerned liable for a ction a gainst them. 3)The employer or the Licensed Electrica l Contractor shall, if required by the Secretary, be responsible for producing docu mentary evidence regar ding the applicant’s employment.Ex-62/2017 33 Form-H [See regulation 19] Detail of Electrical Supervisor, Workman & Apprentices Name of Contractor : License No : Period from Dt. ……./……./……. to Dt. ......../……../… Sl.NoNamePermit/Date ofDate ofRemar ks ofCertificateEmploymentDischarge EmployeeNumber if any 1 2 3 4 5 6 Place: ..................................Signature of Contra ctor Date............/………/……...SealEx-62/201734 Form –I Return of Work Done [See regulation 19] Name of Contractor : License No : Period from Dt. ....................... to Dt. ...................... Sl.No Name of workName ofName ofDate ofTotalTest r epor t with address/supervisor withWorkmanCom- LoadSubmitted to locationcertificate NoWith permit pletion No 1234567 Place :…………………………Signature of contra ctor Date : ……./……………./…SealEx-62/2017 35 Form J [See Regulation 18 (1)] APPLICATION FOR RENEWAL OF ELECTRICAL CONTRACTOR’S LICENCE 1. Name of Applicant ( in Capital ): ...................................................... 2. Detail Address with phone Number: ....................................................... 3. Name of firm: ....................................................... 4. License Number: .......................................................... 5. Date of Expiry: ........................................................... 6. Name of Supervisor with Certificate no: ........................................................... 7. Name of Workma n with permit Nos.: …….................................................... 8. Renewa l fee: (as per Schedu le of fees):………………….. 9. Late Renewal fee, if any (as per Schedule of fees) ……………. 10. Enclosures: 1. Form - H. List of employee 2. F orm – I. Return of Work Done Date ..................................Signature of Contra ctor SealRecent passport size photo signature Ex-62/201736 Form – K Notice before Commencement of works [See Regulation 23(b)] Work Sl/no : ...................................... Date : ......................... 1.Name of Contr actor: ................................... 2.License no: .................................... 3.Detail of wor k to be done: ................................... ( Attach electrical Drawing ) 4.Full address work to be done: ....................................... ....................................... ....................................... ...................................... 5.Tentative da te of starting work: ...................... 6.Expected date of completion of the work: ....................... 7.Name of supervisor with certificate No: ...................... 8.Names of wor kman with permit no: ...................... Date ........./........../......…Signature of Contra ctor with seal. Note:- The contr act or shall submit copy of this Notice befor e commencement of work to the S.D. O. (P&E) concerned, the Electrical Inspector and the Secretary M. E.L.B. whenever a new work is taken up by him except for I phase and III phase internal wiring of load up to 20 KW. Notice for internal wiring works up to 20 kW load maybe given to the S.D.O. (P&E ) concerned only.Ex-62/2017 37 FORM – L [see regulation 31(1), 34(1)] APPLICATION FOR RENEWAL OF SUPERVISOR’S CERTIFICATE & WORKMAN’S PERMIT 1.Name of Applicant(in capital letters) :___________________________ 2.Deta il Address with phone number : ___________________________ ____________________________ 3.Certificate/Permit Number :____________________________ 4.Date of Expiry :Dt___/_____/____ 5.Present occupation with Address:_____________________________ :_____________________________ :_____________________________ 6.Renewal fee ( as per Schedule of fees )_________________ 7.Late renewal fee, if any ( as per Schedule of fees )____________ Date:______________Signature of ApplicantRecent passport size photo signature Published and Issued by the Controller, Printing & Stationery, Mizoram Printed at the Mizoram Government Press, Aizawl C-50Ex-62/201738
The Mizoram Gazette EXTRA ORDINARY Published by Authority RNI No. 27009/1973 Postal Regn. No. NE-313(MZ) 2006-2008VOL - XLVI Aizawl, Wednesday 8.3.2017 Phalguna 17, S.E. 1938, Issue No. 62 NOTIFICATIONNo.B.16013/24/2013-P&E, the 28th February, 2017.In compliance with the decision taken by Coun- cil of Ministers in its meeting held on 8th Feb. 2017 the Governor of Mizoram is pleased to notify Mizoram Electrical Licensing Regulations 2017 with immediate effect. This issues with the concurrence of Finance Department vide their I.D. No.FIN(E) 596/2016 dt.12.12.2016 and Law & Judicial Department vide their I.D No.LJD-33/2016/96 dt.13.7.2016. C. Lalhmachhuana, Secretary to the Govt. of Mizoram, Power & Electricity Department. Ex-62/20172 NOTIFICATION No B.16013/24/2013-P&E the 28th Feb. 2017. The Governor of Mizoram is pleased to order that grant of Licences to Electrical Contractors, Certificates of competency to Electrical Supervisors and Permits to Electrical Wor kmen shall be governed by the Mizoram Electr ical Licensing Regulation 2017 framed in accordance with Regulation 29 of Central Electricity Authority (Measures relating to Safety and Electric Supply) R egulations, 2010 namely - The Mizoram Electrical Licensing Regulations, 2017 1.Short title, extent and commencement: 1)These Regulations shall be called the Mizoram Electrical Licensing Regulations, 2017. 2)They shall extend to the whole of Mizoram. 3)They shall come into force from the date of publication in the official Gazette. 4)The words used in these Regulations shall have the same meaning as defined and assigned to them in the Electricity Act, 2003 and Central Electricity Authority (Measures relating to Safety and Electric Supply) Regulations, 2010. 2.Abbreviation and Definitions: 1)Chairman means Chair man of Mizoram Electrical Licensing Board. 2)Vice Chairman means Vice Chairma n of Mizoram Electrica l Licensing Board. 3)Secr etary means Secretary to the Mizoram Electrical Licensing Board. 4)Assistant Secretary means Assistant Secretary to the Mizoram Electrical Licensing Board. 5)Boar d means Mizoram Electrical Licensing Board. 6)MELB means M izoram Electrical Licensing Board. 7)Examination means examination conducted by Mizora m Electr ical Licensing Board for Supervisors Certificate and Workma n’s Permit. 8)MELR means Mizoram Electrical Licensing R egulations. 9)JERC means Joint Electricity Regulatory Commission for Manipur & Mizoram. 3.Constitution of Licensing Board: For carrying out the purposes of these Regulations, a Licensing Board namely “ the Mizoram Electrical Licensing Board” hereinafter r eferred to as “ the Boar d” shall be constituted by the State Government of Mizoram. 4.Members of the Licensing Board: The Board shall consist of the following members:- 1)The Secreta ry to t he Government of Mizor am, P&E Department-Chairman (Ex-officio) 2)The Joint Secretary (Technical) to the Government of Mizoram,-ViceChairman P&E Depart ment(Ex-officio) 3)The Chief Electrica l Inspector, Government of Mizoram-Secretary (Ex- officio) 4)The Electrical Inspector, Government of Mizoram- Asst. Secretary (Ex –officio) 5)Principal, Industrial Training Institute, Aizawl-Member 6)Repr esentative of Public Works Department, Mizoram to be nominated by the Department- Member 7)Repr esentat ive of Power & Elect ricity Department, Mizoram to be nominated by the Department- Member 8)Repr esentative of Pu blic Hea lth Engineering Department,- Member Mizoram to be nominated by the Department 9)General Manager, Dir ectorate of Indust ries-Member The State Government may add or r educe number of the members of the Board, other than the Ex-officio members. The Board shall have powers to act not withstanding any vacancy in its membership. 5.Place of office: The office of the Board s hall be situa ted in the sta te capital. 6.Functions of the Board: The functions of t he Boar d shall be - 1)to grant Licences to Elect rical C ontract ors; 2)to conduct examination for Electr ical Supervisors and Electrical Workman; 3)to grant Certifica tes to Electrical Supervisor and Permit to Electrical Workman; 4)to enquire into allegations of incompetence, negligence, violation of the Central Electricity Authority (Measures relating to Safety and Electric S upply) Regulations, 2010 or malpractice on the part of Workman/Supervisor/Contractor holding Permits/Certificates/Licences gra nted by t he Board or breach of conditions as may be considered necessary; 5)generally t o carry out the provisions of these R egulations; 6)to decide on the ca ses of violation of a ny of the provision of these regulations on any person/ group of people, Electrica l Contra ctors, Workman and Supervisor s as per Regula tion No 39; 7)to advise the State Government regarding all matter related to issue of licences, cer tificate or permits and any other matter; 8)to make Amendment of some or all of Mizora m Electrical Licensing Regulation. 7.Meeting of the Board and Quorum: 1)The Board s hall meet once in a year and at such times when the Secr etary feels necessary for transaction of business. 2)The Chairman or Vice Chair man and Secreta ry, together with three other members shall form a quorum at any meeting of the Board. 3)In t he absence of the Cha irman the Vice Chairma n will preside over the meeting. 8.Duties of the Chairman: The duties of the Chairma n shall be:- 1)to preside over meetings of the Board; 2)to take necessary actions to implement decisions of the Board; 3)to keep liaison between the Board and the Government. 9.Duties of t he Vice Chairman: to preside over the meetings of the Boar d in the absence of the Chairman. 10.Duties of the Secretary: The duties of the Secretar y shall be:- 1)to call a meeting of the Board in consultation with the Chair man; 2)to take necessary actions to implement decisions of the Board; 3)to r eceive applica tions of Contr actor ’s Licence, Supervisor ’s Certificate, Workman’s Permit and process them including conduct of examinations; 4)to sign and issue Contractor ’s Licence, Supervisor ’s Certificate, a nd Workman’s Permit . In case of new Licence, Certificate and Permit, Secretar y will issue after obtaining Chairman’s approval; 5)to maintain Registers of Contractor ’s Licence, Supervisor ’s Certificate and Workman’s Permit;Ex-62/2017 3 6)to make all correspondences on behalf of the Board regarding issues/r enewal/ allega tion etc, in r esp ect of Licences , Certif icates and Permits; 7)to place before the Boa rd/Chairman any matter regarding violation of C entral Electricity Authority (Measures relating to Sa fety and Electr ic Supply) Regulations, 2010 or condition of Licences/Certificates/P ermits by Contr actors/ Supervisors/Wor kmen or execution of works by person/contra ctor without valid licence issued by Mizoram Electrical Licensing Board, and can take appropriate action in accordance with the decision of t he Boar d to the viola tors of Mizoram Electrical Licensing Regulations. 11.Duties of the Assistant Secretary: The duties of the Assistant Secretary shall be:- 1)to assist the Secr etary in discha rge of his duties; 2)to act as Secretary in the absence of the Secretary. 12. Electrical Contractor’s Licence: 1)No electrical insta llation work shall be underta ken except by an Electrical Contract or licensed under these regulations read with Regulation 29 of Centr al Electricity Authority (Measures relating to Safety and Electric Supply) Regulations, 2010. 2)An Electrical Contr actor ’s Licence shall be granted only to a person/firmappr oved by the Board who:- a) himself holds an Electrica l Supervisor ’s Certificate or who ha s in his employ at least one S upervisor for Class – I and one Supervisor for class - II holding a valid Certificate granted by the Board a nd who is not a full time employee of a Government or a ny other agency; b)has in his employ at least two Electrical Workmen for class - I and one Electrical Workman for Class - II holding a valid Permit granted by the Board and who is not a full time employee of a Government or any other agency; c)is a permanent resident of Mizora m and not below 18 years of age; d)has in his possession the instruments prescribed for the class of contra ctor which he proposes to apply; e)has the following documents: The Electr icity Act 2003. The C entral Electricity Authority (Installation and Operation of Meters) Regulations, 2006. The Central Electricit y Authority (Measures relating to Sa fety and Electric Supply) Regulations, 2010. The Int imation of Accidents (Form and Time of Service of Notice) Rules, 2005. Mizoram Electrical Licensing Regulations, 2017. The relevant Joint Electricity Regulator y Commission for Manipur & Mizor am Regulations viz:- Electricity Supply Code and any other Notifications regarding regulations of electric supply issued by JERC for Mizoram and Manipur from time to time. f)Fulfill the condit ion laid down in the a pplication for m and pays the prescr ibed initial fee just after the application is approved by the Board. g)any other r equirement that the Board may prescr ibe from time to time such as proof of address of the Contractor ’s establishment, Financial capability, etc. Provided that the Board ma y refuse to gr ant such licence to any person (or firm/ body) who (or which) in the opinion of the Board, is not fit to hold such licence. The Electr ical Contractor ’s Licence is not tra nsfera ble. Ex-62/20174 13. Classes of Electrical Contractors: 1)There shall be three classes of Licensed Electrical Contractors namely Class - I, Class - II and Special Class (Tempora ry). 2)Class –I Electrical Contractor shall be eligible to undertake and carry out all types of Electrical works irrespective of voltage limit, subject to the limit of the Supervisor Certificate held by him or the Supervisor employed by him. The Scope of the wor k may be increased when the limit of the Certificate is increased by paying t he pres cribed fees. A Class - I Contractor ’s Licence may be granted to a person/firm/body who himself holds a valid Certificate of Competency issued under the regulations and a ctually works as a full time Supervisor in r espect of the works undertaken by him and at least two Workmen, each holding a valid permit issued under these Regulations, under his full time employment or to a person or a firm having at least one Supervisors, holding a valid Certificate of Competency issued under these Regulations and at least two Workmen, holding a valid permit issued under these Regulations under his or its fulltime employment provided such person or firm has in his/its possession a ll the instruments and tools of the B.I.S. standard in adequate number for carrying out the test and exa minations . 3)The Contractor should possess at least the following instruments: 1) Insulation Tester: 500V, 1000V, and 2500V- 1 No ea ch. 2) Earth Tester with accessories (0-10) Ohms- 1 No 3) Voltmeter 0-600V- 1 No 4) Tong Tester with Ammeter 300V- 1 No 5) Phase Sequence Indicator- 1 No 6) Crimpling tool with Dye set- 1 No 7) Suitable Rubber hand Gloves- 1 pair for each wor kman 8) Porta ble drilling machine- 1 No In addit ion to the above, the Contract or should have in his/its possession all the instruments and tools of B.I.S Standard in adequa te number for car rying out the execution, tests a nd inspections of all classes of wor ks authorized as specified by the Board. 4)Class-II Electrical Contractor shall be eligible to carr y out electrical wiring and installa tion works up to 650 Volts, subject to the class limits of the Certificate of the Electrical Supervisor employed. The scope of the works may be increased when the limit of the Certificate is increased by paying t he prescribed fees. A Class-II Contractor ’s L icense may be granted to a person who himself holds a valid certificate of Competency issued under these r egulations and actually works as a full time Supervisor in respect of the works underta ken by him and has at least one Workman, holding a valid Permit issued under these regulations, under his or its full time employment or to a person or a firm having a t least one Supervisor holding valid Certificate of Competency issued under these regulations and at least one workman each holding a valid P ermit issued under these regulations, under his or its full time employment provided such person or firm has in his or its possess ion all the instruments and tools of the B.I.S standard in adequate number for carrying out the test s and examination as required under the Rules. 5)The contractor should possess at least the following Instruments: 1)Insulation Tester: 500V- 1 No 2)Earth Tester with accessories (0-10) Ohms- 1 No 3)Voltmeter 0-600V- 1 NoEx-62/2017 5 4)Tong Tester with Ammeter, 300V- 1 No 5)Porta ble drilling machine- 1 No 6)Phase Sequence indicator- 1 No In a ddition to the above, the Contractor should have in his/its possession a ll the instruments and tools of BIS Standard in adequate number for carrying out the execution, tests and inspections of all classes of wor ks authorised as specified by the Board. 6)Special Class (Temporary): In addition to the above two general classes, there may be a Special Class (Temporary) Contractor ’s Licence which is non-renewable a nd shall be issued for a period of six months only under very special circumstances. Depending upon the limit of Supervisors and Workmen employed by the Contr actor a nd the availability and Capacity of the testing instruments in his possess ion, this class of Contractor shall be eligible to undertake all t ypes of works ca pable of being carried out by either Class-I or Cla ss-II C ontract ors. Provided that the Board may also grant Non-Renewable Certificate of competency for six months at a time to a Supervisor engaged by such firm or person on t he strength of the Certificate of competency issued by competent authority of any other St ate. 14.When Electrical Contractor’s License shall not be granted: An Electrical Contractor ’s Licence shall not be granted to a ny holder of a n Electrical Supervisor ’s Certificate or any holder of an Electrical Workman’s Permit while he is the employee of another Electrical Contractor. 15.Application for Electrical Contractor’s licence: Application for Electrica l Contr actor ’s licence shall be made to the Secretary in Form - A by pa ying the schedule of fees in Annexure -1. 16.Forms of Electrical Contractor’s Licence: An Electrica l Contra ctor ’s Licence shall be issued in Form - D 17.Cancellation of Electrical Contractor’s Licence. 1)If the Electrica l Supervisor /Workman, on the strength of whoman Electrical Contract or ’s Licence has been granted, leaves the service of such E lectrical Contractor, such C ontract or ’s Licence sha ll be deemed to have been su spended. If such Elect rical Contract or fails to employ an Electrical Supervisor/Electrical Workman within one month from the date on which the Electrical S upervisor and Electrical Workman had left such Electrical Contractor ’s service, such Electr ical Contractor ’s Licence shall be cancelled. 2)If a n Electrical Supervisor/Workma n to whom an Electr ical Contractor ’s licence has been granted accepts employment under a ny other Electr ical Contractor, the Contract or ’s Licence granted to such Electrica l Supervisor/Workman shall be automa tically cancelled. 3)The Board may, at any time cancel an Electrica l Contr actor ’s Licence if the person (or firm) to whom the Licence has been granted is in the opinion of the Board, not fit to hold the Licence. F or this purpose the Board may take into consideration, a mongst others, the provisions cont ained in Regulation 38. 18. Renewal of Electrical Contractor ’s Licence: 1)Every Electrica l Contr actor ’s Licence granted under these Regula tions shall be renewed annually. A licence which is not r enewed after expiry will become invalid from the date of expiry. Application for renewal in Form - J together with the Licence and Non-Refundable prescribed fees shall be submitted to the Secretary at least one month before the date of expiry of the Licence. Ex-62/20176 Provided that if t he application for renewal as aforesaid is r eceived within one month from the date of expiry of the Licence, it may be renewed on payment of the prescr ibed annu al renewal fee and prescribed fee for la te renewa l of the Licenc e. The date of next ex pir y will be twelve months from the date of last expiry. 2)Electrical Contract or ’s Licence, which is not renewed within one month from the date of expiry, will be automatica lly cancelled. Fresh initial fee with an application in Form - A must be furnished as in case of fresh application befor e a new Licence is granted. 3)The Licence shall automatically b ecome invalid after its expiry till renewal and no electr ical work shall be done by the Contractor while the Licence is inva lid. 19. Forms to be maintained: All Licensed Electr ical Contractor s are required to maintain the following Forms and s ubmit to the Secretary, Mizoram Electrical Licensing Board along with applications for renewal of their respective Licences. (a) Form - H details of Supervisor, Workman and Apprentices. (b) Form - I Yearly return of work done. 20. Register of Contractors: A register of all Electrical Contractor s Licence under these Regula tions shall be mainta ined by the Secr etary, Mizoram Electr ical Licensing Board and published from time to time. 21.Electrical Contractor to keep instruments in good condition: 1)All Electrical Contractors, to whom Licences have been granted, shall keep all the prescribed instruments in good condition. 2)The instruments in the possession of every Licensed Electrical Contra ctor ma y be inspected fr om time to time by the Secretary or his repr esentatives. 22. Notice of termination of service: If a n Electrical Supervisor/Workman in the employment of a Licensed Electrica l Contra ctor leaves his service, the termination of the service sha ll be notified in writing to the Secretary, both by the Electrical C ontract or and t he Electrical S upervisor/ Workman. 23. Work Execution: a)All electrical ins tallation works are to be car ried out by Electrica l Contr actor having valid licence under the direct supervision of the Electrical Supervisor holding va lid licence and by a Workman holding a valid permit issued by the Board. b)The contractor shall submit notice before commencement of work to the SDO (P&E) concerned, the Electrical Inspectorate in Form – K wherever a new work is taken up by him; provided notice for interna l wiring works upto 20kw load may be given to the SDO (P&E) concerned o nl y. c)No electrical installation work which has been carried out in contra vention of sub-regula tion (a) shall either be energized or connected to the works of any energy supplier. [Regulation 29 (2) Central Electricity Authority (Measures relating to Safety and Electric Supply) Regulation, 2010]. 24. Test Reports: 1)For all electrical installation works car ried out as per Regula tion 29 of The Central Electricity Authority (Measures relating to Safety and Electric Supply) Regulations, 2010, Test reports shall be submitted by the Licensed Electrical Contractor to the Electrical Energy Supplier/Ex-62/2017 7 Supplier of energy concerned in the form approved by Electrical Inspector under Regula tion 31 of The Central Electr icity Authorit y (Measures r elating to Safety and Elect ric Supply) Regulations, 2010. 2)After carrying out all the necess ary test s of all elect rical installation wor ks, the test report shall be filled up and signed by the Electrica l Supervisor under whose supervision the works have been ca rried out. All the test results should be sa tisfact ory and within permissible limits. The Test Report shall be counter signed by the Licensed Electrical Contractor. 3)The Licensed Electrical Contract or and Electrical Supervisor shall be jointly resp onsible for the due execution of all the electrical installation works and the materials used and the Electrical Supervisor shall be present at the time of testing by the Electrical Energy Supplier/Supplier of Energy concerned. 25. Examination: 1)Examination shall be held for Supervisor s and Workman b y the Board at such places and on such dates a s may b e notified by t he Secretary from time to time in loca l Newspa per. 2)Every examination shall be of such nature as to test the practical knowledge of the candidate and to ascertain his competency a nd the adequacy of his practical experience to the satisfaction of the Board for the purpose of gr anting Permits and Certificates under these Regulations. 3)Every examination shall be conducted in a pla ce where the ca ndidate’s knowledge can be practically tested and each candidate sha ll be tested with written and viva-voce. 4)The examina tions a nd test shall be held in English or in the officia l Language depending upon the choice of the candidate. 5)The Board s hall hold examinations normally twice a year on dates to be circulated by the Secr etary of the Board. 6)The fees pa id by a candida te, whose application for admission to an examination has been accepted, s hall not be refunded on any account. If the candidate fails to appear in examination, fees paid will be for feited. 26. Qualification: To appear in the exa mination, a candidate should be as under – 1)In r espect of Elec trical Supervisor ’s C ertific ate: Candidates for exa mination of Electrica l Supervisor ’s Certificate shall be person who- (i)have passed class X. (ii)are permanent residents of Mizor am and not below 18 year of age. (iii)have passed the examination for Electr ical Workman and have at least 5 year s practical experience, of which not less tha n two years should be a fter passing Wor kman’s Permit Examina tion 2)In r espect of Electrical Workma n’s Permit: Candidates for examination of Electrical Workman’s Permit shall be a person who - (i)have passed class VIII (ii)are permanent residents of Mizor am and not below 18 years of age (iii)have worked on wiring and electr ical installation work as an apprentice for at least two years under Licensed Electrical Contractor, or (iv)have passed other electrical training or practica l experience in electr ical installation works, which is regarded, satisfa ctory by the Board. 27. Full Marks: Full Marks would b e as under- Ex-62/20178 1)For Electrical Supervisor ’s Certificate: a. Written - 100 b. Viva Voce- 100 2)For Workman’s Permit: a. Written - 100 b. Viva Voce- 100 28. Pass Marks: Electrical Supervisor ’s Certificate and Electrical Wor kman’s permit will not be granted unless a candidate secures 50% of total marks each in written examination and viva voce. Candidates who are exempt ed from written examination also ha ve to secure a t least 50% marks in viva voce. 1)The Board may grant Electrical Supervisor ’s certificate in any class commensurate with practical knowledge and experience to a candida te who holds a Degree or diploma in Electr ical Engineering, Electrica l & Electronic Engineering, Electronic Engineering, Mechanical Engineering, Electronic a nd Communication Engineering and Electronic and Telecommunication Engineer ing without requiring him to sit for written examina tion, based on viva-voce, after paying the prescribed initial fee. 2)The Board ma y also grant Supervisor ’s Certificate for Cla ss–I – C lass–IV to a Degree Or Diploma candidates of retired Electrica l Engineers, Electrica l and Electronic Engineers, Mechanical Engineering, Electronic Engineers, Electronic and Communication Engineers and Electr onic and Telecommunica tion Engineers of P &E Depar tment, Mizoram aft er passing viva -voce examination and after paying initial fee. 29. Examination for Electrical Supervisor’s Certificate: 1)A ca ndidate for Electrical Supervisor ’s Certificate examination must apply to the S ecretar y in prescribed form (Form-B) with the following docu ments and pay the examination fee: i) Attested copy of Voter ’s ID. ii) Certificate from Contractor in Form ‘G’ - appended to these R egulations. iii) Electrical Workman’s Permit, if any. iv) Certificate of technical qua lifications (attested copy) v) Two copies of recent passport size photographs, all of which shall bear the applicant’s name on the back. 2)Candidate for examination of Electrical Supervisor ’s Certifica te shall be examined by a written paper and by Oral t ests. Candidate will normally be examined thr ough the medium of English language but the Board may permit a candidate to be exa mined through any other medium as may be possible for the Board to arra nge. 3)The syllabus of the several parts of the examinations is set out in Annexur e - II. Candidates may appear in examinations for any class. The class to be passed to qualify for different Classes of Certificates are as below: 4)For the purpose of these Regulations all Electrical installation works shall be divided in cla sses as shown below: ClassesCertificate for Part compulsory Class-IWiring for system not exceeding 650 Volts- 1,2,3,4 Class-IIOverhead lines and installationsnot exceeding 33,000volts- 1,4,5,6,7,9 Class - III Underground Cable not exceeding 33,000volts- 1,7,8 Class-IVOverhead lines and installations exceeding 33,000 volts - 1,4,5,6,7,9,10Ex-62/2017 9 30.Grant of Electrical Supervisor’s Certificate: 1)Every candidate who passed the examinations for Electrical Supervisor will be granted a certificate for the installation works of differ ent cla sses which he passed a s set ou t in Form - E, a fter pa ying the prescr ibed initial fee within one (1) year from the date of declaration of examination result. 2)The Board ma y also grant Electrica l Supervisor ’s certificate in any class commensurate with practical knowledge and experience to a candida te who holds a Degree or diploma in Electr ical Engineering, Electrica l & Electronic Engineering, Electronic Engineering, Mechanical Engineering, Electronic a nd Communication Engineering and Electronic and Telecommunication Engineer ing without requiring him to sit for written examina tion, based on viva-voce, after paying the prescribed initial fee. 3)The Board may also grant S upervisor ’s Certifica te for Class-I – Class–IV to a Degree or Diploma candidates of retired Electrical Engineers, Electrical and Electronic Engineers, Mechanical Engineering, Electronic Engineers, Electronic and Communication Engineers and Electr onic and Telecommunica tion Engineers of P &E Depar tment, Mizoram aft er passing viva – voce examina tion and after paying initial fee. 31. Renewal of Electrical Supervisor’s Certificate: 1)Ever y Electr ical S u pervisor ’s Cert ificate gr anted under these Regula tions sha ll be renewed ever y year or three years a t a time after paying prescribed fees shown in Annexure - I. Any Certificate, which is not r enewed after expiry will become invalid from the date of exp iry. Application for renewal in Form - L together with the Supervisor ’s Certificate and non- refundable prescribed fees shall be submitted to the Secretary within one month before the date of exp iry of the Certificates. Provided tha t if the application for renewal as a foresaid is received within twelve- months from the date of expiry of the Certificate, it may be renewed on p ayment of the prescrib ed r enewal fee and pres cribed fee for la te renewa l of the Certific ate. The date of renewal after expiry will be the date on which the Certificate is renewed. The date of next expiry will be one year or three years or from the date of last expiry. 2)Electrical S upervisor Certificate, which has not been renewed within twelve months from the date of expiry, will be automatically cancelled and fresh initial fee with an applica tion in Form - B must be fu rnished as in case of fresh application before a new Supervisor ’s certificate will be granted. 3)The Board may, at any time cancel an Electrical Supervisor ’s certificate if the per son to whom the Certificate has been gr anted is in the opinion of the Board, not fit to hold such Certificate. For this purpose the Board may take into consideration, amongst other, the Provisions contained in Regulation 31. 32. Examination for Electrical Workman’s Permit: 1)A ca ndidate for exa mination of Electrical Workma n’s Permit must apply to the Secretar y in prescribed form For m - C with the following documents and pay the examination fee: i)Attested copy of Voter ’s ID. ii)Certificate from Contract or in F orm - G appended to these Regulations. iii)Electrical Workman’s Permit, if any. iv)Certificate of technical qua lifications (attested copy) v)Two copies of recent passport size photographs, all of which s hall bear the a pplicant’s name on the back. 2)Candidate for examinations of Electrical Workman’s Permit shall be examined by a written paper and by Oral t ests. Candidate will normally be examined thr ough the medium of English language but the Board may permit a candidate to be exa mined through any other medium as may be possible for the Board to arra nge. Ex-62/201710 3)The syllabus of the severa l parts of the examinations is set out in Annexure - III. Candidates may appear in examinations for any class. The class to be passed to qualify for different Classes of Permit are as below: 4)For the purpose of these Regulations all Electrical installation works shall be divided in cla sses as shown below: ClassesCertificate forPart compulsory Class-I:Wir ing for system not exceeding 650 Volts- 1,2,3,4 Class-II:Overhead lines & installations not exceeding 33,000volts- 1,4,5,6,7,9 Class - III :Underground Cable not exceeding 33,000volts- 1,7,8 Class-IV:Overhead lines & installations exceeding 33,000 volts- 1,4,5,6,7,9,10 33. Grant of Electrical Workman’s Permit: 1)Every candidate who passed the examinations for electrical Workman shall be granted a Permit for the installation works of different classes which he passed as set out in For m - F a fter paying the prescribed initial fee within one (1 ) year from the date of declaration of result. 2)The Board may also grant a Permit to any candidate who ha s passed I.T.I from any recognized institute in the trade of Electrician, Wireman, Mechanic Refrigerator and A/C, Mechanic Radio and Television, Electronic Mechanic, Information Technology and Electr onic System Maintenance whose qualification and pra ctical experience are such a s to justify the grant of Workman permit of the appropriate class after passing Viva-Voce, without written examination, after paying the prescribed initial fee” 34. Renewal of Electrical Workman’s Permit: 1)Every Electr ical Workman’s Permit granted under these Regulations shall be renewed every year or three years at a time after paying prescribed fees shown in Annexure -I. Any Permit, which is not renewed after expiry will, become invalid fr om the date of expiry. Applica tion for renewal in Form - L together with the Workma n’s Permit and non- refundable prescr ibed fees shall be submitted to the Secretary within one month before the da te of expiry of the Permit. Provided tha t if the application for renewal as a foresaid is received within twelve- months from the date of expiry of the Permit , it may be renewed on payment of the prescribed renewal fee and prescribed fee for la te r enewa l of the Permit . The dat e of r enewa l a fter ex pir y will be the date on which the Permit is renewed. T he date of next expiry will be one year or three years from the date of la st exp iry. 2)Electrical Workman‘s Permit, which has not been renewed within twelve months from the date of expiry, will be automatically cancelled and fresh initial fee with an applica tion in Form - C must be fu rnished as in case of fresh a pplication before a new Workman’s Permit will be granted. 3)The Board ma y, at a ny time cancel an Electrical Workman’s Permit if the person to whom the Permit has been gra nted is in the opinion of the Board, not fit to hold such Permit. For this purpose the Board may take into considera tion, a mongst other, the Provisions contained in Regulation 31. 35. Grant of Duplicate Licence, Certificate or Permit: On being sa tisfied that an original Licence, Certificate or Permit gr anted under these regulations has been lost or destroyed, the Secretary may, on request in writing by the application, grant a duplicate. A duplicate of Licence, Certifica te or Permit gr anted under these Regulations shall be issued on payment of the pres cribed fee.Ex-62/2017 11 36. Restriction of employment for Electrical Supervisors and Electrical Workmen: 1)A person holding Electrical Supervisor ’s Certificate should not be an employee of more than two different Elect rical Licensed Contract ors within the same period. 2)A person holding E lectrica l Workman’s Permit should not be an employee of more than one Electrical Licensed Contractor within the same period 3)An Electrical Supervisor/Workman employed by a Licensed Electr ical Contractor should not be a regular/Work charged/officiating/contract/muster roll employee of a Central or State Government or a Government undertaking or a regular/full time employee of any other Compa ny or Firm or Agency. 4)A person holding both Supervisor ’s Certificate a nd Contractor ’s Licence should not be an employee of a ny other Contractor. 37. Report of negligence: 1)When a situation a rises in which a Licensee or a person for whom any elect rical installa tion work is being or has been carried out by an Electrical Contractor licensed under these Regulations, is, in the opinion of the licensee or a person, not in conformity with the Central Electricity Authority (Measures relating to safety and Electric Supply) Regulations, 2010 and Licensee or person desires to bring the facts to the notice of the Board, he shall make a report in writing to the Secretary. 2)A report ma de to t he Secretary under these regulations by a person other tha n a Licensee shall be accompanied by a deposit of Rs. 500.00 or such larger amount as the Board may fix by special order in any case. If in the opinion of the Boa rd, the charge contained in the repor t is not substantiated, the Board may direct that the deposit shall be forfeited, if the report is substantiated, the deposit shall be retur ned. 3)If electrical insta llation work has been being or has been car ried out by Electrical Contra ctor licensed under these regulations is actually not in conformity with the Central Electricity Authority (measures relating to Safety and Electric Supply) Regulation, 2010, the Board may take action as deemed fit, which may enta il imposition of cancellation or suspension of licence. Decision of the Board will be final. 4)If any person holding an Electrical Wor kma n’s Permit or a Supervisor ’s cer tifica te or an Electr ical Contractor ’s L icence is found by the Boar d to be guilty of negligence, misrepresentation or delibera te suppr ession of facts, incompetence or breach of these Regulations or of t he conditions of his P ermit, Certificate or Licence. The Board may take action as deemed fit which may entail suspension or cancella tion of licence. The decision of the Board in these regar ds shall be final. 5)If a ny mutilation or defacement of, or any unauthorized entry in any E lectrica l Workman’s Permit or Electrical Supervisor ’s Certificate or Electrical Contract or ’s Licence is found the Boar d may take act ion as deemed fit which may entail cancellation. The Board’s decision will be final. 38. Electrical Licensee to obtain Contractor ’s Licence: No electrica l installation work shall be ca rried out by a person licensed under P art - IV of the Electricity Act 2003 or an Electricity Board or a State Government Depa rtment responsible for the distribution of energy, in a premises beyond the point of commencement of supply unless he has obta ined an Electrical Contractor ’s Licence and employs staff of Electrical Supervisors and Electr ical Workman in conformity with these R egulations. 39. Cancellation of Contractor’s Licence granted to Electrical Licensee: An Electrical Contr actor ’s Licence granted under Part - IV of the Electricity Act, 2003 shall be liable to be withdr awn or cancelled if in the opinion of the Board pr eferential treatment r esulting in unfa ir competition with local contractors is given to prospective consumers. Ex-62/201712 40. Amendment of Annexure: Schedule of fees contained in Annexure-I, Syllabus for Electrical Supervisor ’s Certificate Examinations contain in Annexure-II, Syllabus for Electrical Workman’s Permit Examinations contain in Annexure-III and Forms contained in Annexure-IV and remuneration for examiners etc may be amended by the Board from time to time. 41. General Provisions for Appeals: 1)An appeal against a n order made under these regulations shall lie to the State Government. 2)Every appeal made under sub-regulation (1) shall be in writing accompanied by a cop y of the order appealed against and shall be presented within 3 months of the date on which such order ha d been made. 42. Remuneration for Examiners and invigilators: An Examiner shall r eceive the remuneration as pr escribed by the Sta te Government from time to time. 43. Mode of Contract:- 1)Every Elect rical installation work under taken by a Contractor shall be recor ded in writing and the Contractor shall be held responsible for the workma nship and qualit y of all materia ls supplied by him and used in the wor k for the proper execution of the Contractor. All the installation work shall be recor ded as per Form - I as prescr ibed in the schedule of Form and shall be opened for Inspection. 2)No Electrical installation works including additions, alteration repair and adjustments to existing installation, excepting such replacement of lamps, fans, fuses, switches and other components/ parts of the installations which, in no way alteration of its capacity or character, shall be commenced by a Contractor without notifying the Secretary and the Electrica l Inspector ha ving jurisdiction and the concerned Electrical supply authorit y in Form - K a s prescribed in the form. Provided that notice for int ernal wiring works upto 20kW load may be given to the SDO (P&E) concerned only. Before the commencement of the actual work, the Contractor shall obtain the approved copies of the electrical drawings (approved by the concerned Electric Supply Authority) from the occupier or owner or of Supplier of the works. T he works shall be car ried out in accor dance with the approved drawing of the insta llation or the work complying with relevant provisions of the Regulations and the recommendations of the Indian Standard Code of practice. 3)For every Electrical Installation work carried out under regulation 29 of Central Electricity Authority (Measures relating to Safety and Electric S upply) Regulations, 2 010, a Test – Report with relevant dra wing shall be submitted by the Contra ctor to the concerned Electric Supply Author ity. The test shall be carried out in the presence of the Supervisor and the Test- Report shall be signed by the Supervisor under whose supervision the work had been carried out and shall be countersigned by the Contractor. T he Supervisor shall be wholly responsible for the correct execution of the electr ical installation work as per the relevant pr ovision of the Regula tions a nd the recommendation made from time to time by the Indian Standard Instit utes. In addit ion, the Contra ctor shall fur nish a copy of the Test-Report to the electric supply authority as well as to the Electrical Inspector having jurisdiction. Provided tha t notice for internal wiring works upto 20kW load may be given to the SDO (P&E) concerned only.Ex-62/2017 13 44. Change of name(Firm/Body): 1)Any firm or body holding a Contractor ’s License of any class may make an application to the Secr etary along with the fee prescribed in the Schedule of fees appearing in Annexure- I for effecting a ny change in the name of the firm or body and the Secreta ry may, with t he appr oval of t he Chairman, a llow such change provided it does not involve any transfer of assignment of the License to any other person, firm or body. 2)Where any change is a llowed under the pr oceeding Sub - R egulation, the Secreta ry sha ll make endorsement to this effect under his hand and sea l with date in the License as well a s in the r ecords of the Board. 45. Suspension, Revocation of certificate/Licence: The Board ma y direct the su spension or revocation of a certifica te/Licence/Permit, if the Boar d is satisfied that the holder:- a) has committed a breach of a ny of these conditions or : b) has committed a breach of any conditions stated in the Certificate/Licence/Permit as the case may be; or c) has failed to furnish any information or record to the Electrical Inspector which he has required for the purpose of satisfying himself whether any provision of the aforesaid condit ions ha s been complied with or whether any order of the Electrical Inspector has been car ried out or d) has been guilty of such mis-conduct as t o render the suspension or revocation of the certificate/license/permit is justified and desirable in public interest or: e) has shown inefficiency or negligence in the execution of electr ical works. 46. Board Decision to be final: The decision of the Board in all matters relating to the examination of candidates for grant of Permit, Certificate of competency and to issue renewal, suspension and revocation of Permit/Certificate of competency/ Electrical Contractor ’s Licence, imposition of penalty, etc. shall be final. 47. Matter not specified in the Regulation: The Board may cons ider and make suitable decision in matters which are not clearly specified in the Regu la tion. 48.Repeal and Saving: On a nd from the commencement of these regulations, T he Mizoram Electr ical Licensing Regulations 2003 published in the Mizoram Gazette Extra Ordinary Issue No. 243, dt 1.9.2003 under Notification No. B.16012/24/2000-P&E, dt.27.8.2003 (As amended in 2010) shall stand repealed. Provided that any order made or anything done or any action taken under the Regulations so repealed shall deemed to have been done or taken under the corresponding provisions or these r egulations. 49. Accounts : 1.The financial year of the accounts shall be from 1st Apr il to the following 31st Ma rch. 2.The Board shall, in respect of the Licensed Contractor/Supervisor/Workman, keep such acou nting records a s would be required so that the revenue cost, assets, liabilities, reserve and the provisions for, or resonably attributa ble to the Licensed Contractor /Supervisor/Wor kman are separately identifiable in the book of the Electr ical Licensing Board, and 3.The Board shall, upon the request by any person/authorized body, make available a cop y of each accounting statement a t a price not exceeding its photo copying charges. Secr etary to the Government of Mizoram, Power & Electricity Department, Aizawl, Mizoram. Ex-62/201714 ANNEXURE-I SCHEDULE 0F FEES(See regulation 15) 1. Fees for Electrical Contractor’s License: Class ofInitialRenewalLateDuplicateIncrease ofChangeContractorfeefeerenewalLicense feescopeoffee perfeenamemonthClass-IRs 4,000Rs. 1,500Rs. 500Rs. 1,000-Rs. 1,500 Class-IIRs 3,000Rs 1,000Rs. 500Rs 1,000Rs.1,000Rs.1,500 2. Special Class (Temporary) Electrical Contractor ’s License: Class of WorkInitial FeeDuplicate License feeUp to 650 VRs. 5,0002,000 Above 650 v & up to 33KVRs.10,0002,000 Above 33 KV Rs.15,0002,000 3.Fees for Electrical Supervisor’s Certificate ( S ee Regulation 29,30 & 31): Initial feeExaminatio n feeRenewal feeLate renewalDuplicatemonthfor each class per year fee perCertificate feeRs.500Rs.150Rs.200Rs.100Rs.300 4.Fees for Electrical Workman’s Permit (See regulation 32, 33 & 34): InitialExaminationRenewal feeLate renewalDuplicatefeefee for eachclassper yearfee permonth Permit feeRs.350Rs.100Rs.150Rs.100Rs.250 Notes:- 1.An Electrical Contractor holding a valid License granted under these Regulations and desires to increase the scope of his wor k shall submit a fresh application in Form - A 2.Should a passed candidate desires to qualify, subsequently for a class other tha n that for whic h a cer t ifica t e or p er mit ha s b een gr a nt ed, h e will b e p er mit t ed t o a p p ea r in t he ex a mina t ion for the parts concerned. S imilarly, those who apply for exemption from examina tion and who have been granted a Permit/ Certificate for one class or more classes may apply with the requisite fee for examina tion in any other additional class or Classes. 3.All Fees levied under these Regulations shall be paid to the Secretary. 4.Printed copies of these regulations may be obtained from the Secretary, on payment of the cost. 5.Forms of applications may be obtained from the Secretary, Mizoram Electrical Licensing Boa rd.Ex-62/2017 15 ANNEXURE-II [See regulation 29 (3)] SYLLABUS FOR ELECTRICAL SUPERVISOR’S CERTIFICATES EXAMINATIONS Part-1 ELEMENTARY PRINCIPLES1.Principles of Electricity: Electric pr essure, current and r esistance, Ohm’s Law, Kirchhoff ’s La w, calculation of voltage drop, series and parallel circuits, unit of voltage, current, resistance, power and energy, relation between electrical unit (kW) and mechanical power unit (HP), inductance, capacitance, reactance and impeda nce. 2.Electromagnetism: Flux, flux density, magnetic field strength, permeability, magnetic circuits; reluctance, calcula tion of MMF, effect of air gap, hysteresis loop of magnetic materials, Electroma gnetic Inducta nce, production of EMF, Fleming’s Hand Rules, Faraday’s Laws, Lenz’s Law, Self and Mutual Inductance, Coupling coefficient, magnetic properties of materials, Electro-magnets and their applications. 3.Materials: Conductors, non-conductor s, insulators, insulating materia ls a nd their utilit ies, tr ansformer oil, effect of heat and moistur e on insulation, dielectric, permittivity, different types of wir es, cables, switches, circuits breakers, fuses. 4.Generation of Electricity: Method of genera tion of electric power, block s chematic layout of generating station; Hydro - electric, T hermal and Nuclear sta tion. Non-conventional Energy sources, solar power, wind power. 5.Acts and Regulatio ns: Wor king knowledge of: 1)The Electricity Act, 2003. 2)The Central Electricity Authority (Measures relating to Safety and Electric Supply) Regulations, 2010. 3)The Mizoram Electr ical Licensing Regulations, 2 017. 4)The relevant Joint Electr icity Regulatory Commission for Manipur & Mizoram Regulations such as: i)Electricity Supply Codeii) Consumers Grievances Redressal Regula t ions iii)Prevailing Power Tar iff. Part-2 WIRING FOR SYSTEM NOT EXCEEDING 250 VOLTS1.Do mestic Installation: Various types of LT wiring - cleat, casing and capping, metal sheathed, condu it, types of wires, cables and their standard sizes with current carrying capacities, estimates of materials and cost of different types of installations, load survey, connected load, maximum demand, main switch board, distribution board, location of switch board, distribution layout a nd circuit dia gram, s election of fuses, M.C.C.B.(Moulded Case Circuit Breaker) Ex-62/201716 2.Illumination: Char acteristics of different types of lamps, inca ndescent lamps, fluorescent lamps, vapors la mps, HPSV (High Pressure Sodium Vapour), LPSV (Low Pressure Sodium Vapour), LED (Light Emitting Doide), magnetic induction lamp, energy efficient lamps, photometric unit and their measurement. 3.Earthing : Resistivity of soil and their measurement, computation of ear th resistance, differ ent materials used for earthing conductors, corrosion fact or, determination of size of earth bus, pla te, pipe and s trip earthing. 4.Installation testing and measurement: Insu la tion tester, earth t ester, ammeter, voltmeter, wattmeter, ener gy meter with M DI (Max imum Dema nd Indicator) facility, recommended va lue of insulation resistance, earth r esistance, pola rity test, continuity test, insulation test, earth resistance test, detection and location of faults. Part-3 WIRING FOR SYSTEM NOT EXCEEDING 650 VOLTS1.A.C. Circuits : Alternating current fundamentals, gener ation of alt ernating cu rrent, different wave forms, frequency, time period, average value, rms value and form factor, phasor representation of alternating quantities, rectangular, polar and exponential forms, analysis of simple AC circuits with resistance, induct ance and capacitance, concept of impedance a nd admittance, phasor representation, power and power fact or in AC circuits, active and reactive component, solution of R-L (Resistance-Indu ctance), R-C (Resistance-Capacitance), and R-L-C (Resistance-Inductance-Capacitance) circuits, series, parallel and series-parallel circuits. 2.Three phase system : Star and Delta connection, relationship between p hase and line value of voltage and current, phase repr esentation, solution of bala nce and un-bala nce thr ee phase circu its. 3.Symbols: List of symbols, preparation of electrical wiring diagram and electr ical cir cuit diagrams, reading of electrical diagrams. 4.Special types of equipments: X-Ra y, Neon-sign, lift, escalators, cinema installation, relevant rules, cir cuitry, safety precaution, earthing, fire precautiona ry measures for the above inst allation. IS 4878/91-C ode of practice for cinema installation. Part-4 AC& DC APPARATUS NOT EXCEEDING 650 V1.AC Generators (Alternators) : Basic principles, detail construction a nd essential component, volta ge regulation, method of voltage control a nd frequency contr ol, synchronizing of alternators, syncroscope, bright lamp and dark lamp method, associated switch board and its a ccessor ies.Ex-62/2017 17 2.DC Generators: Basic principles, detail construction and essentia l component, shunt, series and compound generators and their cha racteristics, commuta tors and their maintenance, car bon brushes-their adjustments and care, voltage regulation, par allel operation, associated switch board and its a ccessor ies. 3.Batteries: Primary cell, dry cell, Lead acid and Nickel-Cadmium batteries, construction, characteristic, charging and discharging. Charging circuits and their calculation, series and parallel circuits. Specifications, maintenance, storage of batteries, use of hydrometers, battery charging equipment and their operation. 4.AC Motors: Three phase induct ion motors, construct ion principle of opera tion speed, fr equency, slip, star-delta star ting. Single phase induction motors, construction, different method of star ting. Squirrel cage induction motors, slip ring induct ion motors. Synchronous motor s, gener al principle of operation, uses, insta llation method of star ting and speed control and reversal of direction, commuta tor motors. 5.DC Motors : Motor principle, series, shunt and compound wound type motor, their uses, installation, method of star ting, speed control, reversal of direction. 6.Control Gears: Various type of switches, fuses, starters, contr ollers, regulators-their uses and installation. Earthing of motors and generators. 7.Conversion: Principle of opera tion of motors and generators. Rotar y or Synchronous converters. Mercury-Arc rectifiers, inverters. Thyr istors and other static devices. Filtering-Half wave, Full Wave, Br idge rectifier. Part-5 OVERHEAD LINES NOT EXCEEDING 650 VOLTS1.Cons tructio n of lines: Construction of low and medium voltage lines, size of conductor, length of span, sags, strength of poles, different types of poles. S pacing of conductor s, cross arms, effect of tempera ture, wind pressure, ice and snow. Tension of wire, insulators, bracket, stays, struts, guard wires, protective device. Ear thing, lightning arrestors and lightning conductors and their test ing. 2.Operation: Test ing and fault location, methods of working on overhead lines, inspection of distribution lines. Three wires and four wires system. Power in three phase system. Phase sequence. Measurement of active and reactive power in single phase and three phase sys tem. 3.Clearances: Statutory clearances of live parts from ground and building. Sectional clearances, equipment clea rances. Cleara nce of switch board, oil containing equipment, indoor and outdoor equip ment clea ra nc es . Ex-62/201718 Part-6 OVERHEAD LINES NOT EXCEEDING 33,000 VOLTS1.Cons tructio n of lines: Construction of high volta ge lines. Sizes of conductor with cur rent ca rrying capacity. Length of span, sags, strength of the poles, differ ent type of poles. Design of different type of tower and their constr uction, erection and str inging of conduct or . Spacing of conduct or, cr oss arm, effects of temperature, wind pressure, ice and snow. Tension of wires, insulators, vibration dampers, brackets, stays, struts, guar d wires, protective devices. Earthing, lightning a rrestor and lightning conduct ors, and their testing. 2.Clearance: Statutory clearance of the live pa rts from ground and bu ildings . Sectional clearance, equipments, oil containing equipments. Indoor and outdoor equipment cleara nce. 3Operation: Methods of working on over head lines. Equipments used for r eplacement of insulators, their rating, method of r eplacement of insulators. Inspection of Tra nsmission lines. Line consta nts, determina tion of voltage drop. Voltage regulations. Effect of power factors and their improvement. 4.Transmission: Bulk Transmission of electric power. Typical power transmission scheme. Need for high transmission volt age. Pr imary and secondary tr ansmission systems. Part-7 UNDERGROUND CABLES FOR VOLTAGE UP TO 650 VOLTSBasic knowledge of different types of cables- PVC (Poly Vinyl Chloride), APVC. Genera l pract ical knowledge of laying cables; direct in ground, in troughs and in pipes, handling, bending, jointing, plumbing. Underground and above ground junction boxes. Distr ibution boxes and pillars. Joint box compounds, melting of compounds, fillings boxes with compounds. Part-8 UNDERGROUND CABLES FOR VOLTAGE UP TO 33,000 VOLTSBasic knowledge of different type of cables-AYFY, XLPE (Cross linked Poly Ethylene), oil filled, gas filled and any other t ypes. Testing and fault location, Murray Va rley loop test s. Current ratings- shor t time ratings and continuous rating. Dera ting factors of cables. Calculation of voltage drop. Alluminium and copper cable jointing- types, precaution, termination. I.S. Regulations regar ding cables. Part-9 INSTALLATIONS NOT EXCEEDING 33,000 VOLTS1.Switch Gear and Protection: Knowledge of various type of switches, protective fuses. Circuit breakers- OCB (Oil Circuit Breaker), VCB (Vacuum Circuit Breaker), ACB (Air Circuit Breaker), MCCB (Moulded Case Circuit Breaker), SF 6 (Sulphur Hexa F louride) Breakers, thermal and magnetic release Relays,Ex-62/2017 19 Buchholtz Relays, IDMT (Inverse Definite Minimum Time Relay), Instantaneous type. Over current, eart h fault and ea rth lea ka ge relays, t ime and current setting. HRC fuses, paper b arrel a nd HV fuse- use and construction. Lightning arresters, isolators Bus bar, D.O. (Drop-Out)cum Gang Switch, hook sticks. Earthing of S ub-Stations. 2.Transformers: Tra nsformer s – construction, use a nd maintena nce. Voltage and cu r rent r elations. Losses andefficiency. Par allel operation of three pha se transformers. Three phase transformer connections- Star/Star, Delta/Delta, Star/Delta, Delta/Star. Auto transformers, transformer tappings. 3.Instrument Transformers: Curr ent transformers (CT); specifications and err or fact ors. Potential transformers (P Ts). 4.Selection of Equipments: Different types of breakers- OCB, VCB, ACB, MCCB, MCB, SF 6 Breakers. Contactors, Breaking capa city, Ma king Ca pacity, Selection of Br eakers. Select ion of switches; Short time and continuous ratings. Power Factor cor rection by ca pacitor s. Shunt React ors. 5.Connections: Method of connection of special t ype Transformers, Rectifier tr ansformers. Welding tr ansformers. Determination of capacity, load segregation, Double bus system. Change over arrangements. Preparation of schematic diagra m of Sub- Station. 6.Energy Measurements: Measurement of power, Watt meters, Energy meters, Trivect or meters. Computation of Energy. 7.Clearances: Statutory clearances of live parts from ground. Sectional clearances, equipment clearances. Clearances of oil containing equipments. Part – 10 VOLTAGE RANGE: EXCEEDING 33,000VOLTSType of installation : Overhead lines and installations a voltages exceeding high pressure 33,000 volts. 1.General : Knowledge of conductors, supports, cross a rms, insulator s and other lines accessories used in H.T. Line constr uctions, application a nd uses, making bills of materials, basic knowledge of common types of ra ting of transformers used in power supply system- types, r ating, used of common Sub- Sta tion equipment such as cir cuit breakers, distr ibution pillars, lightning arrestors, bushing for transformers and other equipment, CTs and PTs. 2.Cons truction : Methods of construction of overhead line exceeding 33,000 volt s; conductor, jointing, jumpering and knowledge of configuration of conductors, clearances, sag, spans etc. insta llation of pole and floor mounted transformers and associated sub-sta tion equipment, installation of circu it breakers, isolators, gang operated switches and fuses, etc. Ex-62/201720 3.Service connection at high Voltage: Use and installation of CTs & PTs for High Pressure Metering. 4.Testing : Methods of t esting overhead lines and sub–station equipments, fault testing, location a nd rectification. 5.Earthing: Knowledge of practices and procedures of earthing for H.T. (High Tension) Overhead line equipment and sub-stations. 6.Working procedures : Line cleara nce procedures – safe working practices for High Voltage overhead line installations, intimate knowledge of electrical shock treatment methods and procedures. 7.Maintenance : Methods of maintenance of overhead lines, sub-sta tions, sub-sta tion equipment, transformers - oil test ing and filtration. 8.Regulations and codes of practice: Familiarity with the relevant Central Electricity Authority (Measures relating to Safety and Electric Supply) Regulations,2010 a nd National Codes of practice, R.E.C. standa rds and Codes of pract ice. ANNXURE-III [see regulation 32 (3)] SYLLABUS FOR ELECTRICAL WORKMAN’S PERMIT EXAMINATIONS Part-1 ELEMENTARY PRINCIPLES1.Principles of Electricity: Concept of voltage, current, resistance, inductance, capacitance, reactance, power, energy and power fact or. Comparison between series and para llel connection of loa ds. Simple calculation of curr ent, power energy and voltage drop. Units of voltage, current, resistance, power and energy. 2.Materials: Properties of conductors, non- conductors and insulators. Properties of copper and aluminum conductor. Insulating materials a nd their utilit ies such as PVC, rubber and porcelain. Different types of wires, ca bles, s witches , cir cu it brea ker, fu ses. 3.Drawing and Circuits: Reading of schematic diagram for internal wirings and control circu its. St andard symbols of var ious types of electrical equipments. Wir eman tools and accessor ies. 4.Safety measures: Safety measures to be observed while working on live parts. Devices used for wirema n’s safety. Action to be taken in case of electrical accidents. 5.Rules and standards: Knowledge of prevailing power tariff. Procedure for availing electric supply to consumers. Submission of test reports/Completion reports.Ex-62/2017 21 Part-2 WIRING FOR SYSTEM NOT EXCEEDING 250 VOLTS1.Domestic installations: Various types of wiring – cleat, casing and ca pping, metal sheathed, conduit. Types of wires, ca bles and their standard sizes with curr ent carr ying ca pacities. Main switch board, distribution boa rds, loca tion and clear ance of switchboards. Distribution layout and cir cuit diagram. Different types of fittings, a nd switches; use of test lamp. Connection and diagra m of distribution boar ds, ceiling rose, plugs and sockets, lamp holders- incandescent and fluorescent la mps, fa ns with regulators, two way switches. 2.Protection: Overload protection, earth leakage protection, permissible load, select ion of fuses-r ewirable and HRC (High Rupturing Capacity) types. Circuit Breakers, M.C.C.B. 3.Illumination: Characteristics of different types of lamps. Incandescent lamps, fluorescent lamps, compact fluorescent lamps (CFL), LED. 4.Earthing: Earthing of systems. Necessity of earthing .Types of ear thing. Selection and location of earthing .Types of size of earthing conductor. 5.Installation testing and measurements: Insulation tester, Earth tester, energy meter with MDI. Recommended values of insulation resistance, earth resistance. Polarity test, Continuity test, Insulation test, Earth resistance test. Part-3 WIRING FOR SYSTEM NOT EXCEEDING 650 VOLTS1.Three phase system: Relationship between phase and line values of voltage a nd current. Wir ing of three phase sys tem. Star and delta connection. Selection and identification of different cables and conductor. Protective system used in internal wiring. Use of b ell and battery for sorting out in circuits. Method of testing pola rity and phasing out circu its. 2.Jointing and soldering: Making straight and T joints in solid and stranded conductors a nd soldering them. Soldering p lugs and sockets, wires and ca bles and insulating t hem. 3.Symbols: List of symbols. Prepara tion of simple electr ical wiring diagrams and electrical circuit diagr ams. Reading of s imple electrica l circuit diagr ams. 4.Tariffs: Knowledge of prevailing power tar iff. 5.Special type of equipments: X-Ra y, Neon- sign, lift, Escalators,Cinema insta llations: Circuitry, Safety Pr ecaution, Earthing, Fire Precaution measure for the above installa tion. Wiring of specia l equipment like UPS, Inverters, Stand by for computers, etc. Essential factor for wiring High Rise Building. Ex-62/201722 Part-4 AC& DC APPARATUS NOT EXCEEDING 650V1.AC&DC Generations: Basic principle, construction and components. Commutators and their maintenance. Carbon brushes- their adjustments and care. 2.Batteries: Primary cell, Dry cell, lead a cid a nd Nickel – Ca dmium batteries; constr uctions, charging and discharging. Maintenance of storage of batteries. Use of hydrometers. 3.AC Motors: Three phase induction motors, construction, principle of operation. St arters- Direct on line and star- Delta starting. Single pha se induction motors-construct ion. Different types of fan regulators- resistant and electronic types. Pr inciple of opera tion of fra ctional Horse Power motors used in appliances, such as mixers, washing machines, etc. 4.DC Motors: Motor principle, their uses, installations, methods of starting, reversal of direction. Part-5 OVERHEAD LINES NOT EXCEEDING 650 VOLTS1.Cons tructio n of lines: Construction of low and medium voltage lines, use of safety and protective devices. Size of conductor, length of span, sa gs. Different types of poles, pole concreting and erection. Spacing of conduct ors, fixing of cross ar ms. Jointing a nd binding of conduct ors. Fitting of different types of insulators, brackets, stays, struts, guard wires. Earthing of over head lines, fitting of light ning ar restors and lightning conductors and their importa nce, service connections. 2.Operation: Methods of working on over head lines. Ins pection of dis tribution lines. Three wire and four wire systems. 3.Clearances: Statutory clearances of live parts from ground and buildings. Sectional clearances, equipment clearances. Clearance of switch boa rds. Part-6 OVERHEAD LINES NOT EXCEEDING 33,000 VOLTS1.Construction of Lines : Construction of high voltage lines. Use of safety and protective devices. S izes of conductor, length of span, sa gs. Different types of poles, strength of poles, pole concreting and er ection. Spacing of conductors, tension of wir e, fitting of cross a rms, fitting of insulators, vibration damper brackets, fitting of s tays, struts, guard wires. Ea rthing, fitting of lightning arrestor s and lightning conductors and their testing. 2.Clearances : Statutory clearances of live parts from ground and buildings. Sectional clearances, equipment clea rances. Cleara nce of oil containing equipments.Ex-62/2017 23 3.Operation: Methods of working on overhead lines. Equipment u sed for replacement of insulators, their ratings. Methods of replacement of insulators. 4.Transmission: Bulk transmission of electric power. Typical power tr ansmission scheme. Need for high transmission volta ge. Part-7 UNDERGROUND CABLES FOR VOLTAGE UP TO 650 VOLTSBasic knowledge of different types of cables- PVC, APVC. General practical knowledge of laying ca bles direct in ground, in troughs and in pipes, handling, bending, jointing, plumbing. Underground and above junction boxes. Distribution boxes and pillars, joint box compounds, melting of compounds, filling boxes with compounds. Part-8 UNDERGROUND CABLES FOR VOLTAGE UP TO 33,000 VOLTS Basic knowledge of differ ent types of ca bles – AYFY, XLPE, oil filled, gas filled and any other types. Current rating – short time rating and continuous rating. Calculation of voltage drop. Aluminium a nd copper cable jointing- types, precautions, termination. I.S. Regulations regar ding cables. Part-9 INSTALLATIONS NOT EXCEEDING 33,000 VOLTS1.Switch Gear and Protection: Knowledge of various types of switches, protective fuses, circuit breakers- OCB, VCB, ACB, MCCB, MCB, SF 6 Breakers. Over cur rent, earth fa ult and earth leakage relays and their settings. HRC fuses, paper barrel and fuses – use and construction. Lightning Arresters, isolators, bus bar, D.O. cum Ga ng Switch, hook stick. Earthing of sub-stations. 2.Transformers: Transformers- construction, use and maintenance. Voltage and current relation. Three phase transformer connections- Star/Star, Delta/Delta, Star/Delta, Delta/Star. Transformer tappings. 3.Instrument Transformers: Curr ent transformers, CT specifica tion. P otential Transformers, PTs. 4.Energy Measurements: Measurement of power, Watt meters, Energy meters, Trivector meters. Computation of energy. 5.Clearances: Statutory clearance of live parts from ground. Sectional clearance, equipment clearance. Clear ance of oil cont aining equipment. Ex-62/201724 Part – 10 VOLTAGE RANGE : EXCEEDING 33,000 VOLTS. Types of installation :Overhead lines and installa tions at voltages exceeding 33,000 volts. 1.General: Knowledge of conductors, supports, cross arms, insulators and other line accessories used in H.T.line cons tructions, application and uses, making bills of ma terials. Basic knowledge of common types and rating of transformers used in power supply system-types, ratings and use of common sub- station equipments such as isolators, circuit breakers, distribution pillars, lightning arrestors, bushing for transformers a nd other equipment –CTs and PTs. 2.Construction: Methods of construction of overhead lines exceeding 33, 000 volts, conductor, jointing, jumpering and knowledge of configura tion of conductors, clearances, sag, spans etc. erection of poles and floor mounted transformer and associated sub-station equipment, installation of circu it breakers, isola tor s. 3.Service connection at high voltage : Use and installation of CTs & PTs for high pressure metering. 4.Testing : Methods of testing overhead lines and sub-station equipment, fault testing, location and rectifica tion. 5.Earthing : Knowledge of pract ice and procedures for H.T. overhead line equipment and sub-stations. 6.Working procedure : Line cleara nce procedures- safe working pra ctice for high volt age over head lines insta lla tion. Intimate knowledge of Electrical shock t reatment methods and procedures. 7.Maintenance : Methods of maintenance of overhead lines, sub-station, sub-sta tion equipment, transformer -oil, test ing and filtration. 8.Regulations and Code of practice: Familiar ity with the relevant Central Electricity Authority (Measur es relating to Safety and Electric Supply) Regulations, 2010 and National Codes of practice, R.E.C. standards and code of practice.Ex-62/2017 25 ANNEXURE-IV FORMS FORM-A [See regulation 15] APPLICATION FOR ELECTRICAL CONTRACTOR’S LICENCE (For new Licence/Special Class/Increase in scope of work) 1.Name of fir m in which an Electr ical: …………………………………………… Contractor ’s License is applied 2.Business a ddress with phone number: ………………………………………..…. …………………………………….…….. 3.Full name of the proprietor: ……………………………………….….. (in capital lett ers) 4.Home address with phone number: …….………………………………..….... …………………………………………… 5.Date of Birth of proprietor: Date………. Month …….… Year………. (Attested photocopy to be enclosed for Proof of a ge) 6.Class of License applied for: ……………………………………………. Class-I or II/Special Class 7.Previous License No., if any:…………………………………………….. 8.a)Existing class of work ……………………………………………. b)Increase in scopes of work applied for ………………………………...…………. 9.For Special Class Electrical Contractor’s License only a) Name and location of work for which the License is applied for : …….……………………………………… b) Expected duration of completion of the work ……………………………………….. c) Duration / period for which License is required …………………………………..... 10. Deta ils of Electrica l Supervisors holding : 1)Name ………………………………… valid certificate in theCertificate No………………………..… employ of the applicantDate of expiry:………………………… 11. Deta ils of Electrica l Workmen holding : 1)Name:…………………………………... valid permit in the sole and wholePermit Number:………………………… time employ of the applicantDate of expiry:………………………….. 2)Name:…………………………………... Permit Number:…….………………… Date of expiry:………………………......…Recent passport size photo Ex-62/201726 12. Paid Rs ……….… vide receipt No……...…….. Dt……/...../… to the Secretary 13.Instrument in my possess ion are as follows: Sl. NoName of instr umentMaker’s nameSerial numberRemar ks 12345 I……………………………………….hereby declare that the particulars stated above are correct to best of my knowledge. I fully understand the Terms and Conditions under which a n Electrical C ontract or ’s License is granted, a breach of which will render the license liable to cancellation. Signature Date ……………………………Name:……………………… Note: 1)The applicant shall submit attested photocopy of Voters ID Card/Electricity Bill/ Telephone Bill/ Bank Pass Book/Ration card for proof of addr ess. 2)Any person who make or assist in making false representation for the purpose of obtaining an Electrical C ontract or ’s License himself is liable to be prosecuted. 3)Two copies of recent passport size photographs of the a pplicant should accompany the applica tion DECLARATION BY ELECTRICAL SUPERVISORThis is to declare that I (name in capital letters) …………………………………………… holding valid Electrical Supervisor ’s Certificate No …………………………is not regular/work-charged/officiating/ cont ract/ muster roll employee of any Government Department/undertaking or regular or full t ime employee of any company or firm. I am willing to work under (name or firm)s…………………………………...…as an Electrical Supervisors. Signature Date:…………………Full name……………………………………. DECLARATION BY ELECTRICAL WORKMANThis is to declare that I (name in capital letters) ……………………………………………… holding valid Elect rical Workman Permit No……………………………. is not a regular/work-charged/contr act/ muster roll employee of a ny Government department/Undertaking or a regular or full time employee of any company or firm. I am willing to work under (name of firm) M/s……………………………..……as an Electrical Workman. Signature Date………………..Full Name…………………………………….Ex-62/2017 27 FORM-B [See regulation 29 (1)] APPLICATION FOR ELECTRICAL SUPERVISOR’S CERTIFICATE EXAMINATION 1.Full name of the applicant (in capital letters):……………..………………. 2.Father’s name:……………………………… 3.Date of birth: Date…....... Month ........… Year…....… 4.Perma nent address in full:.……………………………… with phone no……………………………….. 5.Present addr ess in full with phone no.:……………………………… 6.Deta ils of technical qua lifica tion:………………………………. 7.Fees payable: 1) Initial fee – Rs. 500.00 2) Examination fee Rs.150 for each class: Receipt No…...........dt…............. 8.Class for Examina tion:………………………………. I hereby declare that the particulars stated a bove ar e correct and true to the best of my knowledge and believe. Date…………………. Signature of Applicant Note: 1)Attested cop y of document showing date of birth should b e submitted with the a pplication. 2)Attested copy of the technical qualification to be submitted with t he application. 3)Original copy of the certificate should be produced at the time of interview. 4)Two copies of recent passport size photographs of the applicant with name and signature on the back should accompa ny the application. 5)Any person making false statement shall render himself liable for prosecution. 6)Selected Ca ndidates will have to pay initial fee for obtaining Supervisor ’s C ertificate. INCOMPLETE APPLICATION WILL BE REJECTED.Recent passport size photoEx-62/201728 FORM-C [See regulation 32 (1)] APPLICATION FOR ELECTRICAL WORKMAN’S PERMIT EXAMINATION 1. Full name of the applicant (in capital letters) :…………….……………………….… 2. Father’s name:…………..………………………..….. 3. Date of birth: Date…………Month…….. Year……. 4. P ermanent address in full with phone no:……………………………….……….. 5. P resent address in full with phone no.:………………………………….……... 6. Details of technical qualifica tion:…………………………………………. 7. Fees payable :1) Initial fee – Rs.350.00 2) Examination fee Rs.100 for each class Receipt No……….. dt. ………….... 8. Class for Examination :……….……… I hereby declare that the particulars stated above are corr ect and true to the best of my knowledge and believe. Date…………………. Signature of Applicant Note: 1)Attested cop y of document showing date of birth should b e submitted with the a pplication. 2)Attested cop y of the technical qua lification to be submitted with the application. 3)Original copy of the certificate should be produced at the time of interview. 4)Two copies of recent passport size photographs of the applica nt with name and signa ture on the back should accompa ny the application. 5)Any person making false statement shall render himself liable for prosecution. 6)Selected Ca ndidates will have to pay initial fee for obtaining Supervisor ’s C ertificate. INCOMPLETE APPLICATION WILL BE REJECTED.Recent passport size photoEx-62/2017 29 Form D (See Regulation 16) Sample of Electrical Contractor’s Licence Front Page GOVERNMENT OF MIZORAM MIZORAM ELECTRICAL LICENSING BOARD ELECTRICAL CONTRACTOR’S LICENSE No. MELB/C-……/………./…… Firm : ……………………… Pr opr ietor : ……………………. Date of birth : …………../……./………….. Address :………………………………. Valid up to : ……./………../20……. Back page CLASS AUTHORISED TO WORK Secretary MIZORAM ELECTRICAL LICENSING BOARDRecent passport size photo withNote :- In case of new Electrical C ontract or License, Secretary will issue after obtaining approval of the Chairman through file.Ex-62/201730 Form E [see regulation 30 (1)] Sample of Electrical Supervisor’s Certificate Front Page GOVERNMENT OF MIZORAM MIZORAM ELECTRICAL LICENSING BOARD ELECTRICAL SUPERVISOR’S CERTIFICATE MELB No …. /S/……/….. Name:................................................. Date of birth:........................./.........../.................... Address:.......................................................... Valid up to:.............../................./20.................. . Back page CLASS AUTHORISED TO WORK Secretary MIZORAM ELECTRICAL LICENSING BOARDRecent passport size photo with signatureEx-62/2017 31 Form F [see regulation 33 (1)] Sample of Electrical Workman’s Permit Front Page GOVERNMENT OF MIZORAM MIZORAM ELECTRICAL LICENSING BOARD ELECTRICAL WORKMAN’S PERMIT N0.MELB …../W/……/…… Name: ……………………… Date of birth : …………../……./………….. Address:………………………………. Valid up to: ……./………../20……. Back page CLASS AUTHORISED TO WORK Secretary MIZORAM ELECTRICAL LICENSING BOARDRecent passport size photo signatureEx-62/201732 Form G [see regulation 32(1)(ii)] Certificate to be granted to Electrical Staff for admission to Electrical Workman’s and Electrical Supervisor ’s examination. 1.Name of Employee ( in capital letters ) : 2.Date of Employment: 3.Date of discharge, if discha rged : 4.Nature or Work in which engaged : 5.Skill in t he work in which engaged: 6.Conduct : 7.General Remarks : I here by declare that the particulars stated a bove ar e correct and true to the best of my knowledge. Date:……………Signature of Employee / Licensed Electrical Contractor Seal Note :- 1)This Certificate should b e granted only to persons who are or have been actually employed on Electrical Wiring and installation works and whose names are entered in the regist er of wiring staff in F orm - H mainta ined by every Licensed Electrical Contractor. 2)Issue of false Certificate will render the Licensed Electrical C ontract or and t he person concerned liable for a ction a gainst them. 3)The employer or the Licensed Electrica l Contractor shall, if required by the Secretary, be responsible for producing docu mentary evidence regar ding the applicant’s employment.Ex-62/2017 33 Form-H [See regulation 19] Detail of Electrical Supervisor, Workman & Apprentices Name of Contractor : License No : Period from Dt. ……./……./……. to Dt. ......../……../… Sl.NoNamePermit/Date ofDate ofRemar ks ofCertificateEmploymentDischarge EmployeeNumber if any 1 2 3 4 5 6 Place: ..................................Signature of Contra ctor Date............/………/……...SealEx-62/201734 Form –I Return of Work Done [See regulation 19] Name of Contractor : License No : Period from Dt. ....................... to Dt. ...................... Sl.No Name of workName ofName ofDate ofTotalTest r epor t with address/supervisor withWorkmanCom- LoadSubmitted to locationcertificate NoWith permit pletion No 1234567 Place :…………………………Signature of contra ctor Date : ……./……………./…SealEx-62/2017 35 Form J [See Regulation 18 (1)] APPLICATION FOR RENEWAL OF ELECTRICAL CONTRACTOR’S LICENCE 1. Name of Applicant ( in Capital ): ...................................................... 2. Detail Address with phone Number: ....................................................... 3. Name of firm: ....................................................... 4. License Number: .......................................................... 5. Date of Expiry: ........................................................... 6. Name of Supervisor with Certificate no: ........................................................... 7. Name of Workma n with permit Nos.: …….................................................... 8. Renewa l fee: (as per Schedu le of fees):………………….. 9. Late Renewal fee, if any (as per Schedule of fees) ……………. 10. Enclosures: 1. Form - H. List of employee 2. F orm – I. Return of Work Done Date ..................................Signature of Contra ctor SealRecent passport size photo signature Ex-62/201736 Form – K Notice before Commencement of works [See Regulation 23(b)] Work Sl/no : ...................................... Date : ......................... 1.Name of Contr actor: ................................... 2.License no: .................................... 3.Detail of wor k to be done: ................................... ( Attach electrical Drawing ) 4.Full address work to be done: ....................................... ....................................... ....................................... ...................................... 5.Tentative da te of starting work: ...................... 6.Expected date of completion of the work: ....................... 7.Name of supervisor with certificate No: ...................... 8.Names of wor kman with permit no: ...................... Date ........./........../......…Signature of Contra ctor with seal. Note:- The contr act or shall submit copy of this Notice befor e commencement of work to the S.D. O. (P&E) concerned, the Electrical Inspector and the Secretary M. E.L.B. whenever a new work is taken up by him except for I phase and III phase internal wiring of load up to 20 KW. Notice for internal wiring works up to 20 kW load maybe given to the S.D.O. (P&E ) concerned only.Ex-62/2017 37 FORM – L [see regulation 31(1), 34(1)] APPLICATION FOR RENEWAL OF SUPERVISOR’S CERTIFICATE & WORKMAN’S PERMIT 1.Name of Applicant(in capital letters) :___________________________ 2.Deta il Address with phone number : ___________________________ ____________________________ 3.Certificate/Permit Number :____________________________ 4.Date of Expiry :Dt___/_____/____ 5.Present occupation with Address:_____________________________ :_____________________________ :_____________________________ 6.Renewal fee ( as per Schedule of fees )_________________ 7.Late renewal fee, if any ( as per Schedule of fees )____________ Date:______________Signature of ApplicantRecent passport size photo signature Published and Issued by the Controller, Printing & Stationery, Mizoram Printed at the Mizoram Government Press, Aizawl C-50Ex-62/201738The Governor of Mizoram is pleased to rename the Review and Evaluation Committee to study the impact of the Mizoram Liquor Prohibition and Control Act, 2014 as the “State Prohibition Council (SPC)” for Mizoram with immediate effect
The Mizoram Gazette EXTRA ORDINARY Published by Authority RNI No. 27009/1973 Postal Regn. No. NE-313(MZ) 2006-2008VOL - XLVI Aizawl, Friday 17.3.2017 Phalguna 26, S.E. 1938, Issue No. 115 NOTIFICATIONNo.J.25011/8/2016-EXC, the 10th March, 2017.In partial modification of this Department Notifi- cation of even No. Dt.15.7.2016 and in exercise of the power confer by Sub-section(l) of Section 81 of MLPC Act, 2014, the Governor of Mizoram is pleased to rename the Review and Evaluation Committee to study the impact of the Mizoram Liquor Prohibition and Control Act, 2014 as the “State Prohibition Coun- cil (SPC)” for Mizoram with immediate effect and until further orders. The Dignitaries, Officials and Non- Officia l members remain the same. The main purpose of the State Prohibition Council (SPC) will be to study the impact, review and to eva luate the effect of the Mizora m Liquor Pr ohibit ion a nd C ontr ol Act, 2014. T he terms of r eference shall be: i)Economical and Social aspect. ii)Health aspect. iii)Review of the enfor cement of the MLPC Act/Rules, 2014. DIGNITARIES1.Minister, Excise & Narcotics Department etc.-Chair man. 2.Parl. Secretary, Excise & Narcotics Department-Vice Chairman. OFFICIALS1.Commissioner & Secretary,-Member Secretary. Excise & Narcotics Department etc. 2.Commissioner of Excise Narcotics, Mizoram-Member. 3.Superintendent of Police, Aizawl District-Member. 4.Deputy Secretary, Excise Narcotics Department-Member. 5.Deputy Commissioner of Excise & Narcotics (Enf.)-Member. 6.Deputy Secretary, Law & Judicia l Department-Member. 7.Under Secretary, Excise Narcotics Department-Member. 8.Assistant Commissioner of Excise & Narcotics (Enf.)-Member. 9.Superintendent of Excise & Narcotics, Aizawl District-Member. NON OFFICIALS1.Upa Prof. Lianzela.-Member. 2.Dr. Lalchhuanawma Tochhawng.-Member. 3.Dr. Lalbiakzuala.-Member. 4.Dr. C. Lalhrekima.-Member. 5.Dr. Laldinliana Varte.-Member. 6.Rev. Lalengkima-Member. 7.Upa J.H. Ramnghinlova.-Member. 8.Pu Dominic Lalhmangaiha.-Member. 9.Pu K.L. Liana.-Member. 10.Upa R.K. Thanga.-Member. 11.Upa Lalbiakzuala.-Member. 12.Pu Vanlalrema Vantawl.-Member. 13.Upa Prof. C. Lalkima.-Member. 14.Rev. Dr. K.Lalrinthanga.-Member. 15.Rev. R. Lalrinsanga.-Member. 16.Lt. Col. (SA) Lalramhluna.-Member. 17.Pu Lalnunkunga Sailo.-Member. Benjamina, Commissioner & Secretary to the Govt. of Mizoram, Excise & Narcotics Department. Published and Issued by the Controller, Printing & Stationery, Mizoram Printed at the Mizoram Government Press, Aizawl C-50Ex-115/20172
The Mizoram Gazette EXTRA ORDINARY Published by Authority RNI No. 27009/1973 Postal Regn. No. NE-313(MZ) 2006-2008VOL - XLVI Aizawl, Friday 17.3.2017 Phalguna 26, S.E. 1938, Issue No. 115 NOTIFICATIONNo.J.25011/8/2016-EXC, the 10th March, 2017.In partial modification of this Department Notifi- cation of even No. Dt.15.7.2016 and in exercise of the power confer by Sub-section(l) of Section 81 of MLPC Act, 2014, the Governor of Mizoram is pleased to rename the Review and Evaluation Committee to study the impact of the Mizoram Liquor Prohibition and Control Act, 2014 as the “State Prohibition Coun- cil (SPC)” for Mizoram with immediate effect and until further orders. The Dignitaries, Officials and Non- Officia l members remain the same. The main purpose of the State Prohibition Council (SPC) will be to study the impact, review and to eva luate the effect of the Mizora m Liquor Pr ohibit ion a nd C ontr ol Act, 2014. T he terms of r eference shall be: i)Economical and Social aspect. ii)Health aspect. iii)Review of the enfor cement of the MLPC Act/Rules, 2014. DIGNITARIES1.Minister, Excise & Narcotics Department etc.-Chair man. 2.Parl. Secretary, Excise & Narcotics Department-Vice Chairman. OFFICIALS1.Commissioner & Secretary,-Member Secretary. Excise & Narcotics Department etc. 2.Commissioner of Excise Narcotics, Mizoram-Member. 3.Superintendent of Police, Aizawl District-Member. 4.Deputy Secretary, Excise Narcotics Department-Member. 5.Deputy Commissioner of Excise & Narcotics (Enf.)-Member. 6.Deputy Secretary, Law & Judicia l Department-Member. 7.Under Secretary, Excise Narcotics Department-Member. 8.Assistant Commissioner of Excise & Narcotics (Enf.)-Member. 9.Superintendent of Excise & Narcotics, Aizawl District-Member. NON OFFICIALS1.Upa Prof. Lianzela.-Member. 2.Dr. Lalchhuanawma Tochhawng.-Member. 3.Dr. Lalbiakzuala.-Member. 4.Dr. C. Lalhrekima.-Member. 5.Dr. Laldinliana Varte.-Member. 6.Rev. Lalengkima-Member. 7.Upa J.H. Ramnghinlova.-Member. 8.Pu Dominic Lalhmangaiha.-Member. 9.Pu K.L. Liana.-Member. 10.Upa R.K. Thanga.-Member. 11.Upa Lalbiakzuala.-Member. 12.Pu Vanlalrema Vantawl.-Member. 13.Upa Prof. C. Lalkima.-Member. 14.Rev. Dr. K.Lalrinthanga.-Member. 15.Rev. R. Lalrinsanga.-Member. 16.Lt. Col. (SA) Lalramhluna.-Member. 17.Pu Lalnunkunga Sailo.-Member. Benjamina, Commissioner & Secretary to the Govt. of Mizoram, Excise & Narcotics Department. Published and Issued by the Controller, Printing & Stationery, Mizoram Printed at the Mizoram Government Press, Aizawl C-50Ex-115/20172The Review and Evaluation Committee of the MLPC Act, 2014 has been renamed as “The State Prohibition Council”
The Mizoram Gazette EXTRA ORDINARY Published by Authority RNI No. 27009/1973 Postal Regn. No. NE-313(MZ) 2006-2008VOL - XLVI Aizawl, Friday 17.3.2017 Phalguna 26, S.E. 1938, Issue No. 116 NOTIFICATIONNo.J.25011/8/2016-EXC, the 10th March, 2017.In the interest of Pubic Services and on the ad- vice of the Review and Evaluation Committee of the MLPC Act, 2014 in its first meeting held on the 9.8.2016, the Governor of Mizoram is pleased to constitute a“Study Group” of MLPC Act, 2014 to study the Socio-economic impacts and to evaluate the effect of the Mizoram Liquor Prohibition and Control Act, 2014 with immediate effect and until further orders. It may be mentioned here that the Review and Evaluation Committee of the MLPC Act, 2014 has been rena med a s“The State Prohibition Council” as per Sub-section (1) of Section 81 of the MLPC Act, 2014 vide this Department’s Notification of even No.Dt.10.3.2017(copy enclosed). The Study Group will consist of the following members : 1.Pu Dominic Lalhmangaiha-Member (C onvener). 2.Lt. Col. (SA) Lalramhluna-Member. 3.Dr. Laldinliana Varte (MZU) -Member. 4.Dr. Lalbiakzuala (Surgeon)-Member. 5.Dr. Lalhrekima-Member. 6.Upa Lalbiakzuala-Member. 7.Pu Vanlalrema Vantawl-Member. In addition to the above members, Under Secretary to the Government of Mizoram Excise & Nar- cotics Department may provide necessary secretarial/logistic assistance to the Study Group as required. A sum of Rs. 5,00,000/- (Rupees five lakhs) only is initially earmarked for the Study Group to meet incidental expenditures. Members of the Study Group may be allowed to visit other States in connection with their study if they so desire. Benjamina, Commissioner & Secretary to the Govt. of Mizoram, Excise & Narcotics Department. Published and Issued by the Controller, Printing & Stationery, Mizoram Printed at the Mizoram Government Press, Aizawl C-50
The Mizoram Gazette EXTRA ORDINARY Published by Authority RNI No. 27009/1973 Postal Regn. No. NE-313(MZ) 2006-2008VOL - XLVI Aizawl, Friday 17.3.2017 Phalguna 26, S.E. 1938, Issue No. 116 NOTIFICATIONNo.J.25011/8/2016-EXC, the 10th March, 2017.In the interest of Pubic Services and on the ad- vice of the Review and Evaluation Committee of the MLPC Act, 2014 in its first meeting held on the 9.8.2016, the Governor of Mizoram is pleased to constitute a“Study Group” of MLPC Act, 2014 to study the Socio-economic impacts and to evaluate the effect of the Mizoram Liquor Prohibition and Control Act, 2014 with immediate effect and until further orders. It may be mentioned here that the Review and Evaluation Committee of the MLPC Act, 2014 has been rena med a s“The State Prohibition Council” as per Sub-section (1) of Section 81 of the MLPC Act, 2014 vide this Department’s Notification of even No.Dt.10.3.2017(copy enclosed). The Study Group will consist of the following members : 1.Pu Dominic Lalhmangaiha-Member (C onvener). 2.Lt. Col. (SA) Lalramhluna-Member. 3.Dr. Laldinliana Varte (MZU) -Member. 4.Dr. Lalbiakzuala (Surgeon)-Member. 5.Dr. Lalhrekima-Member. 6.Upa Lalbiakzuala-Member. 7.Pu Vanlalrema Vantawl-Member. In addition to the above members, Under Secretary to the Government of Mizoram Excise & Nar- cotics Department may provide necessary secretarial/logistic assistance to the Study Group as required. A sum of Rs. 5,00,000/- (Rupees five lakhs) only is initially earmarked for the Study Group to meet incidental expenditures. Members of the Study Group may be allowed to visit other States in connection with their study if they so desire. Benjamina, Commissioner & Secretary to the Govt. of Mizoram, Excise & Narcotics Department. Published and Issued by the Controller, Printing & Stationery, Mizoram Printed at the Mizoram Government Press, Aizawl C-50